Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model.

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Biomedical optics express Pub Date : 2024-10-21 eCollection Date: 2024-11-01 DOI:10.1364/BOE.530708
Benjamin Stern, Damien Gatinel
{"title":"Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model.","authors":"Benjamin Stern, Damien Gatinel","doi":"10.1364/BOE.530708","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, an in vitro comparison of the optical performances of three models (spherical, aberration-neutral, and aberration-correcting) of monofocal intraocular lenses (IOLs) is proposed. A comprehensive model is employed, encompassing a wide range of corneal models and aperture sizes, reflecting the high variability of corneal spherical aberrations (SA) and pupil sizes in both normal and postoperative refractive corneal surgery populations. Analysis of average through-focus modulation transfer function (MTF) curves reveals significant differences in optical performance attributable to pupil size and corneal SA. These differences depend on the IOL model and affects MTFmax (representing contrast at best focus), depth of focus, refractive error tolerance, and the effective power of the lens.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 11","pages":"6433-6448"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563339/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.530708","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, an in vitro comparison of the optical performances of three models (spherical, aberration-neutral, and aberration-correcting) of monofocal intraocular lenses (IOLs) is proposed. A comprehensive model is employed, encompassing a wide range of corneal models and aperture sizes, reflecting the high variability of corneal spherical aberrations (SA) and pupil sizes in both normal and postoperative refractive corneal surgery populations. Analysis of average through-focus modulation transfer function (MTF) curves reveals significant differences in optical performance attributable to pupil size and corneal SA. These differences depend on the IOL model and affects MTFmax (representing contrast at best focus), depth of focus, refractive error tolerance, and the effective power of the lens.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
瞳孔大小和角膜球面像差对单焦点眼内透镜性能的影响:一个实验模型。
在这项研究中,提出了对三种型号(球面、中性像差和像差校正)的单焦点眼内透镜(IOLs)的光学性能进行体外比较。所采用的综合模型包含多种角膜模型和孔径大小,反映了正常和术后屈光性角膜手术人群中角膜球面像差(SA)和瞳孔大小的高变异性。对平均通焦调制传递函数(MTF)曲线的分析表明,瞳孔大小和角膜球差在光学性能上存在显著差异。这些差异取决于人工晶体的型号,并影响 MTFmax(代表最佳聚焦时的对比度)、聚焦深度、屈光误差容限和镜片的有效功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
期刊最新文献
Super resolution reconstruction of fluorescence microscopy images by a convolutional network with physical priors. Physics-guided deep learning-based real-time image reconstruction of Fourier-domain optical coherence tomography. On bench evaluation of intraocular lenses: performance of a commercial interferometer. Predictive coding compressive sensing optical coherence tomography hardware implementation. Development of silicone-based phantoms for biomedical optics from 400 to 1550 nm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1