Yann Philippe Charles, François Severac, Susana Núñez-Pereira, Sleiman Haddad, Lluis Vila, Ferran Pellisé, Ibrahim Obeid, Louis Boissière, Caglar Yilgor, Altug Yucekul, Ahmet Alanay, Frank Kleinstück, Markus Loibl, Alejandro Gómez-Rice, Riccardo Raganato, Francisco Javier Sánchez Perez-Grueso, Javier Pizones
{"title":"Influence of implant density on mechanical complications in adult spinal deformity surgery.","authors":"Yann Philippe Charles, François Severac, Susana Núñez-Pereira, Sleiman Haddad, Lluis Vila, Ferran Pellisé, Ibrahim Obeid, Louis Boissière, Caglar Yilgor, Altug Yucekul, Ahmet Alanay, Frank Kleinstück, Markus Loibl, Alejandro Gómez-Rice, Riccardo Raganato, Francisco Javier Sánchez Perez-Grueso, Javier Pizones","doi":"10.1007/s00586-024-08543-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose was to analyze how rod characteristics, screw density and cages influence the incidence of mechanical complications compared to patient-related factors and alignment in adult spinal deformity instrumented T9-T11 to pelvis.</p><p><strong>Methods: </strong>Register data of 302 patients was analyzed. Relative lumbar lordosis (RLL) and relative sagittal alignment (RSA) was measured. Surgical data included rod characteristics, pedicle screw density and interbody cages. Univariate and multivariate logistic regression models were used.</p><p><strong>Results: </strong>Pseudarthrosis occurred in 24.1%. On univariate analysis Odds Ratio (OR) was 0.74 for ≥ 3 cages (p = 0.452), 0.48 for 4 rods (p = 0.008), 4.30 for high screw density (p = 0.001). Patient-related factors were non-significant. Multivariate OR was 0.59 for 4 rods (p = 0.084) and 4.67 for high screw density (p = 0.005). PJK/PJF occurred in 19.2%. Age > 60 had an OR 2.83 (p = 0.023), postoperative RSA malaligned OR 2.84 (p = 0.030), severely malaligned OR 6.54 (p < 0.001). Implant characteristics were non-significant. Multivariate OR was 1.26 for age > 60 (p = 0.657), 2.32 for malaligned RSA (p = 0.097), 5.69 for severely malaligned RSA (p = 0.001). Screw loosening occurred in 8.9%. Univariate OR was 0.95 for ≥ 3 cages (p = 0.920), 1.64 for 4 rods (p = 0.235), 0.25 for high screw density 1.5-2 (p = 0.011). Patient-related factors were non-significant. Multivariate OR for high screw density was 0.23 (p = 0.022).</p><p><strong>Conclusion: </strong>Four rods decrease the pseudarthrosis risk. Cages have a secondary role. High screw density doesn't prevent from pseudarthrosis. Postoperative malalignment is the main PJK/PJF risk factor. Age plays a secondary role. Implant characteristics have a minor influence. High screw density constructs have a lower risk for screw loosening.</p><p><strong>Level of evidence: </strong>3-Retrospective register study.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":" ","pages":"4643-4652"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08543-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The purpose was to analyze how rod characteristics, screw density and cages influence the incidence of mechanical complications compared to patient-related factors and alignment in adult spinal deformity instrumented T9-T11 to pelvis.
Methods: Register data of 302 patients was analyzed. Relative lumbar lordosis (RLL) and relative sagittal alignment (RSA) was measured. Surgical data included rod characteristics, pedicle screw density and interbody cages. Univariate and multivariate logistic regression models were used.
Results: Pseudarthrosis occurred in 24.1%. On univariate analysis Odds Ratio (OR) was 0.74 for ≥ 3 cages (p = 0.452), 0.48 for 4 rods (p = 0.008), 4.30 for high screw density (p = 0.001). Patient-related factors were non-significant. Multivariate OR was 0.59 for 4 rods (p = 0.084) and 4.67 for high screw density (p = 0.005). PJK/PJF occurred in 19.2%. Age > 60 had an OR 2.83 (p = 0.023), postoperative RSA malaligned OR 2.84 (p = 0.030), severely malaligned OR 6.54 (p < 0.001). Implant characteristics were non-significant. Multivariate OR was 1.26 for age > 60 (p = 0.657), 2.32 for malaligned RSA (p = 0.097), 5.69 for severely malaligned RSA (p = 0.001). Screw loosening occurred in 8.9%. Univariate OR was 0.95 for ≥ 3 cages (p = 0.920), 1.64 for 4 rods (p = 0.235), 0.25 for high screw density 1.5-2 (p = 0.011). Patient-related factors were non-significant. Multivariate OR for high screw density was 0.23 (p = 0.022).
Conclusion: Four rods decrease the pseudarthrosis risk. Cages have a secondary role. High screw density doesn't prevent from pseudarthrosis. Postoperative malalignment is the main PJK/PJF risk factor. Age plays a secondary role. Implant characteristics have a minor influence. High screw density constructs have a lower risk for screw loosening.
Level of evidence: 3-Retrospective register study.
期刊介绍:
"European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts.