Ex Vivo Demonstration of a Novel Dual-Frequency Ultrasound Method for Quantitative Measurements of Liver Fat Content

IF 2.4 3区 医学 Q2 ACOUSTICS Ultrasound in Medicine and Biology Pub Date : 2024-10-18 DOI:10.1016/j.ultrasmedbio.2024.09.019
Sigrid Berg , Naseh Amini , Stian Solberg , Rønnaug Astri Ødegård , Bård Eirik Kulseng , Reidar Fossmark , Sébastien Muller , Simon Nitter Dankel , Rolf K. Berge , Elin Rønne , Patricia Mjønes , Rune Hansen
{"title":"Ex Vivo Demonstration of a Novel Dual-Frequency Ultrasound Method for Quantitative Measurements of Liver Fat Content","authors":"Sigrid Berg ,&nbsp;Naseh Amini ,&nbsp;Stian Solberg ,&nbsp;Rønnaug Astri Ødegård ,&nbsp;Bård Eirik Kulseng ,&nbsp;Reidar Fossmark ,&nbsp;Sébastien Muller ,&nbsp;Simon Nitter Dankel ,&nbsp;Rolf K. Berge ,&nbsp;Elin Rønne ,&nbsp;Patricia Mjønes ,&nbsp;Rune Hansen","doi":"10.1016/j.ultrasmedbio.2024.09.019","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>The rise in metabolic dysfunction–associated steatotic liver disease prevalence, closely linked with metabolic syndromes and obesity, demands accurate, cost-effective diagnostic methods for early-stage fat quantification in the liver. Here we demonstrate a novel dual-frequency ultrasound method that enables the quantitative measurement of liver fat fraction <em>ex vivo</em> and its correlation with actual fat content.</div></div><div><h3>Methods</h3><div>A total of 24 Wistar rats were divided into four different groups, where three groups were given a high-fat diet for 2, 4, and 6 wk, and the last group was given a control diet for 6 wk. Livers were imaged with ultrasound <em>ex vivo</em> in a water bath with a dual-frequency ultrasound transducer and experimental imaging protocol implemented on the Verasonics Vantage research ultrasound scanner. Ultrasound data were post-processed to estimate the non-linear bulk elasticity parameter and the liver samples were analyzed with respect to fat fraction and triglycerides.</div></div><div><h3>Results</h3><div>Rats given a high-fat diet had increased mean levels of liver fat compared with the control group. More importantly, correlation between the ultrasound-based estimation of the non-linear bulk elasticity parameter and fat fraction and triglycerides on an individual level was found to be strong (R<sup>2</sup> = 0.81, <em>p</em> = 5.8 × 10<sup>-9</sup> and R<sup>2</sup> = 0.72, <em>p</em> = 3.6 × 10<sup>-7</sup>, respectively).</div></div><div><h3>Conclusion</h3><div>This study demonstrates the potential of the novel dual-frequency ultrasound method for the quantitative measurement of liver fat fraction in excised rat livers, showing great promise for this method to become clinically relevant in the diagnosis and follow-up of patients with fatty liver disease.</div></div>","PeriodicalId":49399,"journal":{"name":"Ultrasound in Medicine and Biology","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound in Medicine and Biology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S030156292400365X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The rise in metabolic dysfunction–associated steatotic liver disease prevalence, closely linked with metabolic syndromes and obesity, demands accurate, cost-effective diagnostic methods for early-stage fat quantification in the liver. Here we demonstrate a novel dual-frequency ultrasound method that enables the quantitative measurement of liver fat fraction ex vivo and its correlation with actual fat content.

Methods

A total of 24 Wistar rats were divided into four different groups, where three groups were given a high-fat diet for 2, 4, and 6 wk, and the last group was given a control diet for 6 wk. Livers were imaged with ultrasound ex vivo in a water bath with a dual-frequency ultrasound transducer and experimental imaging protocol implemented on the Verasonics Vantage research ultrasound scanner. Ultrasound data were post-processed to estimate the non-linear bulk elasticity parameter and the liver samples were analyzed with respect to fat fraction and triglycerides.

Results

Rats given a high-fat diet had increased mean levels of liver fat compared with the control group. More importantly, correlation between the ultrasound-based estimation of the non-linear bulk elasticity parameter and fat fraction and triglycerides on an individual level was found to be strong (R2 = 0.81, p = 5.8 × 10-9 and R2 = 0.72, p = 3.6 × 10-7, respectively).

Conclusion

This study demonstrates the potential of the novel dual-frequency ultrasound method for the quantitative measurement of liver fat fraction in excised rat livers, showing great promise for this method to become clinically relevant in the diagnosis and follow-up of patients with fatty liver disease.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于定量测量肝脏脂肪含量的新型双频超声波方法的体内演示
目的:代谢功能障碍相关脂肪性肝病发病率的上升与代谢综合征和肥胖密切相关,因此需要准确、经济高效的诊断方法对肝脏进行早期脂肪定量。在此,我们展示了一种新颖的双频超声方法,该方法可实现体内肝脏脂肪分数的定量测量及其与实际脂肪含量的相关性:方法:将 24 只 Wistar 大鼠分为四组,其中三组分别给予高脂肪饮食 2、4 和 6 周,最后一组给予对照饮食 6 周。在水浴中使用双频超声换能器和在 Verasonics Vantage 研究超声扫描仪上实施的实验成像方案对肝脏进行体外超声成像。对超声波数据进行后处理,以估算非线性体积弹性参数,并分析肝脏样本中的脂肪比例和甘油三酯:结果:与对照组相比,摄入高脂肪饮食的大鼠肝脏脂肪平均水平升高。更重要的是,基于超声波估算的非线性体弹性参数与脂肪率和甘油三酯在个体水平上的相关性很强(R2 = 0.81,p = 5.8 × 10-9 和 R2 = 0.72,p = 3.6 × 10-7):这项研究证明了新型双频超声方法在定量测量切除大鼠肝脏中的肝脏脂肪率方面的潜力,并显示了该方法在诊断和随访脂肪肝患者方面的临床应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
6.90%
发文量
325
审稿时长
70 days
期刊介绍: Ultrasound in Medicine and Biology is the official journal of the World Federation for Ultrasound in Medicine and Biology. The journal publishes original contributions that demonstrate a novel application of an existing ultrasound technology in clinical diagnostic, interventional and therapeutic applications, new and improved clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and the interactions between ultrasound and biological systems, including bioeffects. Papers that simply utilize standard diagnostic ultrasound as a measuring tool will be considered out of scope. Extended critical reviews of subjects of contemporary interest in the field are also published, in addition to occasional editorial articles, clinical and technical notes, book reviews, letters to the editor and a calendar of forthcoming meetings. It is the aim of the journal fully to meet the information and publication requirements of the clinicians, scientists, engineers and other professionals who constitute the biomedical ultrasonic community.
期刊最新文献
Masthead Contents A Narrative Review of Image Processing Techniques Related to Prostate Ultrasound. Editorial Advisory Board A Review on Ultrasound-based Methods to Image the Distribution of Magnetic Nanoparticles in Biomedical Applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1