Development and validation of the placenta-QUS model for the detection of placenta-mediated diseases using quantitative ultrasound measurements: An Ex Vivo proof-of-concept study
Farah Deeba , Ricky Hu , Victoria Lessoway , Jefferson Terry , Denise Pugash , Chantal Mayer , Jennifer Hutcheon , Robert Rohling
{"title":"Development and validation of the placenta-QUS model for the detection of placenta-mediated diseases using quantitative ultrasound measurements: An Ex Vivo proof-of-concept study","authors":"Farah Deeba , Ricky Hu , Victoria Lessoway , Jefferson Terry , Denise Pugash , Chantal Mayer , Jennifer Hutcheon , Robert Rohling","doi":"10.1016/j.placenta.2024.11.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Placenta-mediated diseases are associated with structural changes in the placenta. Quantitative Ultrasound (QUS) imaging measures the acoustic properties of the tissue, which are correlated to the underlying tissue structure. We aimed to develop and validate a diagnostic prediction model using QUS measurements for pre-eclampsia (PE) and small-for-gestational-age (SGA) fetuses/neonates.</div></div><div><h3>Methods</h3><div>For this prospective case-control study, placentas were collected from a group of women who delivered via cesarean section at BC Women's Hospital, Vancouver, Canada. Ultrasound data were collected and processed to compute three QUS parameters, namely, attenuation coefficient estimate (ACE), integrated backscatter coefficient (IBC), and effective scatterer diameter (ESD) from the placentas. We developed a logistic regression model using QUS parameters as predictors. The primary outcome was the occurrence of SGA and PE.</div></div><div><h3>Results</h3><div>The dataset consisted of 47 placentas, of which 25 placentas were complicated by SGA/PE. The final placenta-QUS model included quadratic and interaction terms of ACE, IBC, and ESD parameters. The placenta-QUS model was well-calibrated, with a calibration slope of 0.99 (0.57–1.05) and a calibration intercept of 0.003 (−0.02 − 0.22). The model predicted the SGA/PE complicated pregnancies with an apparent Area Under the Receive Operating Characteristic Curve (AUROC) of 0.89 (95 % CI: 0.78–0.98). The optimism-adjusted AUROC was 0.88 (95 % CI: 0.78–0.98).</div></div><div><h3>Discussion</h3><div>A model for SGA and PE has been developed using QUS measures from the placenta <em>ex vivo</em>. The model showed promising performance in detecting SGA/PE. Future studies will be performed to assess the model performance using QUS measures <em>in utero</em>.</div></div>","PeriodicalId":20203,"journal":{"name":"Placenta","volume":"158 ","pages":"Pages 293-300"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Placenta","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0143400424007677","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DEVELOPMENTAL BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Placenta-mediated diseases are associated with structural changes in the placenta. Quantitative Ultrasound (QUS) imaging measures the acoustic properties of the tissue, which are correlated to the underlying tissue structure. We aimed to develop and validate a diagnostic prediction model using QUS measurements for pre-eclampsia (PE) and small-for-gestational-age (SGA) fetuses/neonates.
Methods
For this prospective case-control study, placentas were collected from a group of women who delivered via cesarean section at BC Women's Hospital, Vancouver, Canada. Ultrasound data were collected and processed to compute three QUS parameters, namely, attenuation coefficient estimate (ACE), integrated backscatter coefficient (IBC), and effective scatterer diameter (ESD) from the placentas. We developed a logistic regression model using QUS parameters as predictors. The primary outcome was the occurrence of SGA and PE.
Results
The dataset consisted of 47 placentas, of which 25 placentas were complicated by SGA/PE. The final placenta-QUS model included quadratic and interaction terms of ACE, IBC, and ESD parameters. The placenta-QUS model was well-calibrated, with a calibration slope of 0.99 (0.57–1.05) and a calibration intercept of 0.003 (−0.02 − 0.22). The model predicted the SGA/PE complicated pregnancies with an apparent Area Under the Receive Operating Characteristic Curve (AUROC) of 0.89 (95 % CI: 0.78–0.98). The optimism-adjusted AUROC was 0.88 (95 % CI: 0.78–0.98).
Discussion
A model for SGA and PE has been developed using QUS measures from the placenta ex vivo. The model showed promising performance in detecting SGA/PE. Future studies will be performed to assess the model performance using QUS measures in utero.
期刊介绍:
Placenta publishes high-quality original articles and invited topical reviews on all aspects of human and animal placentation, and the interactions between the mother, the placenta and fetal development. Topics covered include evolution, development, genetics and epigenetics, stem cells, metabolism, transport, immunology, pathology, pharmacology, cell and molecular biology, and developmental programming. The Editors welcome studies on implantation and the endometrium, comparative placentation, the uterine and umbilical circulations, the relationship between fetal and placental development, clinical aspects of altered placental development or function, the placental membranes, the influence of paternal factors on placental development or function, and the assessment of biomarkers of placental disorders.