Color Stability of PMMA Resins for Complete Denture Produced by CAD/CAM and 3D Printing Technologies: An In Vitro Study.

Martina Bonvicini, Carlo Monaco, Antonio Arena, Ugo Consolo, Davide Silvestri, Francesca Zicari
{"title":"Color Stability of PMMA Resins for Complete Denture Produced by CAD/CAM and 3D Printing Technologies: An In Vitro Study.","authors":"Martina Bonvicini, Carlo Monaco, Antonio Arena, Ugo Consolo, Davide Silvestri, Francesca Zicari","doi":"10.11607/ijp.9191","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the effect of a staining solution on color stability of resins for complete dentures produced with conventional and digital technologies.</p><p><strong>Materials and methods: </strong>60 resin specimens were prepared and divided in 6 groups of 10 specimens each: Probase Hot (PH, Ivoclar AG), IvoBase CAD (IBC, Ivoclar AG), Ivotion Dent (ID, Ivoclar AG), Ivotion Dent Multi (IDM, Ivoclar AG), Dima Print Denture Base (DPDB, Kulzer), and Dima Print Denture Teeth (DPDT, Kulzer). One surface of each specimen was polished following the manufacturer's instructions. The CIELab color differences were evaluated before and after immersion for 28 days in a coffee solution and measured as DE using two dental spectrophotometers. One specimen for each group was selected for SEM analysis at baseline and at 28-day.</p><p><strong>Results: </strong>Data analysis was performed by Kruskal-Wallis test and post-hoc Dunn test for comparison. Regarding specimens analyzed with VITA Easyshade, IDM white zone (polished and unpolished) scored higher (∆E= 0.87 and ∆E = 1.15 respectively). All milled samples (IBC, ID, IDM pink zone), scored significantly higher as compared to PH and DPDT. Regarding Spectroshade, IDM pink zone performed better, regarding both polished and unpolished specimens (∆E=1.57 and ∆E=2.07 respectively). ID demonstrated a statistic higher color stability compared to PH and DPDT. Regarding the SEM analysis any differences in surface morphology was observed between baseline and 28-days immersion analyses.</p><p><strong>Conclusions: </strong>Color stability is significantly higher in resin specimens obtained with digital technologies as compared to conventional resin specimens after immersion in a staining solution.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-24"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this in vitro study was to evaluate the effect of a staining solution on color stability of resins for complete dentures produced with conventional and digital technologies.

Materials and methods: 60 resin specimens were prepared and divided in 6 groups of 10 specimens each: Probase Hot (PH, Ivoclar AG), IvoBase CAD (IBC, Ivoclar AG), Ivotion Dent (ID, Ivoclar AG), Ivotion Dent Multi (IDM, Ivoclar AG), Dima Print Denture Base (DPDB, Kulzer), and Dima Print Denture Teeth (DPDT, Kulzer). One surface of each specimen was polished following the manufacturer's instructions. The CIELab color differences were evaluated before and after immersion for 28 days in a coffee solution and measured as DE using two dental spectrophotometers. One specimen for each group was selected for SEM analysis at baseline and at 28-day.

Results: Data analysis was performed by Kruskal-Wallis test and post-hoc Dunn test for comparison. Regarding specimens analyzed with VITA Easyshade, IDM white zone (polished and unpolished) scored higher (∆E= 0.87 and ∆E = 1.15 respectively). All milled samples (IBC, ID, IDM pink zone), scored significantly higher as compared to PH and DPDT. Regarding Spectroshade, IDM pink zone performed better, regarding both polished and unpolished specimens (∆E=1.57 and ∆E=2.07 respectively). ID demonstrated a statistic higher color stability compared to PH and DPDT. Regarding the SEM analysis any differences in surface morphology was observed between baseline and 28-days immersion analyses.

Conclusions: Color stability is significantly higher in resin specimens obtained with digital technologies as compared to conventional resin specimens after immersion in a staining solution.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用 CAD/CAM 和 3D 打印技术制作的全口义齿 PMMA 树脂的颜色稳定性:体外研究
目的:本体外研究的目的是评估染色溶液对使用传统和数字技术制作的全口义齿树脂颜色稳定性的影响:Probase Hot (PH, Ivoclar AG)、IvoBase CAD (IBC, Ivoclar AG)、Ivotion Dent (ID, Ivoclar AG)、Ivotion Dent Multi (IDM, Ivoclar AG)、Dima Print Denture Base (DPDB, Kulzer)和Dima Print Denture Teeth (DPDT, Kulzer)。按照制造商的说明对每个试样的一个表面进行抛光。在咖啡溶液中浸泡 28 天前后对 CIELab 色差进行评估,并使用两台牙科分光光度计测量 DE 值。每组选取一个标本进行基线和 28 天的扫描电镜分析:数据分析采用 Kruskal-Wallis 检验和事后 Dunn 检验进行比较。用 VITA Easyshade 分析的试样中,IDM 白区(抛光和未抛光)得分较高(∆E= 0.87 和 ∆E= 1.15)。与 PH 和 DPDT 相比,所有研磨样品(IBC、ID、IDM 粉色区)的得分都明显更高。在分光光度方面,IDM 粉红区在抛光和未抛光样品中的表现都更好(∆E=1.57 和 ∆E=2.07)。与 PH 和 DPDT 相比,ID 的颜色稳定性更高。在 SEM 分析中,基线分析和 28 天浸泡分析的表面形态没有任何差异:结论:与传统树脂试样相比,使用数字技术获得的树脂试样在染色溶液中浸泡后的颜色稳定性明显更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maxillary All-on-6 Treatment Using Zygomatic Implants. Bone Loss Evaluation by CBCT: 3-Year Follow-up. The 'One Customized Abutment One Time' Concept-An Innovative Technique for Optimizing Immediacy and Digital Protocols. Conversion of the Anatomical Crown of a Natural Tooth to an Interim Implant-Retained Restoration for Enhanced Esthetics and Soft Tissue Stability in the Esthetic Zone: A Clinical Report. Long-Term Peri-implant Health and Papilla Formation at Healed Sites with Chairside Provisionalization of Single-Tooth Implants: A Prospective Case Series. Composite Restoration Design Effect During Curing and Chewing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1