Yu Wang , Xiaofen Liu , Yan Chen , Beining Guo , Jiao Liu , Jing Zhang
{"title":"Rapid quantification of polymyxin B in human pulmonary epithelial lining fluid by LC-MS/MS and its clinical application","authors":"Yu Wang , Xiaofen Liu , Yan Chen , Beining Guo , Jiao Liu , Jing Zhang","doi":"10.1016/j.jchromb.2024.124332","DOIUrl":null,"url":null,"abstract":"<div><div>Pulmonary epithelial lining fluid (ELF) was commonly used for the pharmacokinetic study in lower respiratory tract infections. To characterize the intrapulmonary pharmacokinetic properties of polymyxin B following aerosol delivery, we developed and fully validated a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantifying polymyxin B in human bronchoalveolar lavage fluid (BALF). The ELF concentrations were calculated by the BALF values of polymyxin B using urea as a volume normalizer. Chromatographic separation was achieved on a Phonomenex Kinetex XB-C18 column(100 mm × 2.1 mm I.D., 2.6 μm)in acetonitrile and water both containing 0.2 % formic acid. The flow rate was set as 0.4 mL/min for a 3.5 min running time. Protein precipitation was used in preparing BALF samples with polymyxin E1 as an internal standard. Polymyxin B was detected under multiple reaction monitoring conditions using the electrospray ionization interface running in the positive ionization mode. The assay showed a good linear relationship over the tested concentration ranges of 0.0300/0.00306–––10.0/1.02 mg/L for polymyxin B1/B2 in bronchoalveolar lavage fluid (R<sup>2</sup> > 0.99). The inter- and inter-day precisions (RSD, %) were < 12.2 %(15.2 % for LLOQ samples)and the accuracies (%) were within the range of 94.3 ∼ 110.4 %. This reliable LC–MS/MS method for detection of polymyxin B was successfully applied to conduct a pulmonary penetration study in patients following aerosol administration.</div></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1247 ","pages":"Article 124332"},"PeriodicalIF":2.8000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224003416","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Pulmonary epithelial lining fluid (ELF) was commonly used for the pharmacokinetic study in lower respiratory tract infections. To characterize the intrapulmonary pharmacokinetic properties of polymyxin B following aerosol delivery, we developed and fully validated a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantifying polymyxin B in human bronchoalveolar lavage fluid (BALF). The ELF concentrations were calculated by the BALF values of polymyxin B using urea as a volume normalizer. Chromatographic separation was achieved on a Phonomenex Kinetex XB-C18 column(100 mm × 2.1 mm I.D., 2.6 μm)in acetonitrile and water both containing 0.2 % formic acid. The flow rate was set as 0.4 mL/min for a 3.5 min running time. Protein precipitation was used in preparing BALF samples with polymyxin E1 as an internal standard. Polymyxin B was detected under multiple reaction monitoring conditions using the electrospray ionization interface running in the positive ionization mode. The assay showed a good linear relationship over the tested concentration ranges of 0.0300/0.00306–––10.0/1.02 mg/L for polymyxin B1/B2 in bronchoalveolar lavage fluid (R2 > 0.99). The inter- and inter-day precisions (RSD, %) were < 12.2 %(15.2 % for LLOQ samples)and the accuracies (%) were within the range of 94.3 ∼ 110.4 %. This reliable LC–MS/MS method for detection of polymyxin B was successfully applied to conduct a pulmonary penetration study in patients following aerosol administration.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.
Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.