{"title":"Siphon-based scalable and salt-resistant multistage thermal desalination system","authors":"Nabajit Deka, Meeran Mehmood Qari, Susmita Dash","doi":"10.1016/j.desal.2024.118200","DOIUrl":null,"url":null,"abstract":"<div><div>Recent advances in thermal localization-based passive solar desalination provide a great opportunity for the economical generation of freshwater, particularly in regions with insufficient energy and water infrastructure. Yet, the capillary-assisted passive desalination systems with a high-water productivity flux (measured in Lm<sup>−2</sup> h<sup>−1</sup>) suffer from the issue of performance degradation due to salt accumulation and the inability to be scaled up. In this work, we propose siphon-based supply of saline water over the evaporator that enables scale up of the desalination system to a size significantly higher than the capillary rise height of the hydrophilic evaporator while preventing salt accumulation on the evaporator. The composite siphon comprises insulating fabric wick and a metallic grooved surface for localizing heat to evaporate a thin layer of saline liquid over the evaporator. We perform heat and mass transfer analysis to show that the thermal-to-vapor efficiency depends on the inlet mass flow rate and air gap between the evaporator and the condenser. We propose a methodology to passively control the mass flow rate to maximize the thermal to vapor efficiency at different input heat flux and initial concentration of the brine. A grooved condenser avoids mixing of brine and the freshwater, even at air gaps as low as 2 mm. A siphon-assisted 10-stage desalination system with a footprint area 15 cm <span><math><mo>×</mo></math></span> 15 cm and an air gap of 2 mm is shown to have a high water productivity flux of <span><math><mo>∼</mo></math></span>5.73 Lm<sup>−2</sup> h<sup>−1</sup> from 3.5 wt% saline water at an applied heat flux 1000 W/m<sup>2</sup>, which increases to a record high distillate flux of ∼6.23 Lm<sup>−2</sup> h<sup>−1</sup> and thermal to water collection efficiency of ∼423 % for a 15-stage system. The ability of the desalination system to maintain a high-water productivity flux even when the evaporator area is increased by 4 times demonstrates its scalability to achieve higher desalinated water productivity rate.</div></div>","PeriodicalId":299,"journal":{"name":"Desalination","volume":"593 ","pages":"Article 118200"},"PeriodicalIF":8.3000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Desalination","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0011916424009111","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Recent advances in thermal localization-based passive solar desalination provide a great opportunity for the economical generation of freshwater, particularly in regions with insufficient energy and water infrastructure. Yet, the capillary-assisted passive desalination systems with a high-water productivity flux (measured in Lm−2 h−1) suffer from the issue of performance degradation due to salt accumulation and the inability to be scaled up. In this work, we propose siphon-based supply of saline water over the evaporator that enables scale up of the desalination system to a size significantly higher than the capillary rise height of the hydrophilic evaporator while preventing salt accumulation on the evaporator. The composite siphon comprises insulating fabric wick and a metallic grooved surface for localizing heat to evaporate a thin layer of saline liquid over the evaporator. We perform heat and mass transfer analysis to show that the thermal-to-vapor efficiency depends on the inlet mass flow rate and air gap between the evaporator and the condenser. We propose a methodology to passively control the mass flow rate to maximize the thermal to vapor efficiency at different input heat flux and initial concentration of the brine. A grooved condenser avoids mixing of brine and the freshwater, even at air gaps as low as 2 mm. A siphon-assisted 10-stage desalination system with a footprint area 15 cm 15 cm and an air gap of 2 mm is shown to have a high water productivity flux of 5.73 Lm−2 h−1 from 3.5 wt% saline water at an applied heat flux 1000 W/m2, which increases to a record high distillate flux of ∼6.23 Lm−2 h−1 and thermal to water collection efficiency of ∼423 % for a 15-stage system. The ability of the desalination system to maintain a high-water productivity flux even when the evaporator area is increased by 4 times demonstrates its scalability to achieve higher desalinated water productivity rate.
期刊介绍:
Desalination is a scholarly journal that focuses on the field of desalination materials, processes, and associated technologies. It encompasses a wide range of disciplines and aims to publish exceptional papers in this area.
The journal invites submissions that explicitly revolve around water desalting and its applications to various sources such as seawater, groundwater, and wastewater. It particularly encourages research on diverse desalination methods including thermal, membrane, sorption, and hybrid processes.
By providing a platform for innovative studies, Desalination aims to advance the understanding and development of desalination technologies, promoting sustainable solutions for water scarcity challenges.