A graph and diffusion theory-based approach for localization and recovery of false data injection attacks in power systems

IF 3.3 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC Electric Power Systems Research Pub Date : 2024-11-05 DOI:10.1016/j.epsr.2024.111184
Yixuan He, Jingyu Wang, Chen Yang, Dongyuan Shi
{"title":"A graph and diffusion theory-based approach for localization and recovery of false data injection attacks in power systems","authors":"Yixuan He,&nbsp;Jingyu Wang,&nbsp;Chen Yang,&nbsp;Dongyuan Shi","doi":"10.1016/j.epsr.2024.111184","DOIUrl":null,"url":null,"abstract":"<div><div>False Data Injection Attacks (FDIAs) pose a serious threat to power systems by interfering with state estimation and jeopardizing their safety and reliability. Detecting and recovering from FDIAs is thus critical for maintaining power system integrity. The increasing integration of renewable energy sources and the extensive use of power electronic devices introduce significant randomness in both power generation and loads, leading to significant power fluctuations and dynamic changes in power flows. These variations challenge the accuracy of existing FDIA detection and recovery methods. To address these challenges, an innovative data recovery framework is proposed, comprising two key stages: the FDIA localization stage and the FDIA data recovery stage. In the first stage, a Line Message Passing Neural Network (LMPNN) based FDIA localization model is employed to precisely identify the attacked data and generate a mask input for the recovery stage. In the data recovery stage, an FDIA data recovery model, named Denoising Diffusion Graph Models (DDGM), is designed to recover data with minimal error while conforming to the physical laws of the grid. Both models utilize node graph and line graph representations to depict measurements on buses and branches. By leveraging an optimized graph neural network, and inviting a loop-structured framework that combines a denoising diffusion model with a graph neural network these models effectively extract data features and inherent dynamic properties, enabling superior localization of FDIAs both in node and edge spaces and ensuring accurate recovery of compromised data even in the presence of high uncertainty and significant power fluctuations. By incorporating physical laws through a customized loss function embedding Kirchhoff’s circuit laws into the training process of DDGM, the model ensures the recovered data to be physically consistent with power system dynamics. Experimental validations on IEEE 39-bus and 118-bus test systems, under conditions of high fluctuations in generation and loads, demonstrate that the proposed models outperform existing methods, achieving significant improvements in accuracy and robustness.</div></div>","PeriodicalId":50547,"journal":{"name":"Electric Power Systems Research","volume":"239 ","pages":"Article 111184"},"PeriodicalIF":3.3000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electric Power Systems Research","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378779624010708","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

False Data Injection Attacks (FDIAs) pose a serious threat to power systems by interfering with state estimation and jeopardizing their safety and reliability. Detecting and recovering from FDIAs is thus critical for maintaining power system integrity. The increasing integration of renewable energy sources and the extensive use of power electronic devices introduce significant randomness in both power generation and loads, leading to significant power fluctuations and dynamic changes in power flows. These variations challenge the accuracy of existing FDIA detection and recovery methods. To address these challenges, an innovative data recovery framework is proposed, comprising two key stages: the FDIA localization stage and the FDIA data recovery stage. In the first stage, a Line Message Passing Neural Network (LMPNN) based FDIA localization model is employed to precisely identify the attacked data and generate a mask input for the recovery stage. In the data recovery stage, an FDIA data recovery model, named Denoising Diffusion Graph Models (DDGM), is designed to recover data with minimal error while conforming to the physical laws of the grid. Both models utilize node graph and line graph representations to depict measurements on buses and branches. By leveraging an optimized graph neural network, and inviting a loop-structured framework that combines a denoising diffusion model with a graph neural network these models effectively extract data features and inherent dynamic properties, enabling superior localization of FDIAs both in node and edge spaces and ensuring accurate recovery of compromised data even in the presence of high uncertainty and significant power fluctuations. By incorporating physical laws through a customized loss function embedding Kirchhoff’s circuit laws into the training process of DDGM, the model ensures the recovered data to be physically consistent with power system dynamics. Experimental validations on IEEE 39-bus and 118-bus test systems, under conditions of high fluctuations in generation and loads, demonstrate that the proposed models outperform existing methods, achieving significant improvements in accuracy and robustness.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于图和扩散理论的电力系统虚假数据注入攻击定位和恢复方法
虚假数据注入攻击(FDIAs)会干扰状态估计,危及电力系统的安全性和可靠性,从而对电力系统构成严重威胁。因此,检测和恢复 FDIA 对维护电力系统的完整性至关重要。可再生能源的日益集成和电力电子设备的广泛使用为发电和负载带来了显著的随机性,从而导致电力的大幅波动和电力流的动态变化。这些变化对现有 FDIA 检测和恢复方法的准确性提出了挑战。为应对这些挑战,我们提出了一个创新的数据恢复框架,包括两个关键阶段:FDIA 定位阶段和 FDIA 数据恢复阶段。在第一阶段,采用基于线消息传递神经网络(LMPNN)的 FDIA 定位模型来精确识别受攻击数据,并为恢复阶段生成掩码输入。在数据恢复阶段,设计了一种名为去噪扩散图模型(DDGM)的 FDIA 数据恢复模型,以最小的误差恢复数据,同时符合网格的物理规律。这两种模型都利用节点图和线图表示法来描述总线和分支上的测量结果。这些模型利用优化的图神经网络,并采用循环结构框架,将去噪扩散模型与图神经网络相结合,从而有效提取数据特征和固有的动态特性,在节点和边缘空间中实现出色的 FDIA 定位,并确保即使在存在高不确定性和显著功率波动的情况下也能准确恢复受损数据。通过在 DDGM 的训练过程中嵌入基尔霍夫电路定律的定制损失函数,该模型结合了物理定律,确保恢复的数据在物理上与电力系统动态一致。在发电和负载波动较大的条件下,在 IEEE 39 总线和 118 总线测试系统上进行的实验验证表明,所提出的模型优于现有方法,在准确性和鲁棒性方面都有显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electric Power Systems Research
Electric Power Systems Research 工程技术-工程:电子与电气
CiteScore
7.50
自引率
17.90%
发文量
963
审稿时长
3.8 months
期刊介绍: Electric Power Systems Research is an international medium for the publication of original papers concerned with the generation, transmission, distribution and utilization of electrical energy. The journal aims at presenting important results of work in this field, whether in the form of applied research, development of new procedures or components, orginal application of existing knowledge or new designapproaches. The scope of Electric Power Systems Research is broad, encompassing all aspects of electric power systems. The following list of topics is not intended to be exhaustive, but rather to indicate topics that fall within the journal purview. • Generation techniques ranging from advances in conventional electromechanical methods, through nuclear power generation, to renewable energy generation. • Transmission, spanning the broad area from UHV (ac and dc) to network operation and protection, line routing and design. • Substation work: equipment design, protection and control systems. • Distribution techniques, equipment development, and smart grids. • The utilization area from energy efficiency to distributed load levelling techniques. • Systems studies including control techniques, planning, optimization methods, stability, security assessment and insulation coordination.
期刊最新文献
Investigation of GLM detections of negative continuing currents observed by high-speed video and narrow-band 777 nm photometer Business and pricing models for smart energy at building level: A Review Enhanced resilience in smart grids: A neural network-based detection of data integrity attacks using improved war strategy optimization Improved electrogeometric model for shielding failure evaluation of double-circuit UHVAC transmission lines based on leader propagation simulations Demand flexibility in hydrogen production by incorporating electrical and physical parameters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1