{"title":"A Study of Thermal Cycle Circuits of NPPs Combined with Fossil Fueled Power Installations","authors":"V. O. Kindra,&nbsp;I. A. Maksimov,&nbsp;D. V. Patorkin,&nbsp;I. I. Komarov,&nbsp;O. V. Zlyvko","doi":"10.1134/S0040601524700344","DOIUrl":null,"url":null,"abstract":"<p>The need to adapt the world’s industry and economy to constantly tightening climatic standards, as well as a constant growth of energy consumption, facilitate the development of carbon-free electricity generation technologies. Renewable energy and nuclear power plants are referred to energy sources having almost zero carbon dioxide emissions into the atmosphere. However, in view of an insufficient amount of renewable energy resources near large electricity consumers, NPPs play the most important role in the potential transition to the carbon-free economy of Russia. However, they do have certain drawbacks, such as comparatively low energy efficiency, poor maneuverability, and also high specific capital outlays. Combined use of nuclear and fossil fuel may become one of ways for partially removing these drawbacks. The article addresses a thermodynamic analysis of using fossil fuel at an NPP in an external steam superheater with subsequently expanding a part of the steam in a high-temperature turbine. A process circuit solution is proposed whose use makes it possible to obtain an expanded power unit load adjustment range. It has been shown from thermodynamic analysis results that, by subjecting a certain amount of steam from the steam generator to external superheating, it becomes possible to increase the nuclear power unit’s power output and efficiency: the maximal increase in the electric power output can total 338, 382, and 426 MW and that of net electrical efficiency of 0.73, 1.08, and 1.43% at steam superheating temperatures equal to 560, 600, and 640°С, respectively. The hybrid unit employing nuclear and hydrocarbon fuel that operates according to the proposed process cycle circuit includes a smaller amount of main equipment and features wider load adjustment ranges in comparison with standalone NPP and steam turbine thermal power plant: 102.3–132.7, 103.0–136.9, and 103.6–141.2% with respect to the reference process cycle circuit at steam superheating temperatures equal to 560, 600, and 640°С, respectively.</p>","PeriodicalId":799,"journal":{"name":"Thermal Engineering","volume":"71 10","pages":"840 - 851"},"PeriodicalIF":0.9000,"publicationDate":"2024-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1134/S0040601524700344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

The need to adapt the world’s industry and economy to constantly tightening climatic standards, as well as a constant growth of energy consumption, facilitate the development of carbon-free electricity generation technologies. Renewable energy and nuclear power plants are referred to energy sources having almost zero carbon dioxide emissions into the atmosphere. However, in view of an insufficient amount of renewable energy resources near large electricity consumers, NPPs play the most important role in the potential transition to the carbon-free economy of Russia. However, they do have certain drawbacks, such as comparatively low energy efficiency, poor maneuverability, and also high specific capital outlays. Combined use of nuclear and fossil fuel may become one of ways for partially removing these drawbacks. The article addresses a thermodynamic analysis of using fossil fuel at an NPP in an external steam superheater with subsequently expanding a part of the steam in a high-temperature turbine. A process circuit solution is proposed whose use makes it possible to obtain an expanded power unit load adjustment range. It has been shown from thermodynamic analysis results that, by subjecting a certain amount of steam from the steam generator to external superheating, it becomes possible to increase the nuclear power unit’s power output and efficiency: the maximal increase in the electric power output can total 338, 382, and 426 MW and that of net electrical efficiency of 0.73, 1.08, and 1.43% at steam superheating temperatures equal to 560, 600, and 640°С, respectively. The hybrid unit employing nuclear and hydrocarbon fuel that operates according to the proposed process cycle circuit includes a smaller amount of main equipment and features wider load adjustment ranges in comparison with standalone NPP and steam turbine thermal power plant: 102.3–132.7, 103.0–136.9, and 103.6–141.2% with respect to the reference process cycle circuit at steam superheating temperatures equal to 560, 600, and 640°С, respectively.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
核电站与化石燃料发电装置相结合的热循环回路研究
为使世界工业和经济适应不断收紧的气候标准,以及能源消耗的持续增长,促进了无碳发电技术的发展。可再生能源和核电站指的是向大气中几乎零排放二氧化碳的能源。然而,鉴于用电大户附近的可再生能源资源不足,核电站在俄罗斯向无碳经济过渡的潜在过程中发挥着最重要的作用。然而,它们也有一些缺点,如能效相对较低、可操作性差,以及具体资本支出较高。核燃料和化石燃料的联合使用可能是部分消除这些缺点的方法之一。文章对核电厂在外部蒸汽过热器中使用化石燃料,并随后在高温涡轮机中膨胀部分蒸汽进行了热力学分析。文章提出了一种工艺回路解决方案,使用该方案可以扩大功率单位负荷调节范围。热力学分析结果表明,通过对蒸汽发生器中的一定量蒸汽进行外部过热,可以提高核电机组的功率输出和效率:在蒸汽过热温度分别为 560、600 和 640°С时,电力输出的最大增幅分别为 338、382 和 426 兆瓦,净电力效率分别为 0.73、1.08 和 1.43%。与独立的核电厂和蒸汽轮机热电厂相比,根据拟议的工艺循环回路运行的采用核燃料和碳氢化合物燃料的混合机组的主要设备数量较少,负荷调节范围较宽:与参考工艺循环回路相比,在蒸汽过热温度等于 560、600 和 640°С 时,负荷调节范围分别为 102.3-132.7、103.0-136.9 和 103.6-141.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
20.00%
发文量
94
期刊最新文献
Erratum to: Directions for Increasing Thermal Efficiency of an NPP with PWR Analyzing the State of Phosphate Water Chemistries in High-Pressure Drum Boilers Results of Application of Ammonia-Ethanolamine Water Chemistry in the Secondary Circuit of Power Units with a VVER-1200 Reactor Mechanisms of Metal Degradation in Equipment and Pipelines of Turbo Plants of Nuclear Power Plant Units: Classification and Identification Approximation Formula for Calculating the Heat Capacity of Liquid Lead from the Melting Point to the Boiling Point
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1