Interevaluator reliability of a tool for measuring body height in adult intensive care patients

IF 1.1 Q3 NURSING Enfermeria Intensiva Pub Date : 2024-10-01 DOI:10.1016/j.enfi.2024.01.002
H.A. Payán-Salcedo , J.L. Estela-Zape , L.P. Chanchi-Quintero , E.C. Wilches-Luna
{"title":"Interevaluator reliability of a tool for measuring body height in adult intensive care patients","authors":"H.A. Payán-Salcedo ,&nbsp;J.L. Estela-Zape ,&nbsp;L.P. Chanchi-Quintero ,&nbsp;E.C. Wilches-Luna","doi":"10.1016/j.enfi.2024.01.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The calculation of body height in the intensive care unit is essential for obtaining the ideal body weight, which is used to program the tidal volume and establish objective and effective pulmonary ventilation. The objective of the study was to determine the interrater reliability of a tool for measuring body height in adult patients in an intensive care unit (ICU) in southwestern Colombia.</div></div><div><h3>Methods</h3><div>This cross-sectional observational study was conducted between January and May 2021, following the recommendations of the COSMIN protocol. Two physiotherapists in the roles of observer/evaluator measured the heights of 106 patients upon admission to the ICU with a previously designed. The sample size was calculated based on Pearson's correlation coefficient. For interrater reliability, the intraclass correlation coefficient (ICC) was used, and Bland–Altman analysis was used to assess concordance. The 95% confidence interval was established, and a P value &lt;0.05 indicated statistical significance.</div></div><div><h3>Results</h3><div>A total of 106 individuals with a mean age of 59.3 years were included; the mean body height was 158.5 cm for women. The interrater reliability of the measurement of height was excellent (global ICC of 0.99, <em>P</em> = 0.000), and an almost perfect positive correlation was obtained between the raters for both women and men (<em>R</em> = 0.99).</div></div><div><h3>Conclusions</h3><div>Excellent interrater/interobserver reliability was obtained for the measurement of body height in the ICU. This research highlights the importance of protocolizing the measurement of height in critical patients with valid and reliable instruments.</div></div>","PeriodicalId":43993,"journal":{"name":"Enfermeria Intensiva","volume":"35 4","pages":"Pages 299-307"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enfermeria Intensiva","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1130239924000221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The calculation of body height in the intensive care unit is essential for obtaining the ideal body weight, which is used to program the tidal volume and establish objective and effective pulmonary ventilation. The objective of the study was to determine the interrater reliability of a tool for measuring body height in adult patients in an intensive care unit (ICU) in southwestern Colombia.

Methods

This cross-sectional observational study was conducted between January and May 2021, following the recommendations of the COSMIN protocol. Two physiotherapists in the roles of observer/evaluator measured the heights of 106 patients upon admission to the ICU with a previously designed. The sample size was calculated based on Pearson's correlation coefficient. For interrater reliability, the intraclass correlation coefficient (ICC) was used, and Bland–Altman analysis was used to assess concordance. The 95% confidence interval was established, and a P value <0.05 indicated statistical significance.

Results

A total of 106 individuals with a mean age of 59.3 years were included; the mean body height was 158.5 cm for women. The interrater reliability of the measurement of height was excellent (global ICC of 0.99, P = 0.000), and an almost perfect positive correlation was obtained between the raters for both women and men (R = 0.99).

Conclusions

Excellent interrater/interobserver reliability was obtained for the measurement of body height in the ICU. This research highlights the importance of protocolizing the measurement of height in critical patients with valid and reliable instruments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
成人重症监护患者身高测量工具的评估者内部可靠性
背景重症监护室中身高的计算对于获得理想体重至关重要,理想体重可用于潮气量的设定以及建立客观有效的肺通气。本研究的目的是确定哥伦比亚西南部重症监护室(ICU)成年患者身高测量工具的交互可靠性。两名物理治疗师分别扮演观察者和评估者的角色,在 106 名患者进入重症监护室时用事先设计好的身高测量器测量他们的身高。样本量根据皮尔逊相关系数计算得出。对于评估者之间的可靠性,使用了类内相关系数(ICC),并使用布兰德-阿尔特曼分析法评估一致性。结果 共纳入 106 人,平均年龄为 59.3 岁;女性的平均身高为 158.5 厘米。身高测量的评定者间可靠性极佳(总体 ICC 为 0.99,P = 0.000),男女评定者之间几乎完全正相关(R = 0.99)。这项研究强调了使用有效、可靠的仪器对危重病人进行身高测量的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
23.10%
发文量
48
期刊介绍: Enfermería Intensiva es el medio de comunicación por antonomasia para todos los profesionales de enfermería españoles que desarrollan su actividad profesional en las unidades de cuidados intensivos o en cualquier otro lugar donde se atiende al paciente crítico. Enfermería Intensiva publica cuatro números al año, cuyos temas son específicos para la enfermería de cuidados intensivos. Es la única publicación en español con carácter nacional y está indexada en prestigiosas bases de datos como International Nursing Index, MEDLINE, Índice de Enfermería, Cuiden, Índice Médico Español, Toxline, etc.
期刊最新文献
Punción ecoguiada versus técnica tradicional para la extracción de gasometrías arteriales en adultos: una revisión sistemática Perspectiva de género en la realización de la higiene en cuidados intensivos cardiológicos Barriers to reporting adverse events from the perspective of ICU nurses: A mixed-method study Drug interactions in a coronary care unit: Adversity or therapeutic success? Utilización de un sistema de valoración para la asignación de recurso humano en el transporte intrahospitalario del paciente ingresado en una unidad de cuidados intensivos
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1