{"title":"Non-linear cascade control with gain-scheduling and startup control strategy study for thermionic space reactor TOPAZ-II","authors":"","doi":"10.1016/j.pnucene.2024.105514","DOIUrl":null,"url":null,"abstract":"<div><div>The TOPAZ-II thermionic space reactor system, which was designed by the Soviet Union, is characterized by its high degree of nonlinearity and positive temperature reactivity feedback. The thermionic space reactor exhibits characteristics of high inertia and significant delay in controlling its electrical power and outlet temperature. The simple PID controller is difficult to achieve good performance. To carry out controller design for thermionic space reactor, the simulation platform for thermionic space reactor is developed based on coupling between reactor system thermal-hydraulic code RESYS and control system simulator in this study. After that, based on the cascade control strategy and gain-scheduling, the reactor thermal controller, electric power controller, outlet temperature controller applicable for the full power range is designed with transfer function model and frequency domain analysis method. To validate the nonlinear electric power controller performance, the continuous minor step disturbances, major step disturbances, and ramp variation of electric power setpoint is simulated. The performance of outlet temperature controller is verified with the simulation result of step and ramp variation of outlet temperature setpoint. Thereafter, the start-up process of the thermionic space reactor TOPAZ-II is simulated and analyzed. The simulation result reveals that the controller designed in this paper can overcome the nonlinearity of the thermionic space reactor system and has good performance throughout the entire power range. Compared to traditional simple PID controller, the cascade controller has better performance and can achieve good control performance even in situations where simple PID controllers cannot function properly.</div></div>","PeriodicalId":20617,"journal":{"name":"Progress in Nuclear Energy","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Nuclear Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0149197024004645","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The TOPAZ-II thermionic space reactor system, which was designed by the Soviet Union, is characterized by its high degree of nonlinearity and positive temperature reactivity feedback. The thermionic space reactor exhibits characteristics of high inertia and significant delay in controlling its electrical power and outlet temperature. The simple PID controller is difficult to achieve good performance. To carry out controller design for thermionic space reactor, the simulation platform for thermionic space reactor is developed based on coupling between reactor system thermal-hydraulic code RESYS and control system simulator in this study. After that, based on the cascade control strategy and gain-scheduling, the reactor thermal controller, electric power controller, outlet temperature controller applicable for the full power range is designed with transfer function model and frequency domain analysis method. To validate the nonlinear electric power controller performance, the continuous minor step disturbances, major step disturbances, and ramp variation of electric power setpoint is simulated. The performance of outlet temperature controller is verified with the simulation result of step and ramp variation of outlet temperature setpoint. Thereafter, the start-up process of the thermionic space reactor TOPAZ-II is simulated and analyzed. The simulation result reveals that the controller designed in this paper can overcome the nonlinearity of the thermionic space reactor system and has good performance throughout the entire power range. Compared to traditional simple PID controller, the cascade controller has better performance and can achieve good control performance even in situations where simple PID controllers cannot function properly.
期刊介绍:
Progress in Nuclear Energy is an international review journal covering all aspects of nuclear science and engineering. In keeping with the maturity of nuclear power, articles on safety, siting and environmental problems are encouraged, as are those associated with economics and fuel management. However, basic physics and engineering will remain an important aspect of the editorial policy. Articles published are either of a review nature or present new material in more depth. They are aimed at researchers and technically-oriented managers working in the nuclear energy field.
Please note the following:
1) PNE seeks high quality research papers which are medium to long in length. Short research papers should be submitted to the journal Annals in Nuclear Energy.
2) PNE reserves the right to reject papers which are based solely on routine application of computer codes used to produce reactor designs or explain existing reactor phenomena. Such papers, although worthy, are best left as laboratory reports whereas Progress in Nuclear Energy seeks papers of originality, which are archival in nature, in the fields of mathematical and experimental nuclear technology, including fission, fusion (blanket physics, radiation damage), safety, materials aspects, economics, etc.
3) Review papers, which may occasionally be invited, are particularly sought by the journal in these fields.