{"title":"Fast OCT-Based Needle Tracking for Retinal Microsurgery Using Dynamic Spiral Scanning","authors":"Pengwei Xu;Mouloud Ourak;Gianni Borghesan;Emmanuel Vander Poorten","doi":"10.1109/TMRB.2024.3464693","DOIUrl":null,"url":null,"abstract":"Retinal microsurgery is crucial for treating various ocular diseases, but challenging due to the structure size, physiological tremor and limited depth perception. This study aims to develop an innovative real-time needle tracking system that utilizes only a small amount of Optical Coherence Tomography (OCT) A-scans. We introduce a spiral scanning pattern, that is dynamically updated to efficiently capture the needle tip and the retina area with 2000 A-scans. An imaging pipeline is proposed that initiates with an initial Region of Interest (ROI) identification, followed by image segmentation, 3D reconstruction, and needle pose estimation. The ROI is dynamically adjusted to keep the needle tip centrally within the spiral scan, facilitating tracking at clinically relevant speeds. Preliminary testing on phantom eye models demonstrated that our system can maintain an average tracking error of 0.04 mm in spatial coordinates and an error of 0.06 mm in estimating the distance between the needle tip and the retina. These results suggest the system’s potential to enhance surgical outcomes by providing surgeons with improved depth perception and precise, real-time feedback. By efficiently utilizing spirally sampled OCT data, this system sets the groundwork for future integrations of real-time 4D imaging and physiological motion detection capabilities.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10684764/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Retinal microsurgery is crucial for treating various ocular diseases, but challenging due to the structure size, physiological tremor and limited depth perception. This study aims to develop an innovative real-time needle tracking system that utilizes only a small amount of Optical Coherence Tomography (OCT) A-scans. We introduce a spiral scanning pattern, that is dynamically updated to efficiently capture the needle tip and the retina area with 2000 A-scans. An imaging pipeline is proposed that initiates with an initial Region of Interest (ROI) identification, followed by image segmentation, 3D reconstruction, and needle pose estimation. The ROI is dynamically adjusted to keep the needle tip centrally within the spiral scan, facilitating tracking at clinically relevant speeds. Preliminary testing on phantom eye models demonstrated that our system can maintain an average tracking error of 0.04 mm in spatial coordinates and an error of 0.06 mm in estimating the distance between the needle tip and the retina. These results suggest the system’s potential to enhance surgical outcomes by providing surgeons with improved depth perception and precise, real-time feedback. By efficiently utilizing spirally sampled OCT data, this system sets the groundwork for future integrations of real-time 4D imaging and physiological motion detection capabilities.