Sustained release of heparin from PLLA micropartricles for tissue engineering applications

IF 5 2区 材料科学 Q1 MATERIALS SCIENCE, CHARACTERIZATION & TESTING Polymer Testing Pub Date : 2024-11-01 DOI:10.1016/j.polymertesting.2024.108628
Mojdeh Rajabi , Iman Shabani , Seyed Hossein Ahmadi Tafti , Azadeh Shabani
{"title":"Sustained release of heparin from PLLA micropartricles for tissue engineering applications","authors":"Mojdeh Rajabi ,&nbsp;Iman Shabani ,&nbsp;Seyed Hossein Ahmadi Tafti ,&nbsp;Azadeh Shabani","doi":"10.1016/j.polymertesting.2024.108628","DOIUrl":null,"url":null,"abstract":"<div><div>Heparin holds promise for cardiac tissue engineering, but challenges such as hematoma or bleeding and accumulation in tissue caused by excessive release, and short half-life persist. The present study aimed to introduce a reliable mechanism for the prolonged heparin release from a biocompatible polymer carrier. The designed system must ensure that heparin retains its bioactivity over time while preventing premature release. Heparin was encapsulated within poly (L-lactic acid) microparticles using the double emulsion method, with polyvinyl alcohol employed as the stabilizer. The encapsulation efficiency of heparin in the microparticles was calculated as 25.56 %. The functionality of the design was evaluated using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectroscopy. Drug release and microparticle degradation studies were conducted alongside cell viability tests. The particle sizes ranged from 5 to 10 ± 2.53 μm, with evidence suggesting that heparin promotes the smaller particle formation. The system demonstrated a consistent drug release profile over six weeks with a release rate of 54 % by week two and 97.65 % by week six. The degradation of heparin-loaded microparticles reached less than 50 % by week six, and the loading of heparin did not significantly affect the degradation behavior of the PLLA microparticles in PBS. Furthermore, heparin concentrations between 200 and 400 μg/ml enhanced the viability of Placenta-derived Mesenchymal Stem Cells and H9c2. These findings suggest that the system could be considered as an effective vehicle for sustained heparin delivery across a spectrum of biological applications, particularly in cardiac tissue engineering.</div></div>","PeriodicalId":20628,"journal":{"name":"Polymer Testing","volume":"140 ","pages":"Article 108628"},"PeriodicalIF":5.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymer Testing","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142941824003052","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

Abstract

Heparin holds promise for cardiac tissue engineering, but challenges such as hematoma or bleeding and accumulation in tissue caused by excessive release, and short half-life persist. The present study aimed to introduce a reliable mechanism for the prolonged heparin release from a biocompatible polymer carrier. The designed system must ensure that heparin retains its bioactivity over time while preventing premature release. Heparin was encapsulated within poly (L-lactic acid) microparticles using the double emulsion method, with polyvinyl alcohol employed as the stabilizer. The encapsulation efficiency of heparin in the microparticles was calculated as 25.56 %. The functionality of the design was evaluated using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-ray Spectroscopy. Drug release and microparticle degradation studies were conducted alongside cell viability tests. The particle sizes ranged from 5 to 10 ± 2.53 μm, with evidence suggesting that heparin promotes the smaller particle formation. The system demonstrated a consistent drug release profile over six weeks with a release rate of 54 % by week two and 97.65 % by week six. The degradation of heparin-loaded microparticles reached less than 50 % by week six, and the loading of heparin did not significantly affect the degradation behavior of the PLLA microparticles in PBS. Furthermore, heparin concentrations between 200 and 400 μg/ml enhanced the viability of Placenta-derived Mesenchymal Stem Cells and H9c2. These findings suggest that the system could be considered as an effective vehicle for sustained heparin delivery across a spectrum of biological applications, particularly in cardiac tissue engineering.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于组织工程的聚乳酸微囊持续释放肝素
肝素在心脏组织工程中大有可为,但肝素过度释放导致的血肿或出血、组织内蓄积以及半衰期短等问题依然存在。本研究旨在引入一种可靠的机制,以延长肝素从生物相容性聚合物载体中的释放时间。所设计的系统必须确保肝素长期保持其生物活性,同时防止过早释放。采用双乳液法将肝素封装在聚(L-乳酸)微粒中,并使用聚乙烯醇作为稳定剂。经计算,肝素在微粒中的封装效率为 25.56%。使用衰减全反射傅立叶变换红外光谱仪、扫描电子显微镜和能量色散 X 射线光谱仪对设计的功能性进行了评估。在进行细胞活力测试的同时,还进行了药物释放和微粒降解研究。微粒的大小从 5 微米到 10 ± 2.53 微米不等,有证据表明肝素促进了较小微粒的形成。该系统在六周内表现出稳定的药物释放曲线,第二周的释放率为 54%,第六周为 97.65%。到第六周时,肝素负载微颗粒的降解率低于 50%,肝素负载对聚乳酸微颗粒在 PBS 中的降解行为没有显著影响。此外,肝素浓度在 200 至 400 μg/ml 之间时,可提高胎盘间充质干细胞和 H9c2 的存活率。这些研究结果表明,该系统可作为持续肝素递送的有效载体,应用于各种生物领域,尤其是心脏组织工程领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Polymer Testing
Polymer Testing 工程技术-材料科学:表征与测试
CiteScore
10.70
自引率
5.90%
发文量
328
审稿时长
44 days
期刊介绍: Polymer Testing focuses on the testing, analysis and characterization of polymer materials, including both synthetic and natural or biobased polymers. Novel testing methods and the testing of novel polymeric materials in bulk, solution and dispersion is covered. In addition, we welcome the submission of the testing of polymeric materials for a wide range of applications and industrial products as well as nanoscale characterization. The scope includes but is not limited to the following main topics: Novel testing methods and Chemical analysis • mechanical, thermal, electrical, chemical, imaging, spectroscopy, scattering and rheology Physical properties and behaviour of novel polymer systems • nanoscale properties, morphology, transport properties Degradation and recycling of polymeric materials when combined with novel testing or characterization methods • degradation, biodegradation, ageing and fire retardancy Modelling and Simulation work will be only considered when it is linked to new or previously published experimental results.
期刊最新文献
Microdroplet pull-out testing: Significance of fiber fracture results Fabrication of advanced polyphenylene sulfide composites by in-situ grafting of sulfide silane and PCPA on glass fibers Classification of black plastic types by hyperspectral imaging based on long-wave infrared emission spectroscopy Investigation of the degradation behaviour of poly-L-lactic acid braided stents under real-time and accelerated conditions Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1