Elliot Pressman, Joshua H Weinberg, Ammad A Baig, Gersham J Rainone, Samantha Schimmel Ba, Joshua Vignolles-Jeong, Teagen Smith, Patrick Youssef, Jason M Davies, Adnan H Siddiqui, Elad I Levy, Waldo R Guerrero, Maxim Mokin, Kunal Vakharia
{"title":"Validity of Woven EndoBridge sizing based on the device-to-aneurysm volume ratio.","authors":"Elliot Pressman, Joshua H Weinberg, Ammad A Baig, Gersham J Rainone, Samantha Schimmel Ba, Joshua Vignolles-Jeong, Teagen Smith, Patrick Youssef, Jason M Davies, Adnan H Siddiqui, Elad I Levy, Waldo R Guerrero, Maxim Mokin, Kunal Vakharia","doi":"10.1177/15910199241298327","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Woven EndoBridge (WEB) is a treatment modality available for the treatment of intracranial aneurysms, specifically beneficial in wide-necked bifurcation aneurysms. Conventional sizing methods rely on the manipulation of aneurysm width and height measurements. This results in frequent need for re-sizing after initial WEB insertion attempts. Previous studies have suggested that volume-based sizing may decrease this rate.</p><p><strong>Methods: </strong>We conducted a multicenter retrospective cohort study in three complex vascular centers in the United States from 1 January 2020 to 30 June 2023. All patients who underwent attempted aneurysmal WEB embolization were included. Using three-dimensional angiogram reconstructions, we measured the aneurysm volume. We calculated the WEB volume and measured the WEB-aneurysm volume (WAVe) ratio. The primary outcome was whether a WEB required re-sizing.</p><p><strong>Results: </strong>A total of 133 cases were identified, 114 correctly sized and 19 incorrectly sized. Twelve patients (9.0%) required additional stent placement during WEB insertion. One patient (0.8%) had WEB abandonment. There were no differences in demographic or baseline characteristics between the size/re-sizing cohorts aside from aneurysm location (\"other\" and basilar locations increased the rate of re-sizing). The median WAVe ratio in our appropriately sized cohort was 0.997 (interquartile range (IQR) 0.826, 1.30) versus 1.14 in our re-sizing cohort (IQR 0.734, 1.51; <i>p</i> = 0.728). Using logistic regression, we identified a WAVe ratio ranging from 0.76 to 1.24 yielding > 80% probability of a successful sizing with 95% confidence.</p><p><strong>Conclusions: </strong>Incorporating volume-based measurements in aneurysm embolization with WEBs may improve rates of re-sizing but has an unclear effect on aneurysm occlusion. A WAVe ratio of 0.76-1.24 provides the greatest probability of appropriate initial WEB sizing.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11562453/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241298327","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The Woven EndoBridge (WEB) is a treatment modality available for the treatment of intracranial aneurysms, specifically beneficial in wide-necked bifurcation aneurysms. Conventional sizing methods rely on the manipulation of aneurysm width and height measurements. This results in frequent need for re-sizing after initial WEB insertion attempts. Previous studies have suggested that volume-based sizing may decrease this rate.
Methods: We conducted a multicenter retrospective cohort study in three complex vascular centers in the United States from 1 January 2020 to 30 June 2023. All patients who underwent attempted aneurysmal WEB embolization were included. Using three-dimensional angiogram reconstructions, we measured the aneurysm volume. We calculated the WEB volume and measured the WEB-aneurysm volume (WAVe) ratio. The primary outcome was whether a WEB required re-sizing.
Results: A total of 133 cases were identified, 114 correctly sized and 19 incorrectly sized. Twelve patients (9.0%) required additional stent placement during WEB insertion. One patient (0.8%) had WEB abandonment. There were no differences in demographic or baseline characteristics between the size/re-sizing cohorts aside from aneurysm location ("other" and basilar locations increased the rate of re-sizing). The median WAVe ratio in our appropriately sized cohort was 0.997 (interquartile range (IQR) 0.826, 1.30) versus 1.14 in our re-sizing cohort (IQR 0.734, 1.51; p = 0.728). Using logistic regression, we identified a WAVe ratio ranging from 0.76 to 1.24 yielding > 80% probability of a successful sizing with 95% confidence.
Conclusions: Incorporating volume-based measurements in aneurysm embolization with WEBs may improve rates of re-sizing but has an unclear effect on aneurysm occlusion. A WAVe ratio of 0.76-1.24 provides the greatest probability of appropriate initial WEB sizing.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...