Experimental characterization of an isoplanatic patch in mouse cortex using adaptive optics.

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Biomedical optics express Pub Date : 2024-09-04 eCollection Date: 2024-10-01 DOI:10.1364/BOE.527313
Jean Commère, Marie Glanc, Laurent Bourdieu, Raphaël Galicher, Éric Gendron, Gérard Rousset
{"title":"Experimental characterization of an isoplanatic patch in mouse cortex using adaptive optics.","authors":"Jean Commère, Marie Glanc, Laurent Bourdieu, Raphaël Galicher, Éric Gendron, Gérard Rousset","doi":"10.1364/BOE.527313","DOIUrl":null,"url":null,"abstract":"<p><p>Optical microscopy techniques have become essential tools for studying normal and pathological biological systems. However, in many situations, image quality deteriorates rapidly in the field of view due to optical aberrations and scattering induced by thick tissues. To compensate for these aberrations and restore the microscope's image quality, adaptive optics (AO) techniques have been proposed for the past 15 years. A key parameter for the AO implementation lies in the limited isoplanatic dimension over which the image quality remains uniform. Here, we propose a method for measuring this dimension and deducing the anisoplanatism and intensity transmission of the samples. We apply this approach to fixed slices of mouse cortices as a function of their thickness. We find a typical mid-maximum width of 20 µm for the isoplanatic spot, which is independent of sample thickness.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 10","pages":"5645-5659"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482162/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.527313","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Optical microscopy techniques have become essential tools for studying normal and pathological biological systems. However, in many situations, image quality deteriorates rapidly in the field of view due to optical aberrations and scattering induced by thick tissues. To compensate for these aberrations and restore the microscope's image quality, adaptive optics (AO) techniques have been proposed for the past 15 years. A key parameter for the AO implementation lies in the limited isoplanatic dimension over which the image quality remains uniform. Here, we propose a method for measuring this dimension and deducing the anisoplanatism and intensity transmission of the samples. We apply this approach to fixed slices of mouse cortices as a function of their thickness. We find a typical mid-maximum width of 20 µm for the isoplanatic spot, which is independent of sample thickness.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用自适应光学技术对小鼠皮层中的等平面斑块进行实验鉴定。
光学显微镜技术已成为研究正常和病理生物系统的重要工具。然而,在许多情况下,由于厚组织引起的光学像差和散射,视场中的图像质量会迅速下降。为了补偿这些像差并恢复显微镜的图像质量,自适应光学(AO)技术在过去的 15 年中不断被提出。实施自适应光学技术的一个关键参数在于图像质量保持一致的有限等平面尺寸。在此,我们提出了一种测量该维度并推导出样品的异面性和强度传输的方法。我们将这种方法应用于小鼠皮层的固定切片,并将其作为厚度的函数。我们发现等平面光斑的典型中间最大宽度为 20 µm,与样本厚度无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
期刊最新文献
Super resolution reconstruction of fluorescence microscopy images by a convolutional network with physical priors. Physics-guided deep learning-based real-time image reconstruction of Fourier-domain optical coherence tomography. On bench evaluation of intraocular lenses: performance of a commercial interferometer. Predictive coding compressive sensing optical coherence tomography hardware implementation. Development of silicone-based phantoms for biomedical optics from 400 to 1550 nm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1