{"title":"Influence of structural parameters on the performance of fluid oscillators","authors":"Wenhui Zhai , Yuxin Fan","doi":"10.1016/j.euromechflu.2024.11.002","DOIUrl":null,"url":null,"abstract":"<div><div>The fluid oscillator, relying on the Coanda effect, is a flow control device that can alter the direction or velocity of a jet both spatially and temporally. The fuel injection device based on a fluid oscillator significantly enhances atomization and spatial dispersion performance compared to a direct-spray nozzle. However, when used in high heat load afterburners with aviation kerosene as the working medium, oxidative coking issues may arise. To address this, it is recommended to use premixed rich fuel-vapor as the working fluid in order to reduce the residence time of fuel in the oscillator. This study investigates the flow rate and frequency variation of ideal air (simulated gas phase fuel) as it moves through a double feedback channel fluid oscillator with varying thicknesses and outlet throat widths. Experimental and numerical simulation methods are employed. And the influence mechanism is analyzed through an examination of the flow field structure within the cavity of the fluid oscillator. The results indicate that increasing the thickness of the fluid oscillator leads to a higher outlet tangential velocity and deflection angle, while simultaneously decreasing the oscillation frequency. Conversely, widening the fluid oscillator throat results in a decrease in tangential velocity, deflection angle, and oscillation frequency. The performance of the fluid oscillator reaches a critical threshold when the outlet throat is square. As thickness increases, the rate of decrease in oscillation frequency and the rate of increase in tangential velocity both slow down. Furthermore, the maximum deflection angle of the airflow at the oscillator outlet reaches a critical value at a thickness of 3.375 mm, beyond which the trend of increasing deflection angle also slows. When the thickness of the oscillator is less than 3.375 mm, mass flow is the predominant driving factor for airflow deflection in the mixing chamber. In contrast, when the thickness is greater than or equal to 3.375 mm, pressure becomes the primary driving factor for this deflection.</div></div>","PeriodicalId":11985,"journal":{"name":"European Journal of Mechanics B-fluids","volume":"109 ","pages":"Pages 367-377"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Mechanics B-fluids","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0997754624001560","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 0
Abstract
The fluid oscillator, relying on the Coanda effect, is a flow control device that can alter the direction or velocity of a jet both spatially and temporally. The fuel injection device based on a fluid oscillator significantly enhances atomization and spatial dispersion performance compared to a direct-spray nozzle. However, when used in high heat load afterburners with aviation kerosene as the working medium, oxidative coking issues may arise. To address this, it is recommended to use premixed rich fuel-vapor as the working fluid in order to reduce the residence time of fuel in the oscillator. This study investigates the flow rate and frequency variation of ideal air (simulated gas phase fuel) as it moves through a double feedback channel fluid oscillator with varying thicknesses and outlet throat widths. Experimental and numerical simulation methods are employed. And the influence mechanism is analyzed through an examination of the flow field structure within the cavity of the fluid oscillator. The results indicate that increasing the thickness of the fluid oscillator leads to a higher outlet tangential velocity and deflection angle, while simultaneously decreasing the oscillation frequency. Conversely, widening the fluid oscillator throat results in a decrease in tangential velocity, deflection angle, and oscillation frequency. The performance of the fluid oscillator reaches a critical threshold when the outlet throat is square. As thickness increases, the rate of decrease in oscillation frequency and the rate of increase in tangential velocity both slow down. Furthermore, the maximum deflection angle of the airflow at the oscillator outlet reaches a critical value at a thickness of 3.375 mm, beyond which the trend of increasing deflection angle also slows. When the thickness of the oscillator is less than 3.375 mm, mass flow is the predominant driving factor for airflow deflection in the mixing chamber. In contrast, when the thickness is greater than or equal to 3.375 mm, pressure becomes the primary driving factor for this deflection.
期刊介绍:
The European Journal of Mechanics - B/Fluids publishes papers in all fields of fluid mechanics. Although investigations in well-established areas are within the scope of the journal, recent developments and innovative ideas are particularly welcome. Theoretical, computational and experimental papers are equally welcome. Mathematical methods, be they deterministic or stochastic, analytical or numerical, will be accepted provided they serve to clarify some identifiable problems in fluid mechanics, and provided the significance of results is explained. Similarly, experimental papers must add physical insight in to the understanding of fluid mechanics.