{"title":"Enhanced electrochemiluminescence of CdS QDs encapsulated in IRMOF-3 for sensitive detection of human epithelial protein 4.","authors":"Xinyu Liu, Dongyu Han, Feng Jiang, Shanghua Liu, Yueyuan Li, Zhen Xu, Qing Liu, Yueyun Li, Qin Wei","doi":"10.1016/j.talanta.2024.127052","DOIUrl":null,"url":null,"abstract":"<p><p>The advancement of pragmatic and highly-sensitive electrochemiluminescence (ECL) biosensors depends upon signal tags with high and stable signal intensity. Herein, enhanced ECL emission was obtained by encapsulating the dual-stabilizer-capped CdS QDs in a metal-organic framework (MOF), which served as a valid ECL signal tag for detecting biomarkers. Dual-stabilizer-capped CdS QDs reduce dangling bonds on the surface and improved the ECL emission. Furthermore, functionalized isoreticular metal-organic framework-3 (IRMOF-3) can not only load a large quantity of CdS QDs through the encapsulation capability but also serves as a co-reaction accelerator to promote the formation of more SO<sub>4</sub><sup>•-</sup> from the S<sub>2</sub>O<sub>8</sub><sup>2-</sup>, further improving the ECL emission of QDs, while the integrated design of IRMOF-3 co-reaction accelerator and CdS QDs effectively shortens the electron transfer pathway and reduces the energy consumption in ECL system. Using human epithelial protein 4 (HE4) as the model of analysis, the biosensor demonstrated a broad linear range (50 fg mL<sup>-1</sup>∼50 ng mL<sup>-1</sup>) and a low detection limit (9.89 fg mL<sup>-1</sup>) under optimal operating conditions. The study provides an effective and alternative method to improve the ECL efficiency of QDs, significantly broadening their potential applications in sensing analysis, medical diagnostics, and bioimaging.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"282 ","pages":"127052"},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127052","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The advancement of pragmatic and highly-sensitive electrochemiluminescence (ECL) biosensors depends upon signal tags with high and stable signal intensity. Herein, enhanced ECL emission was obtained by encapsulating the dual-stabilizer-capped CdS QDs in a metal-organic framework (MOF), which served as a valid ECL signal tag for detecting biomarkers. Dual-stabilizer-capped CdS QDs reduce dangling bonds on the surface and improved the ECL emission. Furthermore, functionalized isoreticular metal-organic framework-3 (IRMOF-3) can not only load a large quantity of CdS QDs through the encapsulation capability but also serves as a co-reaction accelerator to promote the formation of more SO4•- from the S2O82-, further improving the ECL emission of QDs, while the integrated design of IRMOF-3 co-reaction accelerator and CdS QDs effectively shortens the electron transfer pathway and reduces the energy consumption in ECL system. Using human epithelial protein 4 (HE4) as the model of analysis, the biosensor demonstrated a broad linear range (50 fg mL-1∼50 ng mL-1) and a low detection limit (9.89 fg mL-1) under optimal operating conditions. The study provides an effective and alternative method to improve the ECL efficiency of QDs, significantly broadening their potential applications in sensing analysis, medical diagnostics, and bioimaging.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.