The role of amino acid PET in radiotherapy target volume delineation for adult-type diffuse gliomas: A review of the literature

IF 5.5 2区 医学 Q1 HEMATOLOGY Critical reviews in oncology/hematology Pub Date : 2024-11-08 DOI:10.1016/j.critrevonc.2024.104552
Patrick J. Horsley , Dale L. Bailey , Geoffrey Schembri , Edward Hsiao , James Drummond , Michael F. Back
{"title":"The role of amino acid PET in radiotherapy target volume delineation for adult-type diffuse gliomas: A review of the literature","authors":"Patrick J. Horsley ,&nbsp;Dale L. Bailey ,&nbsp;Geoffrey Schembri ,&nbsp;Edward Hsiao ,&nbsp;James Drummond ,&nbsp;Michael F. Back","doi":"10.1016/j.critrevonc.2024.104552","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To summarise existing literature examining amino acid positron emission tomography (AA-PET) for radiotherapy target volume delineation in patients with gliomas.</div></div><div><h3>Methods</h3><div>Systematic search of MEDLINE and EMBASE databases.</div></div><div><h3>Results</h3><div>Twenty studies met inclusion criteria. Studies comparing MRI- and AA-PET- derived target volumes consistently found these to be complementary. Across studies, AA-PET was a strong predictor of the site of subsequent relapse. In studies examining AA-PET-guided radiotherapy at standard doses, including one study using reduced margins, survival outcomes were similar to historical cohorts whose volumes were generated using MRI alone. Four prospective single-arm trials examining AA-PET-guided dose-escalated radiotherapy reported mixed results. The two trials that used both a higher biologically-effective dose and boost-volumes defined using both MRI and AA-PET reported promising outcomes.</div></div><div><h3>Conclusion</h3><div>AA-PET is a promising complementary tool to MRI for radiotherapy target volume delineation, with potential benefits requiring further validation including margin reduction and facilitation of dose-escalation.</div></div>","PeriodicalId":11358,"journal":{"name":"Critical reviews in oncology/hematology","volume":"205 ","pages":"Article 104552"},"PeriodicalIF":5.5000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical reviews in oncology/hematology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1040842824002956","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To summarise existing literature examining amino acid positron emission tomography (AA-PET) for radiotherapy target volume delineation in patients with gliomas.

Methods

Systematic search of MEDLINE and EMBASE databases.

Results

Twenty studies met inclusion criteria. Studies comparing MRI- and AA-PET- derived target volumes consistently found these to be complementary. Across studies, AA-PET was a strong predictor of the site of subsequent relapse. In studies examining AA-PET-guided radiotherapy at standard doses, including one study using reduced margins, survival outcomes were similar to historical cohorts whose volumes were generated using MRI alone. Four prospective single-arm trials examining AA-PET-guided dose-escalated radiotherapy reported mixed results. The two trials that used both a higher biologically-effective dose and boost-volumes defined using both MRI and AA-PET reported promising outcomes.

Conclusion

AA-PET is a promising complementary tool to MRI for radiotherapy target volume delineation, with potential benefits requiring further validation including margin reduction and facilitation of dose-escalation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氨基酸 PET 在成人型弥漫性胶质瘤放疗靶区划分中的作用:文献综述。
目的:总结研究氨基酸正电子发射断层扫描(AA-PET)用于胶质瘤患者放疗靶区划分的现有文献:方法:系统检索 MEDLINE 和 EMBASE 数据库:结果:20 项研究符合纳入标准。比较核磁共振成像和 AA-PET 得出的靶体积的研究一致认为两者具有互补性。在所有研究中,AA-PET是预测后续复发部位的有力指标。在以标准剂量进行AA-PET引导放疗的研究中,包括一项使用缩小边缘的研究,生存结果与仅使用MRI生成体积的历史队列相似。四项前瞻性单臂试验对AA-PET引导的剂量递增放疗进行了研究,结果不一。两项试验同时使用了较高的生物有效剂量,并使用MRI和AA-PET确定了增量,结果令人鼓舞:结论:AA-PET是核磁共振成像在放射治疗靶区划分方面一种很有前途的补充工具,其潜在优势需要进一步验证,包括减少边缘和促进剂量递增。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
11.00
自引率
3.20%
发文量
213
审稿时长
55 days
期刊介绍: Critical Reviews in Oncology/Hematology publishes scholarly, critical reviews in all fields of oncology and hematology written by experts from around the world. Critical Reviews in Oncology/Hematology is the Official Journal of the European School of Oncology (ESO) and the International Society of Liquid Biopsy.
期刊最新文献
Editorial Board Erratum to “Unleashing precision: A review of targeted approaches in pleural mesothelioma” [Crit. Rev. Oncol./Hematol. 203C (2024) 104481] Corrigendum to “The emerging HER2 landscape in Colorectal Cancer: The key to unveil the future treatment algorithm?” [Crit. Rev. Oncol./Hematol. 204 (2024) 104515] Corrigendum to “Navigating the complexity of PI3K/AKT pathway in HER-2 negative breast cancer: Biomarkers and beyond” [Crit. Rev. Oncol./Hematol. 200C (2024) 104404] Corrigendum to “Prevalence of treatment-related adverse events (TRAEs) with antibody-drug conjugates in metastatic breast cancer patients: A systematic review and meta-analysis” [Crit. Rev. Oncol./Hematol. 204 (2024) 104527]
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1