How do intraocular lens materials influence the outcome of cataract surgery?

IF 3 2区 医学 Q1 OPHTHALMOLOGY Current Opinion in Ophthalmology Pub Date : 2024-10-17 DOI:10.1097/ICU.0000000000001095
Andrzej Grzybowski, Gerd U Auffarth, Benjamin R LaHood
{"title":"How do intraocular lens materials influence the outcome of cataract surgery?","authors":"Andrzej Grzybowski, Gerd U Auffarth, Benjamin R LaHood","doi":"10.1097/ICU.0000000000001095","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>This review summarizes the evidence on the effect of intraocular lens (IOL) material on the outcomes of cataract surgery, as well as on the surgical procedure itself.</p><p><strong>Recent findings: </strong>Differences in capsular biocompatibility between IOL materials lead to variations in capsular stability and posterior capsule opacification (PCO), while differences in uveal biocompatibility affect postoperative inflammatory response.</p><p><strong>Summary: </strong>Refractive outcomes are affected by both incision size and the rotational stability of toric IOLs. Small incision sizes favour hydrophilic IOLs. Rotational stability of hydrophobic and hydrophilic IOLs were comparable in recent studies. Visual outcomes are affected by chromatic aberrations, dysphotopsia, lens opacifications and PCO. Hydrophilic IOLs are associated with reduced chromatic dispersion. Hydrophobic IOL opacifications are caused by sub-surface glistenings, while hydrophilic IOL opacifications are due to surface calcifications. Some surgeries, including pars plana vitrectomy and lamellar corneal transplants, were shown to increase the risk of IOL calcifications, although the mechanism is still unknown. Hydrophilic IOLs have greater ease of manipulation, greater resistance to IOL damage, and higher uveal biocompatibility. Hydrophobic IOLs show better PCO prevention than hydrophilic IOLs, and should be preferred in highly myopic eyes where Nd:YAG capsulotomy might increase the risk of retinal detachment.</p>","PeriodicalId":50604,"journal":{"name":"Current Opinion in Ophthalmology","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICU.0000000000001095","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose of review: This review summarizes the evidence on the effect of intraocular lens (IOL) material on the outcomes of cataract surgery, as well as on the surgical procedure itself.

Recent findings: Differences in capsular biocompatibility between IOL materials lead to variations in capsular stability and posterior capsule opacification (PCO), while differences in uveal biocompatibility affect postoperative inflammatory response.

Summary: Refractive outcomes are affected by both incision size and the rotational stability of toric IOLs. Small incision sizes favour hydrophilic IOLs. Rotational stability of hydrophobic and hydrophilic IOLs were comparable in recent studies. Visual outcomes are affected by chromatic aberrations, dysphotopsia, lens opacifications and PCO. Hydrophilic IOLs are associated with reduced chromatic dispersion. Hydrophobic IOL opacifications are caused by sub-surface glistenings, while hydrophilic IOL opacifications are due to surface calcifications. Some surgeries, including pars plana vitrectomy and lamellar corneal transplants, were shown to increase the risk of IOL calcifications, although the mechanism is still unknown. Hydrophilic IOLs have greater ease of manipulation, greater resistance to IOL damage, and higher uveal biocompatibility. Hydrophobic IOLs show better PCO prevention than hydrophilic IOLs, and should be preferred in highly myopic eyes where Nd:YAG capsulotomy might increase the risk of retinal detachment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
眼内晶体材料如何影响白内障手术的效果?
综述目的:本综述总结了眼内人工晶体(IOL)材料对白内障手术效果以及手术过程本身影响的证据:不同人工晶体材料的囊内生物相容性差异会导致囊稳定性和后囊不透明(PCO)的变化,而葡萄膜生物相容性的差异会影响术后炎症反应:摘要:屈光结果受切口大小和散光人工晶体旋转稳定性的影响。小切口有利于亲水性人工晶体。在最近的研究中,疏水性和亲水性人工晶体的旋转稳定性相当。视觉效果受色差、视力障碍、晶状体混浊和 PCO 的影响。亲水性人工晶体可减少色散。疏水性人工晶体不透明是由表面下的晶状体造成的,而亲水性人工晶体不透明则是由表面钙化造成的。一些手术,包括玻璃体旁切除术和板层角膜移植术,被证明会增加人工晶体钙化的风险,但其机理尚不清楚。亲水性人工晶体更易于操作,更耐人工晶体损伤,具有更高的葡萄膜生物相容性。疏水性人工晶体比亲水性人工晶体能更好地预防 PCO,对于 Nd:YAG 包囊切开术可能会增加视网膜脱离风险的高度近视眼,疏水性人工晶体是首选。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.80
自引率
5.40%
发文量
120
审稿时长
6-12 weeks
期刊介绍: Current Opinion in Ophthalmology is an indispensable resource featuring key up-to-date and important advances in the field from around the world. With renowned guest editors for each section, every bimonthly issue of Current Opinion in Ophthalmology delivers a fresh insight into topics such as glaucoma, refractive surgery and corneal and external disorders. With ten sections in total, the journal provides a convenient and thorough review of the field and will be of interest to researchers, clinicians and other healthcare professionals alike.
期刊最新文献
The effect of cataract surgery on lowering intraocular pressure. Artificial intelligence in ophthalmology. A comprehensive update on over the counter artificial tears. Challenges and outcomes of cataract surgery after vitrectomy. Cataract surgery combined with glaucoma surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1