Leonardo Mohamad Nassani, Samuel Storts, Irina Novopoltseva, Lauren Ann Place, Matthew Fogarty, Pete Schupska
{"title":"Impact Absorption Power of Polyolefin Fused Filament Fabrication 3D-Printed Sports Mouthguards: In Vitro Study.","authors":"Leonardo Mohamad Nassani, Samuel Storts, Irina Novopoltseva, Lauren Ann Place, Matthew Fogarty, Pete Schupska","doi":"10.1111/edt.13001","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aim: </strong>This study aims to evaluate and compare the impact absorption capacities of thermoformed ethylene vinyl acetate (EVA) mouthguards and 3D-printed polyolefin mouthguards used in sports dentistry applications. The objective is to determine whether 3D-printed polyolefin mouthguards offer superior impact toughness compared to traditional EVA mouthguards commonly used in sports settings.</p><p><strong>Materials and methods: </strong>Six material samples were assessed: five pressure-formed EVA mouthguards (PolyShok, Buffalo Dental, Erkoflex, Proform, and Drufosoft) and one 3D-printed synthetic polymer (polyolefin). The materials were evaluated using a modified American Society for Testing and Materials (ASTM) D256 Test Method A for Izod pendulum impact resistance of plastics. Polyolefin samples were 3D-printed using fused filament fabrication (FFF) technology. Notably, the FFF process included samples printed with notches placed either parallel or perpendicular to the build direction. This orientation served as a study factor, allowing for comparison of material behavior under different printing conditions. Impact testing was conducted using an Izod impact tester to assess the materials' performance under controlled impact conditions.</p><p><strong>Results: </strong>The study achieved a high power (1.0) in power analysis, indicating strong sensitivity to detect significant differences. Among molded materials, PolyShok showed significantly lower impact toughness compared to others (p = 0.06). The mean impact absorption of EVA materials was 5.4 ± 0.3 kJ/m<sup>2</sup>, significantly lower than polyolefin materials, which demonstrated 12.9 ± 0.7 kJ/m<sup>2</sup> and superior performance (p = 0.0). Horizontal-notched polyolefin samples exhibited higher impact strength compared to vertical-notched samples (p = 0.009).</p><p><strong>Conclusions: </strong>3D-printed polyolefin mouthguards exhibited significantly higher impact toughness than thermoformed EVA mouthguards. While EVA materials demonstrated structural robustness, their lower impact resistance and observed tearing in other test specimens suggest the need for alternative testing standards to better reflect real-world conditions. 3D-printed mouthguards fabricated with build orientations perpendicular to the direction of impact demonstrate significantly enhanced impact absorption. Further research into manufacturing methods and testing protocols is recommended to optimize mouthguard performance under impact scenarios.</p>","PeriodicalId":55180,"journal":{"name":"Dental Traumatology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/edt.13001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background/aim: This study aims to evaluate and compare the impact absorption capacities of thermoformed ethylene vinyl acetate (EVA) mouthguards and 3D-printed polyolefin mouthguards used in sports dentistry applications. The objective is to determine whether 3D-printed polyolefin mouthguards offer superior impact toughness compared to traditional EVA mouthguards commonly used in sports settings.
Materials and methods: Six material samples were assessed: five pressure-formed EVA mouthguards (PolyShok, Buffalo Dental, Erkoflex, Proform, and Drufosoft) and one 3D-printed synthetic polymer (polyolefin). The materials were evaluated using a modified American Society for Testing and Materials (ASTM) D256 Test Method A for Izod pendulum impact resistance of plastics. Polyolefin samples were 3D-printed using fused filament fabrication (FFF) technology. Notably, the FFF process included samples printed with notches placed either parallel or perpendicular to the build direction. This orientation served as a study factor, allowing for comparison of material behavior under different printing conditions. Impact testing was conducted using an Izod impact tester to assess the materials' performance under controlled impact conditions.
Results: The study achieved a high power (1.0) in power analysis, indicating strong sensitivity to detect significant differences. Among molded materials, PolyShok showed significantly lower impact toughness compared to others (p = 0.06). The mean impact absorption of EVA materials was 5.4 ± 0.3 kJ/m2, significantly lower than polyolefin materials, which demonstrated 12.9 ± 0.7 kJ/m2 and superior performance (p = 0.0). Horizontal-notched polyolefin samples exhibited higher impact strength compared to vertical-notched samples (p = 0.009).
Conclusions: 3D-printed polyolefin mouthguards exhibited significantly higher impact toughness than thermoformed EVA mouthguards. While EVA materials demonstrated structural robustness, their lower impact resistance and observed tearing in other test specimens suggest the need for alternative testing standards to better reflect real-world conditions. 3D-printed mouthguards fabricated with build orientations perpendicular to the direction of impact demonstrate significantly enhanced impact absorption. Further research into manufacturing methods and testing protocols is recommended to optimize mouthguard performance under impact scenarios.
期刊介绍:
Dental Traumatology is an international journal that aims to convey scientific and clinical progress in all areas related to adult and pediatric dental traumatology. This includes the following topics:
- Epidemiology, Social Aspects, Education, Diagnostics
- Esthetics / Prosthetics/ Restorative
- Evidence Based Traumatology & Study Design
- Oral & Maxillofacial Surgery/Transplant/Implant
- Pediatrics and Orthodontics
- Prevention and Sports Dentistry
- Endodontics and Periodontal Aspects
The journal"s aim is to promote communication among clinicians, educators, researchers, and others interested in the field of dental traumatology.