Development of Ti-Zr-Nb-Ta-Ag high entropy alloy for dental implants: In vitro corrosion behavior, antibacterial effect, and surface characteristics

IF 4.3 3区 材料科学 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY Materials Chemistry and Physics Pub Date : 2024-11-01 DOI:10.1016/j.matchemphys.2024.130114
M.A. Hussein , A. Madhan Kumar , M.A. Azeem , N. Ankah , S. Saravanan
{"title":"Development of Ti-Zr-Nb-Ta-Ag high entropy alloy for dental implants: In vitro corrosion behavior, antibacterial effect, and surface characteristics","authors":"M.A. Hussein ,&nbsp;A. Madhan Kumar ,&nbsp;M.A. Azeem ,&nbsp;N. Ankah ,&nbsp;S. Saravanan","doi":"10.1016/j.matchemphys.2024.130114","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a new biological high-entropy alloy (Bio-HEA) composed of 35Ti-35Zr-20Nb-5Ta-5Ag (at. %) for potential dental implant applications. The Bio-HEA underwent processing for various durations of mechanical alloying, followed by compaction and sintering. The processed Bio-HEA was tested for corrosion resistance in an artificial saliva medium, antibacterial properties, and surface characteristics. Surface topography and wettability were investigated using atomic force microscopy, surface profilometry, and contact angle measurements. Mechanical alloying, X-ray diffraction, and scanning electron microscopy revealed the formation of a solid-solution Bio-HEA with body-centered cubic crystal structures, with phase variations depending on the processing conditions. The Bio-HEA exhibited significantly higher microhardness values (4.38 GPa and 5.35 GPa) than commercial pure titanium (CPTi) and Ti-6Al-4V alloy, respectively. An increased ball-milling time resulted in higher microhardness for Bio-HEA and enhanced in vitro corrosion resistance in artificial saliva compared to CPTi. This was evidenced by a significant nobler shift of approximately 200 mV in the corrosion potential, with a prominent decrease of approximately two orders of magnitude in the corrosion current density and a higher charge transfer resistance. Additionally, the Bio-HEA demonstrated a lower contact angle compared to that of the Ti-6Al-4V alloy and CPTi. The Bio-HEA achieved antibacterial efficiencies of 91.76 % and 93.0 % compared to Ti-6Al-4V alloy and CPTi, respectively. The enhanced microhardness, antibacterial properties, in vitro corrosion resistance in artificial saliva, and wettability of Bio-HEA compared to commercial Ti-6Al-4V alloy and CPTi makes it a promising candidate for dental bioimplant applications.</div></div>","PeriodicalId":18227,"journal":{"name":"Materials Chemistry and Physics","volume":"329 ","pages":"Article 130114"},"PeriodicalIF":4.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Chemistry and Physics","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0254058424012422","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a new biological high-entropy alloy (Bio-HEA) composed of 35Ti-35Zr-20Nb-5Ta-5Ag (at. %) for potential dental implant applications. The Bio-HEA underwent processing for various durations of mechanical alloying, followed by compaction and sintering. The processed Bio-HEA was tested for corrosion resistance in an artificial saliva medium, antibacterial properties, and surface characteristics. Surface topography and wettability were investigated using atomic force microscopy, surface profilometry, and contact angle measurements. Mechanical alloying, X-ray diffraction, and scanning electron microscopy revealed the formation of a solid-solution Bio-HEA with body-centered cubic crystal structures, with phase variations depending on the processing conditions. The Bio-HEA exhibited significantly higher microhardness values (4.38 GPa and 5.35 GPa) than commercial pure titanium (CPTi) and Ti-6Al-4V alloy, respectively. An increased ball-milling time resulted in higher microhardness for Bio-HEA and enhanced in vitro corrosion resistance in artificial saliva compared to CPTi. This was evidenced by a significant nobler shift of approximately 200 mV in the corrosion potential, with a prominent decrease of approximately two orders of magnitude in the corrosion current density and a higher charge transfer resistance. Additionally, the Bio-HEA demonstrated a lower contact angle compared to that of the Ti-6Al-4V alloy and CPTi. The Bio-HEA achieved antibacterial efficiencies of 91.76 % and 93.0 % compared to Ti-6Al-4V alloy and CPTi, respectively. The enhanced microhardness, antibacterial properties, in vitro corrosion resistance in artificial saliva, and wettability of Bio-HEA compared to commercial Ti-6Al-4V alloy and CPTi makes it a promising candidate for dental bioimplant applications.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开发用于牙科植入物的 Ti-Zr-Nb-Ta-Ag 高熵合金:体外腐蚀行为、抗菌效果和表面特性
本研究介绍了一种新型生物高熵合金(Bio-HEA),其成分为 35Ti-35Zr-20Nb-5Ta-5Ag(at.生物高熵合金经过不同时间的机械合金化处理,然后进行压实和烧结。对加工后的 Bio-HEA 在人工唾液介质中的耐腐蚀性、抗菌性能和表面特性进行了测试。使用原子力显微镜、表面轮廓仪和接触角测量法对表面形貌和润湿性进行了研究。通过机械合金化、X 射线衍射和扫描电子显微镜,发现形成了具有体心立方晶体结构的固溶体 Bio-HEA,其相变化取决于加工条件。Bio-HEA 的显微硬度值(4.38 GPa 和 5.35 GPa)明显高于商用纯钛(CPTi)和 Ti-6Al-4V 合金。与 CPTi 相比,增加球磨时间可提高 Bio-HEA 的显微硬度,并增强其在人工唾液中的体外耐腐蚀性。具体表现为腐蚀电位发生了约 200 mV 的明显偏移,腐蚀电流密度显著降低了约两个数量级,电荷转移电阻更高。此外,与 Ti-6Al-4V 合金和 CPTi 相比,Bio-HEA 的接触角更小。与 Ti-6Al-4V 合金和 CPTi 相比,Bio-HEA 的抗菌效率分别达到 91.76 % 和 93.0 %。与商用 Ti-6Al-4V 合金和 CPTi 相比,Bio-HEA 的微硬度、抗菌性能、在人工唾液中的体外耐腐蚀性和润湿性均有所提高,因此有望成为牙科生物种植体的候选材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Materials Chemistry and Physics
Materials Chemistry and Physics 工程技术-材料科学:综合
CiteScore
8.70
自引率
4.30%
发文量
1515
审稿时长
69 days
期刊介绍: Materials Chemistry and Physics is devoted to short communications, full-length research papers and feature articles on interrelationships among structure, properties, processing and performance of materials. The Editors welcome manuscripts on thin films, surface and interface science, materials degradation and reliability, metallurgy, semiconductors and optoelectronic materials, fine ceramics, magnetics, superconductors, specialty polymers, nano-materials and composite materials.
期刊最新文献
Synergistic effects of Carbon@MoS2 core-shell nanostructures on charge dynamics for future optoelectronic applications Optimization of atomic layer deposited Pt-shell thickness of PtCu3@Pt/C catalyst for oxygen reduction reaction Influence of core fluorination on the phase properties of fan-like azobenzene based supramolecules, their cis-trans photoisomerization and photoluminescence dynamics Investigation of structural, thermal, and electrical properties of sodium-doped oxynitride glass-ceramics Synthesis and application of Ho³⁺ doped BaGd₂ZnO₅ nanophosphors for enhanced latent fingerprint development and poroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1