How speech in acoustically different offices influences a working person? – Experiments in two countries

IF 7.1 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Building and Environment Pub Date : 2024-11-02 DOI:10.1016/j.buildenv.2024.112262
Jenni Radun , Jukka Keränen , Reijo Alakoivu , Isabel S. Schiller , Sabine J. Schlittmeier , Valtteri Hongisto
{"title":"How speech in acoustically different offices influences a working person? – Experiments in two countries","authors":"Jenni Radun ,&nbsp;Jukka Keränen ,&nbsp;Reijo Alakoivu ,&nbsp;Isabel S. Schiller ,&nbsp;Sabine J. Schlittmeier ,&nbsp;Valtteri Hongisto","doi":"10.1016/j.buildenv.2024.112262","DOIUrl":null,"url":null,"abstract":"<div><div>Working during task-irrelevant speech influences workers. Adequate room acoustic design can reduce the negative effects in open-plan offices, but harmonized target values do not exist. Our purpose was to examine the effects of room acoustic design levels on a working person during the exposure to task-irrelevant speech. The Finnish room acoustic regulation was chosen as a reference, as it is one of the strictest worldwide. Three room acoustic conditions were examined: regulation violated (Reg-) (Speech Transmission Index, STI=0.71), regulation fulfilled (Reg0) (STI=0.37), and regulation surpassed (Reg+) (STI=0.16). To examine the generalizability of the results, a similar experiment was performed in two countries (two languages and laboratories): Finland and Germany (FinGer study, <em>N</em> = 98). Experience was measured with questionnaires, performance with visual and auditory serial recall tasks, and physiological stress with heart rate variability. Results did not depend on the country, suggesting that our findings could be similar also in other countries. Speech annoyance and perceived concentration difficulty differed in each condition. With other experience measures, only Reg+ improved experience compared to the two other conditions. Visual serial recall performance was more accurate and faster in Reg+ than in Reg-. Accuracy was also improved in Reg0 compared to Reg-. The physiological stress levels did not depend on the condition. Our study shows that Reg0 was better than Reg- with respect to experience and performance but experience was further improved from Reg0 to Reg+. Therefore, it is beneficial to design room acoustics better than the Finnish regulation to maximize work performance and experience.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"267 ","pages":"Article 112262"},"PeriodicalIF":7.1000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132324011041","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Working during task-irrelevant speech influences workers. Adequate room acoustic design can reduce the negative effects in open-plan offices, but harmonized target values do not exist. Our purpose was to examine the effects of room acoustic design levels on a working person during the exposure to task-irrelevant speech. The Finnish room acoustic regulation was chosen as a reference, as it is one of the strictest worldwide. Three room acoustic conditions were examined: regulation violated (Reg-) (Speech Transmission Index, STI=0.71), regulation fulfilled (Reg0) (STI=0.37), and regulation surpassed (Reg+) (STI=0.16). To examine the generalizability of the results, a similar experiment was performed in two countries (two languages and laboratories): Finland and Germany (FinGer study, N = 98). Experience was measured with questionnaires, performance with visual and auditory serial recall tasks, and physiological stress with heart rate variability. Results did not depend on the country, suggesting that our findings could be similar also in other countries. Speech annoyance and perceived concentration difficulty differed in each condition. With other experience measures, only Reg+ improved experience compared to the two other conditions. Visual serial recall performance was more accurate and faster in Reg+ than in Reg-. Accuracy was also improved in Reg0 compared to Reg-. The physiological stress levels did not depend on the condition. Our study shows that Reg0 was better than Reg- with respect to experience and performance but experience was further improved from Reg0 to Reg+. Therefore, it is beneficial to design room acoustics better than the Finnish regulation to maximize work performance and experience.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同声学环境中的讲话如何影响上班族?- 在两个国家进行的实验
在与任务无关的讲话中工作会影响工人。适当的室内声学设计可以减少开放式办公室的负面影响,但目前还没有统一的目标值。我们的目的是研究室内声学设计水平对工作时暴露于与任务无关的讲话中的工作人员的影响。我们选择了芬兰的室内声学法规作为参考,因为它是世界上最严格的法规之一。研究了三种室内声学条件:违反规定(Reg-)(语音传输指数,STI=0.71)、符合规定(Reg0)(STI=0.37)和超过规定(Reg+)(STI=0.16)。为了检验结果的普遍性,我们在两个国家(两种语言和实验室)进行了类似的实验:芬兰和德国(FinGer 研究,N = 98)。实验采用问卷调查法测量体验,采用视觉和听觉序列回忆任务测量表现,采用心率变异性测量生理压力。结果与国家无关,这表明我们的研究结果在其他国家也可能类似。在每种情况下,语言烦恼和感知到的注意力集中难度都有所不同。在其他体验测量中,只有 Reg+ 比其他两种条件下的体验更好。与 Reg- 相比,Reg+ 的视觉连续回忆表现更准确、更快速。与 Reg- 相比,Reg0 的准确性也有所提高。生理压力水平与条件无关。我们的研究表明,就经验和成绩而言,Reg0 比 Reg- 更好,但从 Reg0 到 Reg+,经验得到了进一步改善。因此,设计出比芬兰规定更好的室内声学效果,有利于最大限度地提高工作绩效和体验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
期刊最新文献
Editorial Board Validation of large eddy simulations in urban wind studies using a new overall area metric Assessment of dust endotoxins, airborne bacteria, and PM2.5 at old-age nursing homes and children's daycare centers in the Seoul metropolitan area, South Korea Contextual evaluation of the impact of dynamic urban window view content on view satisfaction Challenges and future directions in evaporative cooling: Balancing sustainable cooling with microbial safety
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1