Ruoxun Zi, Batool Abbas, Bili Wang, Jerzy Walczyk, Ryan Brown, Catherine Petchprapa, James Fishbaugh, Guido Gerig, Kai Tobias Block, Riccardo Lattanzi
{"title":"High-resolution volumetric dynamic magnetic resonance imaging of the wrist using an 8-channel flexible receive coil.","authors":"Ruoxun Zi, Batool Abbas, Bili Wang, Jerzy Walczyk, Ryan Brown, Catherine Petchprapa, James Fishbaugh, Guido Gerig, Kai Tobias Block, Riccardo Lattanzi","doi":"10.1007/s00256-024-04829-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Real-time imaging is useful for the evaluation of wrist instability. However, currently available real-time magnetic resonance imaging (MRI) methods are limited due to their 2D nature or provide insufficient temporal resolution and image quality for quantitative kinematic analysis. This work introduces a novel approach for volumetric dynamic MRI of the wrist joint during active motion and demonstrates the feasibility of tracking carpal bone motion.</p><p><strong>Materials and methods: </strong>A flexible 8-element 3 T wrist receive coil and 3D-printed support platform for guiding motion were designed for dynamic wrist imaging. 2D real-time images were acquired using a fat-saturated FLASH sequence with radial sampling and reconstructed with the GRASP algorithm. Corresponding volumetric dynamic wrist images were obtained by assembling 2D real-time images into 3D snapshots using autodetected MRI-visible markers for slice alignment. The proposed method was demonstrated for radial-ulnar deviation on five healthy volunteers.</p><p><strong>Results: </strong>The flexible wrist coil provided high SNR while allowing a wide range of wrist movements. 2D real-time wrist images were acquired with a temporal resolution of 48 ms/frame with negligible streaking artifacts. Carpal bones and metacarpal bones were properly aligned in the assembled dynamic volumes for all five subjects. The excellent bone-to-tissue contrast enabled accurate segmentation of the individual carpal bones on the assembled dynamic volumes.</p><p><strong>Conclusion: </strong>This work introduces a novel wrist coil and demonstrates that real-time volumetric dynamic examination of the moving wrist is feasible. The achieved image quality and high temporal resolution could enable automatic segmentation of carpal bones and quantitative kinematic assessment for evaluating wrist instability.</p>","PeriodicalId":21783,"journal":{"name":"Skeletal Radiology","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Skeletal Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00256-024-04829-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Real-time imaging is useful for the evaluation of wrist instability. However, currently available real-time magnetic resonance imaging (MRI) methods are limited due to their 2D nature or provide insufficient temporal resolution and image quality for quantitative kinematic analysis. This work introduces a novel approach for volumetric dynamic MRI of the wrist joint during active motion and demonstrates the feasibility of tracking carpal bone motion.
Materials and methods: A flexible 8-element 3 T wrist receive coil and 3D-printed support platform for guiding motion were designed for dynamic wrist imaging. 2D real-time images were acquired using a fat-saturated FLASH sequence with radial sampling and reconstructed with the GRASP algorithm. Corresponding volumetric dynamic wrist images were obtained by assembling 2D real-time images into 3D snapshots using autodetected MRI-visible markers for slice alignment. The proposed method was demonstrated for radial-ulnar deviation on five healthy volunteers.
Results: The flexible wrist coil provided high SNR while allowing a wide range of wrist movements. 2D real-time wrist images were acquired with a temporal resolution of 48 ms/frame with negligible streaking artifacts. Carpal bones and metacarpal bones were properly aligned in the assembled dynamic volumes for all five subjects. The excellent bone-to-tissue contrast enabled accurate segmentation of the individual carpal bones on the assembled dynamic volumes.
Conclusion: This work introduces a novel wrist coil and demonstrates that real-time volumetric dynamic examination of the moving wrist is feasible. The achieved image quality and high temporal resolution could enable automatic segmentation of carpal bones and quantitative kinematic assessment for evaluating wrist instability.
期刊介绍:
Skeletal Radiology provides a forum for the dissemination of current knowledge and information dealing with disorders of the musculoskeletal system including the spine. While emphasizing the radiological aspects of the many varied skeletal abnormalities, the journal also adopts an interdisciplinary approach, reflecting the membership of the International Skeletal Society. Thus, the anatomical, pathological, physiological, clinical, metabolic and epidemiological aspects of the many entities affecting the skeleton receive appropriate consideration.