Predicting actual crack size through crack signal obtained by advanced Flexible Eddy Current Sensor using ResNet integrated with CBAM and Huber loss function
Le Quang Trung , Naoya Kasai , Minhhuy Le , Kouichi Sekino
{"title":"Predicting actual crack size through crack signal obtained by advanced Flexible Eddy Current Sensor using ResNet integrated with CBAM and Huber loss function","authors":"Le Quang Trung , Naoya Kasai , Minhhuy Le , Kouichi Sekino","doi":"10.1016/j.ndteint.2024.103249","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents an advanced FEC sensor, engineered by arranging coils in a co-directional current configuration. Moreover, boasting a compact design, the FEC sensor showcases significantly enhanced spatial resolution, enabling robust detection of small cracks even at low excitation frequencies and mitigating issues of overlapping in adjacent crack detection. Results indicate successful crack detection through voltage and phase measurements, albeit with phase signals demonstrating variation at specific excitation frequencies, complicating the determination of actual crack sizes. Consequently, a novel model is proposed to forecast actual crack sizes, leveraging experimental data from the FEC sensor system. This model integrates a Residual Neural Network (ResNet) architecture with a Convolutional Block Attention Module (CBAM) and utilizes the Huber loss function to minimize errors during model training. Comparative analysis underscores the superior performance of the proposed model in predicting crack length and depth compared to the standalone ResNet, particularly when utilizing the Huber loss function with a δ value of 1.0. Evaluation metrics, encompassing Mean Squared Error (MSE), Mean Absolute Error (MAE), and Mean Absolute Percentage Error (MAPE), illustrate an average accuracy surpassing 95 % for crack size predictions. Consequently, the proposed model demonstrates remarkable performance, significantly reducing the time required to ascertain actual crack sizes by leveraging voltage and phase measurements.</div></div>","PeriodicalId":18868,"journal":{"name":"Ndt & E International","volume":"149 ","pages":"Article 103249"},"PeriodicalIF":4.1000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ndt & E International","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0963869524002147","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0
Abstract
This study presents an advanced FEC sensor, engineered by arranging coils in a co-directional current configuration. Moreover, boasting a compact design, the FEC sensor showcases significantly enhanced spatial resolution, enabling robust detection of small cracks even at low excitation frequencies and mitigating issues of overlapping in adjacent crack detection. Results indicate successful crack detection through voltage and phase measurements, albeit with phase signals demonstrating variation at specific excitation frequencies, complicating the determination of actual crack sizes. Consequently, a novel model is proposed to forecast actual crack sizes, leveraging experimental data from the FEC sensor system. This model integrates a Residual Neural Network (ResNet) architecture with a Convolutional Block Attention Module (CBAM) and utilizes the Huber loss function to minimize errors during model training. Comparative analysis underscores the superior performance of the proposed model in predicting crack length and depth compared to the standalone ResNet, particularly when utilizing the Huber loss function with a δ value of 1.0. Evaluation metrics, encompassing Mean Squared Error (MSE), Mean Absolute Error (MAE), and Mean Absolute Percentage Error (MAPE), illustrate an average accuracy surpassing 95 % for crack size predictions. Consequently, the proposed model demonstrates remarkable performance, significantly reducing the time required to ascertain actual crack sizes by leveraging voltage and phase measurements.
期刊介绍:
NDT&E international publishes peer-reviewed results of original research and development in all categories of the fields of nondestructive testing and evaluation including ultrasonics, electromagnetics, radiography, optical and thermal methods. In addition to traditional NDE topics, the emerging technology area of inspection of civil structures and materials is also emphasized. The journal publishes original papers on research and development of new inspection techniques and methods, as well as on novel and innovative applications of established methods. Papers on NDE sensors and their applications both for inspection and process control, as well as papers describing novel NDE systems for structural health monitoring and their performance in industrial settings are also considered. Other regular features include international news, new equipment and a calendar of forthcoming worldwide meetings. This journal is listed in Current Contents.