{"title":"Implantable loop recorder via subscapular approach in 2.7 kg neonate.","authors":"Ashley Wong, Daniel Cortez","doi":"10.1080/14796678.2024.2406111","DOIUrl":null,"url":null,"abstract":"<p><p>Implantable loop records allow continuous heart rhythm monitoring with the ability to be stored and viewed remotely. The limited use in the pediatric population stems from the unknown indications of use and feasibility of implantation. We describe the case of a 2.7kg female with Long QT3. A loop recorder helped identify breakthrough tachycardia and helped her transition to the next stage of care. Placement was at the left subscapular region with no complications. Implantable loop recorder placement is achievable in a 2.7 kg patient at corrected gestational age 38 weeks for LQT3 syndrome monitoring and management.</p>","PeriodicalId":12589,"journal":{"name":"Future cardiology","volume":" ","pages":"689-693"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11552473/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14796678.2024.2406111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Implantable loop records allow continuous heart rhythm monitoring with the ability to be stored and viewed remotely. The limited use in the pediatric population stems from the unknown indications of use and feasibility of implantation. We describe the case of a 2.7kg female with Long QT3. A loop recorder helped identify breakthrough tachycardia and helped her transition to the next stage of care. Placement was at the left subscapular region with no complications. Implantable loop recorder placement is achievable in a 2.7 kg patient at corrected gestational age 38 weeks for LQT3 syndrome monitoring and management.
期刊介绍:
Research advances have contributed to improved outcomes across all specialties, but the rate of advancement in cardiology has been exceptional. Concurrently, the population of patients with cardiac conditions continues to grow and greater public awareness has increased patients" expectations of new drugs and devices. Future Cardiology (ISSN 1479-6678) reflects this new era of cardiology and highlights the new molecular approach to advancing cardiovascular therapy. Coverage will also reflect the major technological advances in bioengineering in cardiology in terms of advanced and robust devices, miniaturization, imaging, system modeling and information management issues.