Drug-Coated Balloon Angioplasty for In-Stent Restenosis in the Vertebral Artery Ostium: Experiences From a Single Center.

Wendeng Xu, Yi Shen, Ye Wang, Bin Liang, Jian Wu, Xiaofeng Zhang
{"title":"Drug-Coated Balloon Angioplasty for In-Stent Restenosis in the Vertebral Artery Ostium: Experiences From a Single Center.","authors":"Wendeng Xu, Yi Shen, Ye Wang, Bin Liang, Jian Wu, Xiaofeng Zhang","doi":"10.1177/15385744241292115","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background and purpose:</b> Stenting appears to be a safe treatment for vertebral artery ostial stenosis (VAOS) with low complication rates and positive long-term effects. However, in-stent restenosis (ISR) after stenting is common. Drug-coated balloons (DCBs) are an effective management strategy for ISR in patients with coronary or carotid disease. In this study, we investigated the feasibility, safety, and effectiveness of DCB-assisted angioplasty for the treatment of ISR after treatment of VAOS. <b>Research Design:</b> The study included patients in the Department of Neurology at Beijing Tsinghua Changgung Hospital who underwent DCB-assisted angioplasty for ISR after previously undergoing stenting for VAOS. We retrospectively analyzed the clinical and functional outcomes in these patients. <b>Results:</b> Fourteen patients were enrolled in the study between January 2018 and April 2022. Five of the patients were female, and the mean age was 69.4 ± 7.5 years. The technical success rate was 100% and the mean operation time was 57.1 ± 29.2 minutes. No perioperative complications were reported. There were no new cases of cerebral infarction or transient ischemic attacks in hospital or during 6 months of follow-up. There were only 2 reports of ISR in the vertebral artery ostium in the 6 months following DCB-assisted angioplasty. The median modified Rankin scale score was 0. <b>Conclusion:</b> DCB-assisted angioplasty may be feasible for treatment of ISR after stenting of the vertebral artery ostium. However, more research is needed to confirm our findings.</p>","PeriodicalId":94265,"journal":{"name":"Vascular and endovascular surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular and endovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15385744241292115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: Stenting appears to be a safe treatment for vertebral artery ostial stenosis (VAOS) with low complication rates and positive long-term effects. However, in-stent restenosis (ISR) after stenting is common. Drug-coated balloons (DCBs) are an effective management strategy for ISR in patients with coronary or carotid disease. In this study, we investigated the feasibility, safety, and effectiveness of DCB-assisted angioplasty for the treatment of ISR after treatment of VAOS. Research Design: The study included patients in the Department of Neurology at Beijing Tsinghua Changgung Hospital who underwent DCB-assisted angioplasty for ISR after previously undergoing stenting for VAOS. We retrospectively analyzed the clinical and functional outcomes in these patients. Results: Fourteen patients were enrolled in the study between January 2018 and April 2022. Five of the patients were female, and the mean age was 69.4 ± 7.5 years. The technical success rate was 100% and the mean operation time was 57.1 ± 29.2 minutes. No perioperative complications were reported. There were no new cases of cerebral infarction or transient ischemic attacks in hospital or during 6 months of follow-up. There were only 2 reports of ISR in the vertebral artery ostium in the 6 months following DCB-assisted angioplasty. The median modified Rankin scale score was 0. Conclusion: DCB-assisted angioplasty may be feasible for treatment of ISR after stenting of the vertebral artery ostium. However, more research is needed to confirm our findings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
药物涂层球囊血管成形术治疗椎动脉支架内再狭窄:单个中心的经验。
背景和目的:支架置入术似乎是治疗椎动脉骨腔狭窄(VAOS)的一种安全疗法,并发症发生率低,长期效果良好。然而,支架术后支架内再狭窄(ISR)的情况很常见。药物涂层球囊(DCB)是冠状动脉或颈动脉疾病患者治疗 ISR 的有效策略。在这项研究中,我们探讨了 DCB 辅助血管成形术治疗 VAOS 治疗后 ISR 的可行性、安全性和有效性。研究设计:研究对象包括北京清华长庚医院神经内科曾因 VAOS 而接受过支架治疗后,因 ISR 而接受 DCB 辅助血管成形术的患者。我们对这些患者的临床和功能结果进行了回顾性分析。结果:14名患者于2018年1月至2022年4月期间加入研究。其中五名患者为女性,平均年龄为(69.4±7.5)岁。技术成功率为100%,平均手术时间为(57.1±29.2)分钟。无围手术期并发症报告。在住院期间或 6 个月的随访期间,没有出现新的脑梗塞或短暂性脑缺血发作病例。在DCB辅助血管成形术后的6个月内,仅有2例椎动脉骨膜发生ISR的报告。结论:DCB辅助血管成形术后的6个月内,只有2例椎动脉骨膜发生ISR:DCB辅助血管成形术可用于治疗椎动脉骨膜支架置入术后的ISR。然而,还需要更多的研究来证实我们的发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Popliteal Vein Entrapment as a Rare Form of Popliteal Entrapment Syndrome. Challenging Conventional Treatment: Retrograde Implantation of a Covered Stent in Superior Mensenteric Artery Occlusion Case. Smaller Hospital Size is Associated With Higher Mortality in Stanford Type A Aortic Dissection. Acute Vascular Complications of VA-ECMO in COVID-19 Patients. Does COVID-19 Affect the Outcome? Gender-Specific Long-Term Results After Elective Open Abdominal Aortic Aneurysm Repair Depending on the Site of Distal Anastomosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1