Classification of EEG evoked in 2D and 3D virtual reality: traditional machine learning versus deep learning.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Biomedical Physics & Engineering Express Pub Date : 2024-11-05 DOI:10.1088/2057-1976/ad89c5
MingLiang Zuo, BingBing Yu, Li Sui
{"title":"Classification of EEG evoked in 2D and 3D virtual reality: traditional machine learning versus deep learning.","authors":"MingLiang Zuo, BingBing Yu, Li Sui","doi":"10.1088/2057-1976/ad89c5","DOIUrl":null,"url":null,"abstract":"<p><p><i>Backgrounds</i>. Virtual reality (VR) simulates real-life events and scenarios and is widely utilized in education, entertainment, and medicine. VR can be presented in two dimensions (2D) or three dimensions (3D), with 3D VR offering a more realistic and immersive experience. Previous research has shown that electroencephalogram (EEG) profiles induced by 3D VR differ from those of 2D VR in various aspects, including brain rhythm power, activation, and functional connectivity. However, studies focused on classifying EEG in 2D and 3D VR contexts remain limited.<i>Methods</i>. A 56-channel EEG was recorded while visual stimuli were presented in 2D and 3D VR. The recorded EEG signals were classified using two machine learning approaches: traditional machine learning and deep learning. In the traditional approach, features such as power spectral density (PSD) and common spatial patterns (CSP) were extracted, and three classifiers-support vector machines (SVM), K-nearest neighbors (KNN), and random forests (RF)-were used. For the deep learning approach, a specialized convolutional neural network, EEGNet, was employed. The classification performance of these methods was then compared.<i>Results</i>. In terms of accuracy, precision, recall, and F1-score, the deep learning method outperformed traditional machine learning approaches. Specifically, the classification accuracy using the EEGNet deep learning model reached up to 97.86%.<i>Conclusions</i>. EEGNet-based deep learning significantly outperforms conventional machine learning methods in classifying EEG signals induced by 2D and 3D VR. Given EEGNet's design for EEG-based brain-computer interfaces (BCI), this superior classification performance suggests that it can enhance the application of 3D VR in BCI systems.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad89c5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Backgrounds. Virtual reality (VR) simulates real-life events and scenarios and is widely utilized in education, entertainment, and medicine. VR can be presented in two dimensions (2D) or three dimensions (3D), with 3D VR offering a more realistic and immersive experience. Previous research has shown that electroencephalogram (EEG) profiles induced by 3D VR differ from those of 2D VR in various aspects, including brain rhythm power, activation, and functional connectivity. However, studies focused on classifying EEG in 2D and 3D VR contexts remain limited.Methods. A 56-channel EEG was recorded while visual stimuli were presented in 2D and 3D VR. The recorded EEG signals were classified using two machine learning approaches: traditional machine learning and deep learning. In the traditional approach, features such as power spectral density (PSD) and common spatial patterns (CSP) were extracted, and three classifiers-support vector machines (SVM), K-nearest neighbors (KNN), and random forests (RF)-were used. For the deep learning approach, a specialized convolutional neural network, EEGNet, was employed. The classification performance of these methods was then compared.Results. In terms of accuracy, precision, recall, and F1-score, the deep learning method outperformed traditional machine learning approaches. Specifically, the classification accuracy using the EEGNet deep learning model reached up to 97.86%.Conclusions. EEGNet-based deep learning significantly outperforms conventional machine learning methods in classifying EEG signals induced by 2D and 3D VR. Given EEGNet's design for EEG-based brain-computer interfaces (BCI), this superior classification performance suggests that it can enhance the application of 3D VR in BCI systems.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
二维和三维虚拟现实中诱发的脑电图分类:传统机器学习与深度学习。
背景:虚拟现实(VR)模拟现实生活中的事件和场景,广泛应用于教育、娱乐和医疗领域。VR 可以以二维或三维(2D 或 3D )的形式呈现,而 3D VR 能带来更逼真、更身临其境的体验。以往的研究发现,3D VR 诱导的脑电图(EEG)与 2D VR 的脑电图(EEG)具有不同的特征,表现在大脑节律的力量、大脑激活和大脑功能连接等多个方面。方法:记录 64 通道脑电图,同时在 2D 和 3D VR 中给予视觉刺激。对这些记录的脑电信号的分类采用了两种机器学习方法:传统方法和深度学习方法。在传统的机器学习分类中,提取了功率谱密度(PSD)和常见空间模式(CSP)的脑电图特征,并使用了支持向量机(SVM)、K-近邻(KNN)和随机森林(RF)三种分类算法。在深度学习分类中使用了专门的卷积神经网络 EEGNet。对这些分类方法的分类性能进行了比较:结果:在分类的准确度、精确度、召回率和 F1 分数这四个性能评估方面,使用深度学习方法进行的分类优于传统的机器学习方法。使用深度学习与 EEGNet 的分类准确率高达 97.86%:结论:基于 EEGNet 的深度学习可以实现二维和三维 VR 诱导脑电图的分类性能,优于传统的机器学习方法。鉴于 EEGNet 专为基于脑电图的脑机接口(BCI)而设计,因此可以预见,在二维和三维 VR 环境中,更好的脑电图分类性能将有助于三维 VR 在 BCI 中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
期刊最新文献
Dose compensation for decreased biological effective dose due to intrafractional interruption during radiotherapy: integration with a commercial treatment planning system. Open-window MSR Design with Active Magnetic Compensation Coil based on COMSOL Multiphysics. A new method to assess the performance of anti-scatter grids in x-ray projection imaging. Effect of tissue viscoelasticity on delivered mechanical power in a physical respiratory system model: distinguishing between airway and tissue resistance. Local field potential-based brain-machine interface to inhibit epileptic seizures by spinal cord electrical stimulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1