Yu Kuei Lin, Wen Ye, Emily Hepworth, Annika Agni, Austin M Matus, Anneliese J Flatt, James A M Shaw, Michael R Rickels, Stephanie A Amiel, Jane Speight
{"title":"Characterising impaired awareness of hypoglycaemia and associated risks through HypoA-Q: findings from a T1D Exchange cohort.","authors":"Yu Kuei Lin, Wen Ye, Emily Hepworth, Annika Agni, Austin M Matus, Anneliese J Flatt, James A M Shaw, Michael R Rickels, Stephanie A Amiel, Jane Speight","doi":"10.1007/s00125-024-06310-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims/hypothesis: </strong>We aimed to: (1) externally validate the five-item Hypoglycaemia Awareness Questionnaire (HypoA-Q) impaired awareness subscale (HypoA-Q IA); (2) examine how impaired awareness of hypoglycaemia (IAH) relates to the risk of severe hypoglycaemia and level 2 hypoglycaemia; and (3) identify factors associated with IAH.</p><p><strong>Methods: </strong>Nationwide survey of T1D Exchange registrants was conducted to collect data on demographics, 6 month severe-hypoglycaemia history, hypoglycaemia awareness status (via HypoA-Q IA, the Gold instrument and the Clarke instrument) and continuous glucose monitor (CGM) measures. The Clarke hypoglycaemia awareness factor (Clarke-HAF) was calculated to exclude severe-hypoglycaemia history items. Analyses included Cronbach's α, Spearman correlations and logistic regression.</p><p><strong>Results: </strong>Valid survey responses were collected from N=1580 adults with type 1 diabetes (median age, 44 years; 52% female participants; median HbA<sub>1c</sub>, 48 mmol/mol [6.5%]). Of these, 94% of participants were using CGMs and 69% were using hybrid closed-loop (HCL) systems; 30% had at least one severe-hypoglycaemia episode in the past 6 months. The HypoA-Q IA had satisfactory internal reliability (α=0.79) and construct validity. Higher HypoA-Q IA scores were independently associated with greater risk of severe hypoglycaemia (p<0.001), performing comparably to the Gold instrument and the Clarke-HAF instrument. HypoA-Q IA-determined IAH was independently associated with 88% higher odds of developing severe hypoglycaemia (p<0.001) and twofold higher odds for spending ≥1% of time in level 2 hypoglycaemia (p=0.011). Higher age and longer diabetes duration were associated with higher IAH risk (p<0.001). CGM and HCL use was associated with lower IAH risk (p<0.001).</p><p><strong>Conclusions/interpretation: </strong>The HypoA-Q IA is a brief, valid and reliable tool for assessing IAH in today's technology-oriented era. IAH was independently associated with severe hypoglycaemia and level 2 hypoglycaemia in a cohort with high prevalence of advanced diabetes technology use and HbA<sub>1c</sub> within the recommended range. CGM and HCL use was related to lower IAH risk.</p>","PeriodicalId":11164,"journal":{"name":"Diabetologia","volume":" ","pages":""},"PeriodicalIF":8.4000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00125-024-06310-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Aims/hypothesis: We aimed to: (1) externally validate the five-item Hypoglycaemia Awareness Questionnaire (HypoA-Q) impaired awareness subscale (HypoA-Q IA); (2) examine how impaired awareness of hypoglycaemia (IAH) relates to the risk of severe hypoglycaemia and level 2 hypoglycaemia; and (3) identify factors associated with IAH.
Methods: Nationwide survey of T1D Exchange registrants was conducted to collect data on demographics, 6 month severe-hypoglycaemia history, hypoglycaemia awareness status (via HypoA-Q IA, the Gold instrument and the Clarke instrument) and continuous glucose monitor (CGM) measures. The Clarke hypoglycaemia awareness factor (Clarke-HAF) was calculated to exclude severe-hypoglycaemia history items. Analyses included Cronbach's α, Spearman correlations and logistic regression.
Results: Valid survey responses were collected from N=1580 adults with type 1 diabetes (median age, 44 years; 52% female participants; median HbA1c, 48 mmol/mol [6.5%]). Of these, 94% of participants were using CGMs and 69% were using hybrid closed-loop (HCL) systems; 30% had at least one severe-hypoglycaemia episode in the past 6 months. The HypoA-Q IA had satisfactory internal reliability (α=0.79) and construct validity. Higher HypoA-Q IA scores were independently associated with greater risk of severe hypoglycaemia (p<0.001), performing comparably to the Gold instrument and the Clarke-HAF instrument. HypoA-Q IA-determined IAH was independently associated with 88% higher odds of developing severe hypoglycaemia (p<0.001) and twofold higher odds for spending ≥1% of time in level 2 hypoglycaemia (p=0.011). Higher age and longer diabetes duration were associated with higher IAH risk (p<0.001). CGM and HCL use was associated with lower IAH risk (p<0.001).
Conclusions/interpretation: The HypoA-Q IA is a brief, valid and reliable tool for assessing IAH in today's technology-oriented era. IAH was independently associated with severe hypoglycaemia and level 2 hypoglycaemia in a cohort with high prevalence of advanced diabetes technology use and HbA1c within the recommended range. CGM and HCL use was related to lower IAH risk.
期刊介绍:
Diabetologia, the authoritative journal dedicated to diabetes research, holds high visibility through society membership, libraries, and social media. As the official journal of the European Association for the Study of Diabetes, it is ranked in the top quartile of the 2019 JCR Impact Factors in the Endocrinology & Metabolism category. The journal boasts dedicated and expert editorial teams committed to supporting authors throughout the peer review process.