{"title":"Impact of random geometric errors in an elliptical superconducting magnet with application to a compact heavy-ion synchrotron","authors":"Ye Yang , Kota Mizushima","doi":"10.1016/j.nima.2024.169981","DOIUrl":null,"url":null,"abstract":"<div><div>A compact heavy-ion synchrotron is under development for next-generation cancer therapy. A superconducting magnet is designed with a main dipole field of 3.5 T and a field error less than 5 <span><math><mo>×</mo></math></span> 10<sup>−4</sup> to maintain compactness. The coil is wound directly with monolithic Nb-Ti wire on a curved elliptical mandrel, comprising 22 laminated layers to achieve the desired magnetic field. Given the critical need for field quality, it is imperative to determine the tolerance of coil fabrication and to devise a method to eliminate field error during the design stage. This paper presents a numerical investigation of possible random geometric errors stemming from fabrication and assembly tolerances in a curved elliptical superconducting magnet. We first provide an analytical formulation derived in a complex plane to estimate the field error of a straight elliptical coil. We then conduct a Monte Carlo simulation to assess cases involving misalignment of individual wires and coil block sectors. Additionally, we compare simulation results with field measurements obtained from a short model magnet tested previously to predict potential random errors in manufacturing. Finally, we calculate the beam dynamic aperture to assess the effects of random geometric errors on beam loss using Monte Carlo simulation results. This method enables the prediction of tolerances for fabricating high-quality high-field magnets and aids in making design decisions concerning the utilization of active shim coils.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1069 ","pages":"Article 169981"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900224009070","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
A compact heavy-ion synchrotron is under development for next-generation cancer therapy. A superconducting magnet is designed with a main dipole field of 3.5 T and a field error less than 5 10−4 to maintain compactness. The coil is wound directly with monolithic Nb-Ti wire on a curved elliptical mandrel, comprising 22 laminated layers to achieve the desired magnetic field. Given the critical need for field quality, it is imperative to determine the tolerance of coil fabrication and to devise a method to eliminate field error during the design stage. This paper presents a numerical investigation of possible random geometric errors stemming from fabrication and assembly tolerances in a curved elliptical superconducting magnet. We first provide an analytical formulation derived in a complex plane to estimate the field error of a straight elliptical coil. We then conduct a Monte Carlo simulation to assess cases involving misalignment of individual wires and coil block sectors. Additionally, we compare simulation results with field measurements obtained from a short model magnet tested previously to predict potential random errors in manufacturing. Finally, we calculate the beam dynamic aperture to assess the effects of random geometric errors on beam loss using Monte Carlo simulation results. This method enables the prediction of tolerances for fabricating high-quality high-field magnets and aids in making design decisions concerning the utilization of active shim coils.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.