High time resolution quantification of PM2.5 oxidative potential at a Central London roadside supersite

IF 10.3 1区 环境科学与生态学 Q1 ENVIRONMENTAL SCIENCES Environment International Pub Date : 2024-11-01 DOI:10.1016/j.envint.2024.109102
Steven J. Campbell , Alexandre Barth , Gang I. Chen , Anja H. Tremper , Max Priestman , David Ek , Shuming Gu , Frank J. Kelly , Markus Kalberer , David C. Green
{"title":"High time resolution quantification of PM2.5 oxidative potential at a Central London roadside supersite","authors":"Steven J. Campbell ,&nbsp;Alexandre Barth ,&nbsp;Gang I. Chen ,&nbsp;Anja H. Tremper ,&nbsp;Max Priestman ,&nbsp;David Ek ,&nbsp;Shuming Gu ,&nbsp;Frank J. Kelly ,&nbsp;Markus Kalberer ,&nbsp;David C. Green","doi":"10.1016/j.envint.2024.109102","DOIUrl":null,"url":null,"abstract":"<div><div>The oxidative potential (OP) of airborne particulate matter (PM) is gaining increasing attention as a health-relevant metric to describe the capacity of PM to promote oxidative stress and cause adverse health effects. To date, most OP studies use filter-based approaches to sample PM and quantify OP, which have relatively poor time resolution (∼24 h) and underestimate the contribution of reactive components to OP due to the time delay between sample collection and analysis. To address this important limitation, we have developed a novel instrument which uses a direct-to-reagent sampling approach, providing robust, continuous, high time resolution (5 min) OP quantification, hence overcoming analytical limitations of filter-based techniques. In this study, we deployed this instrument in the Marylebone Road Air Quality Monitoring Station in London, UK, alongside a broad suite of high time resolution PM<sub>2.5</sub> composition measurements for three months continuous measurement during Summer 2023. High time resolution OP quantification reveals dynamic changes in volume-normalised (OP<sub>v</sub>) and mass normalised (OP<sub>m</sub>) OP evolving over ∼hourly timescales, observed at an average PM<sub>2.5</sub> mass concentration of 7.1 ± 4.2 µg m<sup>−3</sup>, below the WHO interim 4 target of 10 µg m<sup>−3</sup>. In addition, high time resolution data facilitates directional analysis, allowing us to determine the influence of wind speed and wind direction on OP, and the identification of PM<sub>2.5</sub> chemical components and sources which drive dynamic changes in OP; this includes traffic emissions, as well as emissions from the London Underground into the ambient airshed. These results demonstrate the capacity of high time resolution measurements to provide new insights into the temporal evolution of OP, as well as the composition and emission sources which drive OP, developing our understanding of the characteristics of PM<sub>2.5</sub> which may promote adverse health impacts.</div></div>","PeriodicalId":308,"journal":{"name":"Environment International","volume":"193 ","pages":"Article 109102"},"PeriodicalIF":10.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environment International","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0160412024006883","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The oxidative potential (OP) of airborne particulate matter (PM) is gaining increasing attention as a health-relevant metric to describe the capacity of PM to promote oxidative stress and cause adverse health effects. To date, most OP studies use filter-based approaches to sample PM and quantify OP, which have relatively poor time resolution (∼24 h) and underestimate the contribution of reactive components to OP due to the time delay between sample collection and analysis. To address this important limitation, we have developed a novel instrument which uses a direct-to-reagent sampling approach, providing robust, continuous, high time resolution (5 min) OP quantification, hence overcoming analytical limitations of filter-based techniques. In this study, we deployed this instrument in the Marylebone Road Air Quality Monitoring Station in London, UK, alongside a broad suite of high time resolution PM2.5 composition measurements for three months continuous measurement during Summer 2023. High time resolution OP quantification reveals dynamic changes in volume-normalised (OPv) and mass normalised (OPm) OP evolving over ∼hourly timescales, observed at an average PM2.5 mass concentration of 7.1 ± 4.2 µg m−3, below the WHO interim 4 target of 10 µg m−3. In addition, high time resolution data facilitates directional analysis, allowing us to determine the influence of wind speed and wind direction on OP, and the identification of PM2.5 chemical components and sources which drive dynamic changes in OP; this includes traffic emissions, as well as emissions from the London Underground into the ambient airshed. These results demonstrate the capacity of high time resolution measurements to provide new insights into the temporal evolution of OP, as well as the composition and emission sources which drive OP, developing our understanding of the characteristics of PM2.5 which may promote adverse health impacts.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
伦敦市中心路边超级站点 PM2.5 氧化潜能的高时间分辨率量化
空气中颗粒物(PM)的氧化潜能(OP)作为一种与健康相关的指标,越来越受到人们的关注,因为它可以描述PM促进氧化应激和造成不良健康影响的能力。迄今为止,大多数 OP 研究都采用基于过滤器的方法对 PM 进行采样并量化 OP,这种方法的时间分辨率相对较低(∼ 24 小时),并且由于样品采集和分析之间的时间延迟,会低估活性成分对 OP 的贡献。为了解决这一重要的局限性,我们开发了一种新型仪器,它采用直接对试剂采样的方法,提供稳健、连续、高时间分辨率(5 分钟)的 OP 定量,从而克服了基于过滤器技术的分析局限性。在这项研究中,我们在英国伦敦玛丽伯恩路空气质量监测站部署了这一仪器,并在 2023 年夏季进行了为期三个月的连续测量,同时还进行了广泛的高时间分辨率 PM2.5 成分测量。高时间分辨率 OP 定量揭示了体积归一化(OPv)和质量归一化(OPm)OP 在每小时时间尺度上的动态变化,观测到的 PM2.5 平均质量浓度为 7.1 ± 4.2 µg m-3,低于世界卫生组织中期目标 4 10 µg m-3。此外,高时间分辨率数据有助于进行方向分析,使我们能够确定风速和风向对 OP 的影响,并确定 PM2.5 的化学成分以及推动 OP 动态变化的来源;这包括交通排放以及从伦敦地铁排放到环境空气流通中的气体。这些结果表明,高时间分辨率测量能够提供有关 OP 的时间演变以及驱动 OP 的成分和排放源的新见解,从而加深我们对可能对健康产生不利影响的 PM2.5 特征的理解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Environment International
Environment International 环境科学-环境科学
CiteScore
21.90
自引率
3.40%
发文量
734
审稿时长
2.8 months
期刊介绍: Environmental Health publishes manuscripts focusing on critical aspects of environmental and occupational medicine, including studies in toxicology and epidemiology, to illuminate the human health implications of exposure to environmental hazards. The journal adopts an open-access model and practices open peer review. It caters to scientists and practitioners across all environmental science domains, directly or indirectly impacting human health and well-being. With a commitment to enhancing the prevention of environmentally-related health risks, Environmental Health serves as a public health journal for the community and scientists engaged in matters of public health significance concerning the environment.
期刊最新文献
Analysis of the stereoselective fate and toxicity of penflufen in the water-sediment system for risk reduction Uncovering global risk to human and ecosystem health from pesticides in agricultural surface water using a machine learning approach Low dose exposure to dioxins alters hepatic energy metabolism and steatotic liver disease development in a sex-specific manner Seasonal dynamics of the phage-bacterium linkage and associated antibiotic resistome in airborne PM2.5 of urban areas Assessment of risk for aromatic hydrocarbons resulting from subsea Blowouts: A case study in eastern Canada
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1