Determination of furmonertinib in human plasma and cerebrospinal fluid by UPLC-MS/MS: Application in lung cancer patients with and without brain metastasis

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography B Pub Date : 2024-11-01 DOI:10.1016/j.jchromb.2024.124375
Hongxin Qie , Cong Song , Yuxiang Xu , Haopeng Zhao , Wenlin Gong , Peiyuan Wang , Xiaonan Gao , Jinglin Gao , Zhangying Feng , Mingxia Wang
{"title":"Determination of furmonertinib in human plasma and cerebrospinal fluid by UPLC-MS/MS: Application in lung cancer patients with and without brain metastasis","authors":"Hongxin Qie ,&nbsp;Cong Song ,&nbsp;Yuxiang Xu ,&nbsp;Haopeng Zhao ,&nbsp;Wenlin Gong ,&nbsp;Peiyuan Wang ,&nbsp;Xiaonan Gao ,&nbsp;Jinglin Gao ,&nbsp;Zhangying Feng ,&nbsp;Mingxia Wang","doi":"10.1016/j.jchromb.2024.124375","DOIUrl":null,"url":null,"abstract":"<div><div>Furmonertinib (AST2818) is a selective epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) being developed for the treatment of patients with EGFR mutation-positive non-small cell lung cancer. Quantification of furmonertinib in plasma and cerebrospinal fluid (CSF) can be used to assess penetration of furmonertinib into the central nervous system (CNS). This paper described ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) methods for quantification of furmonertinib in human plasma and CSF. Sample separation was achieved on a Kinetex C<sub>18</sub> column (100 mm × 2.1 mm, 2.6 μm) after simple protein precipitation with acetonitrile. The mobile phase was composed of acetonitrile and 5 mM ammonium acetate with 0.2 % formic acid in water. Quantitative ion pairs were <em>m</em>/<em>z</em> 569.3 → 72.2 for furmonertinib and <em>m</em>/<em>z</em> 526.5 → 72.2 for aumolertinib, which was used as the internal standard (IS). The calibration curves showed good linearity (r<sup>2</sup> &gt; 0.99) over concentration range of 0.5–200 ng/mL(plasma sample) and 0.05–30 ng/mL(CSF sample). The precision (RSD) was ≤7.86 %, and the accuracy fell within the range of 96.2 %–109.3 %, all meeting acceptance criteria. The matrix effect was from 94.3 % to 102.1 %. The recovery of analytes fell within the range of 93.3 %–98.9 %. The established analytical methods showed great sensitivity, simplicity, accuracy and reliability for the analysis of furmonertinib in human plasma and CSF. This assay would be helpful to predict the effectiveness and toxicities of furmonertinib in the pursuit of precision medicine for lung cancer patients.</div></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1248 ","pages":"Article 124375"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224003842","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Furmonertinib (AST2818) is a selective epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) being developed for the treatment of patients with EGFR mutation-positive non-small cell lung cancer. Quantification of furmonertinib in plasma and cerebrospinal fluid (CSF) can be used to assess penetration of furmonertinib into the central nervous system (CNS). This paper described ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) methods for quantification of furmonertinib in human plasma and CSF. Sample separation was achieved on a Kinetex C18 column (100 mm × 2.1 mm, 2.6 μm) after simple protein precipitation with acetonitrile. The mobile phase was composed of acetonitrile and 5 mM ammonium acetate with 0.2 % formic acid in water. Quantitative ion pairs were m/z 569.3 → 72.2 for furmonertinib and m/z 526.5 → 72.2 for aumolertinib, which was used as the internal standard (IS). The calibration curves showed good linearity (r2 > 0.99) over concentration range of 0.5–200 ng/mL(plasma sample) and 0.05–30 ng/mL(CSF sample). The precision (RSD) was ≤7.86 %, and the accuracy fell within the range of 96.2 %–109.3 %, all meeting acceptance criteria. The matrix effect was from 94.3 % to 102.1 %. The recovery of analytes fell within the range of 93.3 %–98.9 %. The established analytical methods showed great sensitivity, simplicity, accuracy and reliability for the analysis of furmonertinib in human plasma and CSF. This assay would be helpful to predict the effectiveness and toxicities of furmonertinib in the pursuit of precision medicine for lung cancer patients.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用 UPLC-MS/MS 法测定人血浆和脑脊液中的呋莫替尼--在有脑转移和无脑转移肺癌患者中的应用
呋莫替尼 (AST2818) 是一种选择性表皮生长因子受体 (EGFR) 酪氨酸激酶抑制剂 (TKI),目前正在开发用于治疗 EGFR 突变阳性的非小细胞肺癌患者。血浆和脑脊液(CSF)中呋莫替尼的定量可用于评估呋莫替尼对中枢神经系统(CNS)的渗透。本文介绍了超高效液相色谱-串联质谱(UPLC-MS/MS)方法,用于定量检测人血浆和脑脊液中的呋莫尼替尼。样品经乙腈简单蛋白质沉淀后,在 Kinetex C18 色谱柱(100 mm × 2.1 mm, 2.6 μm)上分离。流动相为乙腈和 5 mM 乙酸铵加 0.2 % 甲酸水溶液。定量离子对为 m/z 569.3 → 72.2(呋莫替尼)和 m/z 526.5 → 72.2(奥莫替尼),后者被用作内标(IS)。在 0.5-200 纳克/毫升(血浆样品)和 0.05-30 纳克/毫升(脑脊液样品)的浓度范围内,校准曲线显示出良好的线性关系(r2 > 0.99)。精密度(RSD)≤7.86 %,准确度在 96.2 %-109.3 % 范围内,均符合接受标准。基质效应为 94.3 % 至 102.1 %。分析物的回收率在 93.3 % 至 98.9 % 之间。所建立的分析方法在分析人血浆和脑脊液中的呋喃替尼时显示出极高的灵敏度、简便性、准确性和可靠性。该检测方法有助于预测呋莫尼替尼的疗效和毒性,从而实现肺癌患者的精准医疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
期刊最新文献
Development and validation of a robust RP-HPLC method to quantitate residual 2-mercaptoethylamine in drug product formulations containing amino acid additives. Unraveling the molecular mechanism of aqueous extract of Sargentodoxa cuneata against ulcerative colitis from serum metabolomics and bioinformatics perspectives. Green RP-HPLC method for the estimation of carfilzomib in bulk, protein nanocarriers and human plasma: Application of chemometrics and Monte-Carlo simulations Methylated magnetic covalent organic framework for sample preparation and LC-MS/MS detection of 12 tadalafil analogs in dietary supplements Progress in the technology of solvent flotation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1