{"title":"Low-cost portable sensor for rapid and sensitive detection of Pb2+ ions using capacitance sensing integrated with microfluidic enrichment","authors":"Niloufar Amin,&nbsp;Jiangang Chen,&nbsp;Qing Cao,&nbsp;Haochen Qi,&nbsp;Jian Zhang,&nbsp;Qiang He,&nbsp;Jie Jayne Wu","doi":"10.1007/s00604-024-06798-z","DOIUrl":null,"url":null,"abstract":"<div><p>Lead ion (Pb<sup>2+</sup>) pollution is a critical global issue due to its ability to accumulate in the human body, resulting in severe health problems. Despite extensive research efforts devoted to the detection of Pb<sup>2+</sup> contamination, practical, rapid, and field-deployable sensors for Pb<sup>2+</sup> is yet to be developed to effectively safeguard the environment and public health. Herein, a label-free affinity-based sensing device is developed based on printed circuit board (PCB) for low-cost, easy-to-use, and real-time on-site detection of Pb<sup>2+</sup> ions. The sensors are prepared by forming a self-assembled monolayer of glutathione (GSH) on the surface of gold-plated PCB electrodes, which serves as a molecular probe to recognize Pb<sup>2+</sup>. Rapid and sensitive detection is achieved by using capacitance sensing integrated with microfluidic enrichment. The sensor’s interfacial capacitance is used to indicate specific binding, while the capacitance reading process simultaneously induces alternating current electrothermal (ACET) acceleration of analyte’s travel towards the probes. Thus, the enrichment and detection are integrated into a single step, making pre-concentration unnecessary and shortening the assay time to 30 s. This Pb<sup>2+</sup> sensor has demonstrated one of the lowest limits of detection reported so far (1.85 fM) with a linear range of 0.01–10 pM. To evaluate the sensor’s specificity, non-target metal ions are tested, all showing negligible responses. Testing of tap water sample also yields reasonable results, validating the sensor’s robustness. The above-mentioned features, together with a commercial portable readout, make this sensor well-suited for point-of-use Pb<sup>2+</sup> detection at low cost.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"191 11","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06798-z","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Lead ion (Pb2+) pollution is a critical global issue due to its ability to accumulate in the human body, resulting in severe health problems. Despite extensive research efforts devoted to the detection of Pb2+ contamination, practical, rapid, and field-deployable sensors for Pb2+ is yet to be developed to effectively safeguard the environment and public health. Herein, a label-free affinity-based sensing device is developed based on printed circuit board (PCB) for low-cost, easy-to-use, and real-time on-site detection of Pb2+ ions. The sensors are prepared by forming a self-assembled monolayer of glutathione (GSH) on the surface of gold-plated PCB electrodes, which serves as a molecular probe to recognize Pb2+. Rapid and sensitive detection is achieved by using capacitance sensing integrated with microfluidic enrichment. The sensor’s interfacial capacitance is used to indicate specific binding, while the capacitance reading process simultaneously induces alternating current electrothermal (ACET) acceleration of analyte’s travel towards the probes. Thus, the enrichment and detection are integrated into a single step, making pre-concentration unnecessary and shortening the assay time to 30 s. This Pb2+ sensor has demonstrated one of the lowest limits of detection reported so far (1.85 fM) with a linear range of 0.01–10 pM. To evaluate the sensor’s specificity, non-target metal ions are tested, all showing negligible responses. Testing of tap water sample also yields reasonable results, validating the sensor’s robustness. The above-mentioned features, together with a commercial portable readout, make this sensor well-suited for point-of-use Pb2+ detection at low cost.

Graphical abstract

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用集成微流控富集技术的电容传感技术,快速灵敏地检测 Pb2+ 离子的低成本便携式传感器。
铅离子(Pb2+)污染是一个严重的全球性问题,因为它能够在人体内蓄积,导致严重的健康问题。尽管人们对 Pb2+ 污染的检测进行了广泛的研究,但实用、快速和可现场部署的 Pb2+ 传感器仍有待开发,以有效保护环境和公众健康。本文开发了一种基于印刷电路板(PCB)的无标记亲和式传感装置,用于低成本、易使用和实时现场检测 Pb2+ 离子。传感器的制备方法是在镀金印刷电路板电极表面形成谷胱甘肽(GSH)自组装单层,作为识别 Pb2+ 的分子探针。利用电容传感与微流体富集技术相结合,实现了快速灵敏的检测。传感器的界面电容用于指示特异性结合,而电容读取过程同时会引起分析物向探针移动的交变电流电热(ACET)加速。这种 Pb2+ 传感器的检测限(1.85 fM)是迄今为止报告的最低检测限之一,线性范围为 0.01-10 pM。为了评估传感器的特异性,还对非目标金属离子进行了测试,结果显示所有反应都可以忽略不计。对自来水样品的测试也得出了合理的结果,验证了传感器的稳健性。上述特点加上商用便携式读数器,使该传感器非常适合于低成本的 Pb2+ 点检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
A portable colorimetric immunosensor for highly sensitive point-of-care testing of leather artifacts Photoelectrochemical immunosensor for chloramphenicol detection based on cation exchange reaction-mediacted photocurrent enhancement of ZnIn2S4/TiO2/Ti3C2 MXene coupled with controlled-release strategy Magnetic poly(phages) encoded probes-based dual-mode assay for rapid determination of live Escherichia coli and Hafnia paralvei based on microfluidic chip and ATP bioluminescence meter. In-situ oxidative polymerization of dopamine triggered by CuO2 in acidic condition and application in “turn-off” sensing Bi2S3/BiOCl heterojunction-based photoelectrochemical aptasensor for ultrasensitive assay of fumonisin B1 via signal amplification with in situ grown Ag2S quantum dots
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1