Detection of Abnormality in Deterministic Compressive Sensed Breast Thermograms Using Bilateral Asymmetry

IF 5.6 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Instrumentation and Measurement Pub Date : 2024-10-30 DOI:10.1109/TIM.2024.3488144
Ankita Dey;Sreeraman Rajan;Ioannis Lambadaris
{"title":"Detection of Abnormality in Deterministic Compressive Sensed Breast Thermograms Using Bilateral Asymmetry","authors":"Ankita Dey;Sreeraman Rajan;Ioannis Lambadaris","doi":"10.1109/TIM.2024.3488144","DOIUrl":null,"url":null,"abstract":"The increased number of breast cancer cases worldwide necessitates the development of early breast abnormality detection techniques. Thermography serves as a promising imaging modality that can be used as an adjunctive tool with mammography for early breast abnormality detection. It can be particularly useful for breast abnormality detection in developing or underdeveloped countries that have a limited number of medical professionals and low-power processing units for diagnosis. Appropriate compression of breast thermal images reduces the data storage expenses and computational complexity of the algorithms for breast abnormality detection using thermography. Therefore, we are motivated to use deterministic compressive sensing (CS) for the compression of the red-plane extracted from the breast thermograms and detecting breast abnormality in the compressed domain using the compressed red plane. The deterministic CS technique employs a given deterministic binary block diagonal (DBBD) matrix that acts as a low-pass filter and downsampler and preserves the features needed for abnormality detection. We propose a bilateral asymmetry analysis-based breast abnormality detection technique in the compressed domain. A performance analysis of compressed domain breast abnormality detection technique with red-plane thermograms compressed using CS and non-CS compression techniques at different compression ratios (CRs) along with an analysis of computational complexities is presented. A comprehensive analysis of the performance of compressed domain breast abnormality detection is also explored when different types of common medical image noises (Gaussian, salt and pepper, and speckle noise) at different noise levels are present.","PeriodicalId":13341,"journal":{"name":"IEEE Transactions on Instrumentation and Measurement","volume":"73 ","pages":"1-13"},"PeriodicalIF":5.6000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Instrumentation and Measurement","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10739346/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The increased number of breast cancer cases worldwide necessitates the development of early breast abnormality detection techniques. Thermography serves as a promising imaging modality that can be used as an adjunctive tool with mammography for early breast abnormality detection. It can be particularly useful for breast abnormality detection in developing or underdeveloped countries that have a limited number of medical professionals and low-power processing units for diagnosis. Appropriate compression of breast thermal images reduces the data storage expenses and computational complexity of the algorithms for breast abnormality detection using thermography. Therefore, we are motivated to use deterministic compressive sensing (CS) for the compression of the red-plane extracted from the breast thermograms and detecting breast abnormality in the compressed domain using the compressed red plane. The deterministic CS technique employs a given deterministic binary block diagonal (DBBD) matrix that acts as a low-pass filter and downsampler and preserves the features needed for abnormality detection. We propose a bilateral asymmetry analysis-based breast abnormality detection technique in the compressed domain. A performance analysis of compressed domain breast abnormality detection technique with red-plane thermograms compressed using CS and non-CS compression techniques at different compression ratios (CRs) along with an analysis of computational complexities is presented. A comprehensive analysis of the performance of compressed domain breast abnormality detection is also explored when different types of common medical image noises (Gaussian, salt and pepper, and speckle noise) at different noise levels are present.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用双侧不对称检测确定性压缩感应乳房热图中的异常情况
随着全球乳腺癌病例的增加,有必要开发早期乳腺异常检测技术。热成像技术是一种很有前途的成像模式,可作为乳房 X 线照相术的辅助工具,用于早期乳房异常检测。在发展中国家或欠发达国家,由于医疗专业人员数量有限,用于诊断的处理设备功率较低,热成像技术在乳腺异常检测方面尤其有用。对乳腺热图像进行适当压缩,可减少数据存储费用,并降低利用热成像技术检测乳腺异常的算法的计算复杂性。因此,我们采用确定性压缩传感(CS)技术来压缩从乳房热成像图中提取的红平面,并利用压缩后的红平面检测压缩域中的乳房异常。确定性压缩传感技术采用给定的确定性二进制对角矩阵(DBBD)作为低通滤波器和下采样器,并保留异常检测所需的特征。我们提出了一种基于双边不对称分析的压缩域乳腺异常检测技术。在不同的压缩比(CR)下,使用 CS 和非 CS 压缩技术对红平面热图进行压缩,对压缩域乳腺异常检测技术进行了性能分析,并对计算复杂性进行了分析。此外,还探讨了当存在不同类型、不同噪声水平的常见医学图像噪声(高斯噪声、椒盐噪声和斑点噪声)时,压缩域乳腺异常检测性能的综合分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Instrumentation and Measurement
IEEE Transactions on Instrumentation and Measurement 工程技术-工程:电子与电气
CiteScore
9.00
自引率
23.20%
发文量
1294
审稿时长
3.9 months
期刊介绍: Papers are sought that address innovative solutions to the development and use of electrical and electronic instruments and equipment to measure, monitor and/or record physical phenomena for the purpose of advancing measurement science, methods, functionality and applications. The scope of these papers may encompass: (1) theory, methodology, and practice of measurement; (2) design, development and evaluation of instrumentation and measurement systems and components used in generating, acquiring, conditioning and processing signals; (3) analysis, representation, display, and preservation of the information obtained from a set of measurements; and (4) scientific and technical support to establishment and maintenance of technical standards in the field of Instrumentation and Measurement.
期刊最新文献
Front Cover Double Resonant Cavity Enhanced Photoacoustic Gas Sensor for Acetylene Detection GFA-Net: Global Feature Aggregation Network Based on Contrastive Learning for Breast Lesion Automated Segmentation in Ultrasound Images A Bayesian Inferred Health Prognosis and State of Charge Estimation for Power Batteries A High-Accuracy Fault Detection Method Using Swarm Intelligence Optimization Entropy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1