{"title":"Split-type photoelectrochemical immunosensor integrating ZIF-8@Ag NPs-assisted cation-exchange and Fe2O3/ZnIn2S4 nanoarrays for detection of carbohydrate antigen 72–4","authors":"Shanghua Liu, Feng Jiang, Yueyuan Li, Huijuan Lin, Qing Liu, Shujun Wang, Qin Wei, Yueyun Li","doi":"10.1016/j.snb.2024.136967","DOIUrl":null,"url":null,"abstract":"The sensitivity, accuracy, and stability of a photoelectrochemical (PEC) immunosensor directly depends on the type of sensing substrate and the efficiency of the recognition model in immobilizing biological elements within multilayer assemblies. In this work, a split-type PEC immunosensor integrating Ag nanoparticles-modified ZIF-8 (ZIF-8@Ag NPs)-assisted cation-exchange and Fe<sub>2</sub>O<sub>3</sub>/ZnIn<sub>2</sub>S<sub>4</sub> nanoarrays (NAs) as well-ordered sensing substrate and photoactive material was developed for the detection of carbohydrate antigen 72–4 (CA72–4), a novel gastric cancer target. With effectively harvesting visible light, the stability signal output and the rapid carrier separation, the Z-Scheme Fe<sub>2</sub>O<sub>3</sub>/ZnIn<sub>2</sub>S<sub>4</sub> NAs heterojunction was successfully grown on an indium tin oxide (ITO) electrode as the signal converter and sensing substrate via two-step solvothermal method. The ZIF-8@Ag NPs were employed as the signal label to release silver ions (Ag<sup>+</sup>), relying on the acidolysis in the 96-well plate. The released Ag<sup>+</sup> initiated a cation-exchange (CE) reaction with the Fe<sub>2</sub>O<sub>3</sub>/ZnIn<sub>2</sub>S<sub>4</sub> NAs, forming Fe<sub>2</sub>O<sub>3</sub>/ZnIn<sub>2</sub>S<sub>4</sub>/Ag<sub>2</sub>S ternary complexes with higher photocurrent density. This resulted in a positive correlation trend between CA72–4 concentration (0.01 U/mL to 100 U/mL), and improved the recognition sensitivity of the sensor to trace target, with the limit of detection is 0.0032 U/mL. This work represents an important advancement in overcoming the limitations of multilayer assembly in constructing immunosensors, providing a valuable reference for trace detection of low-abundance disease-related biomarkers.","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"250 1","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.snb.2024.136967","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The sensitivity, accuracy, and stability of a photoelectrochemical (PEC) immunosensor directly depends on the type of sensing substrate and the efficiency of the recognition model in immobilizing biological elements within multilayer assemblies. In this work, a split-type PEC immunosensor integrating Ag nanoparticles-modified ZIF-8 (ZIF-8@Ag NPs)-assisted cation-exchange and Fe2O3/ZnIn2S4 nanoarrays (NAs) as well-ordered sensing substrate and photoactive material was developed for the detection of carbohydrate antigen 72–4 (CA72–4), a novel gastric cancer target. With effectively harvesting visible light, the stability signal output and the rapid carrier separation, the Z-Scheme Fe2O3/ZnIn2S4 NAs heterojunction was successfully grown on an indium tin oxide (ITO) electrode as the signal converter and sensing substrate via two-step solvothermal method. The ZIF-8@Ag NPs were employed as the signal label to release silver ions (Ag+), relying on the acidolysis in the 96-well plate. The released Ag+ initiated a cation-exchange (CE) reaction with the Fe2O3/ZnIn2S4 NAs, forming Fe2O3/ZnIn2S4/Ag2S ternary complexes with higher photocurrent density. This resulted in a positive correlation trend between CA72–4 concentration (0.01 U/mL to 100 U/mL), and improved the recognition sensitivity of the sensor to trace target, with the limit of detection is 0.0032 U/mL. This work represents an important advancement in overcoming the limitations of multilayer assembly in constructing immunosensors, providing a valuable reference for trace detection of low-abundance disease-related biomarkers.
期刊介绍:
Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.