Advanced Noise-Resistant Electrocardiography Classification Using Hybrid Wavelet-Median Denoising and a Convolutional Neural Network.

IF 3.4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL Sensors Pub Date : 2024-10-31 DOI:10.3390/s24217033
Aditya Pal, Hari Mohan Rai, Saurabh Agarwal, Neha Agarwal
{"title":"Advanced Noise-Resistant Electrocardiography Classification Using Hybrid Wavelet-Median Denoising and a Convolutional Neural Network.","authors":"Aditya Pal, Hari Mohan Rai, Saurabh Agarwal, Neha Agarwal","doi":"10.3390/s24217033","DOIUrl":null,"url":null,"abstract":"<p><p>The classification of ECG signals is a critical process because it guides the diagnosis of the proper treatment process for the patient. However, any form of disturbance with ECG signals can be highly conspicuous because of the mechanics involved in data acquisition from living beings, which has a significant impact on the classification procedure. The purpose of this research work is to advance ECG signal classification results by employing numerous denoising methods and, in turn, boost the accuracy of cardiovascular diagnoses. To simulate realistic conditions, we added various types of noise to ECG data, including Gaussian, salt and pepper, speckle, uniform, and exponential noise. To overcome the interference of noise from environments in the obtained ECG signals, we employed wavelet transform, median filter, Gaussian filter, and the hybrid of the wavelet and median filters. The proposed hybrid denoising method has better results than the other methods because of the use of wavelet multi-scale analysis and the ability of the median filter to avoid the loss of vital ECG characteristics. Thus, despite a certain proximity in the values, the hybrid method is significantly more accurate and reliable, as evidenced by the mean squared error (MSE), mean absolute error (MAE), R-squared, and Pearson correlation coefficient. More specifically, the hybrid approach provided an MSE of 0.0012 and an MAE of 0.025, the R-squared value for this study was 0.98, and the Pearson correlation coefficient was 0.99, which provides a very good resemblance to the original ECG confirmation. The proposed classification model is based on the modified lightweight CNN or MLCNN that was trained using the noisy and the denoised data. The findings demonstrated that by applying the denoised data, the testing accuracy, precision, recall, and F1 scores achieved 0.92, 0.91, 0.90, and 0.91 for the datasets, while the noisy data achieved 0.80, 0.78, 0.82, and 0.80, respectively. In this study, the signal quality and denoising methods were found to enhance ECG signal classification and diagnostic accuracy while encouraging proper preprocessing in future studies and applications for real-time ECG for cardiac care.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"24 21","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548400/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s24217033","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The classification of ECG signals is a critical process because it guides the diagnosis of the proper treatment process for the patient. However, any form of disturbance with ECG signals can be highly conspicuous because of the mechanics involved in data acquisition from living beings, which has a significant impact on the classification procedure. The purpose of this research work is to advance ECG signal classification results by employing numerous denoising methods and, in turn, boost the accuracy of cardiovascular diagnoses. To simulate realistic conditions, we added various types of noise to ECG data, including Gaussian, salt and pepper, speckle, uniform, and exponential noise. To overcome the interference of noise from environments in the obtained ECG signals, we employed wavelet transform, median filter, Gaussian filter, and the hybrid of the wavelet and median filters. The proposed hybrid denoising method has better results than the other methods because of the use of wavelet multi-scale analysis and the ability of the median filter to avoid the loss of vital ECG characteristics. Thus, despite a certain proximity in the values, the hybrid method is significantly more accurate and reliable, as evidenced by the mean squared error (MSE), mean absolute error (MAE), R-squared, and Pearson correlation coefficient. More specifically, the hybrid approach provided an MSE of 0.0012 and an MAE of 0.025, the R-squared value for this study was 0.98, and the Pearson correlation coefficient was 0.99, which provides a very good resemblance to the original ECG confirmation. The proposed classification model is based on the modified lightweight CNN or MLCNN that was trained using the noisy and the denoised data. The findings demonstrated that by applying the denoised data, the testing accuracy, precision, recall, and F1 scores achieved 0.92, 0.91, 0.90, and 0.91 for the datasets, while the noisy data achieved 0.80, 0.78, 0.82, and 0.80, respectively. In this study, the signal quality and denoising methods were found to enhance ECG signal classification and diagnostic accuracy while encouraging proper preprocessing in future studies and applications for real-time ECG for cardiac care.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用混合小波-中值去噪和卷积神经网络进行高级抗噪心电图分类
心电信号的分类是一个关键过程,因为它能指导诊断,为患者提供正确的治疗过程。然而,由于从活人身上获取数据涉及到力学问题,心电信号的任何形式干扰都会非常明显,这对分类程序有很大影响。这项研究工作的目的是通过采用多种去噪方法来提高心电信号分类结果,进而提高心血管诊断的准确性。为了模拟现实条件,我们在心电图数据中加入了各种类型的噪声,包括高斯噪声、椒盐噪声、斑点噪声、均匀噪声和指数噪声。为了克服环境噪声对心电图信号的干扰,我们采用了小波变换、中值滤波器、高斯滤波器以及小波滤波器和中值滤波器的混合滤波器。由于使用了小波多尺度分析和中值滤波器能够避免重要心电图特征的丢失,因此所提出的混合去噪方法比其他方法效果更好。因此,尽管数值上有一定的接近性,但从均方误差(MSE)、平均绝对误差(MAE)、R 方和皮尔逊相关系数来看,混合方法明显更准确可靠。更具体地说,混合方法的 MSE 为 0.0012,MAE 为 0.025,本研究的 R 平方值为 0.98,皮尔逊相关系数为 0.99,与原始心电图确认结果非常相似。所提出的分类模型是基于改进的轻量级 CNN 或 MLCNN,该模型使用噪声数据和去噪数据进行训练。研究结果表明,通过应用去噪数据,数据集的测试准确度、精确度、召回率和 F1 分数分别达到了 0.92、0.91、0.90 和 0.91,而噪声数据则分别达到了 0.80、0.78、0.82 和 0.80。本研究发现,信号质量和去噪方法可提高心电图信号分类和诊断准确性,同时鼓励在今后的研究和应用中对实时心电图进行适当的预处理,以用于心脏护理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
A Review of Cutting-Edge Sensor Technologies for Improved Flood Monitoring and Damage Assessment. Optimizing the Agricultural Internet of Things (IoT) with Edge Computing and Low-Altitude Platform Stations. A Study of the Effect of Temperature on the Capacitance Characteristics of a Metal-μhemisphere Resonant Gyroscope. Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty. Passive and Active Exoskeleton Solutions: Sensors, Actuators, Applications, and Recent Trends.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1