Biosensor-Based Microfluidic Platforms for Rapid Clinical Detection of Pathogenic Bacteria

IF 18.5 1区 材料科学 Q1 CHEMISTRY, MULTIDISCIPLINARY Advanced Functional Materials Pub Date : 2024-11-20 DOI:10.1002/adfm.202411484
Ying Hou, Zhen Liu, Haina Huang, Chengming Lou, Zhiwei Sun, Xiaoyan Liu, Jinbo Pang, Shenguang Ge, Zenan Wang, Weijia Zhou, Hong Liu
{"title":"Biosensor-Based Microfluidic Platforms for Rapid Clinical Detection of Pathogenic Bacteria","authors":"Ying Hou, Zhen Liu, Haina Huang, Chengming Lou, Zhiwei Sun, Xiaoyan Liu, Jinbo Pang, Shenguang Ge, Zenan Wang, Weijia Zhou, Hong Liu","doi":"10.1002/adfm.202411484","DOIUrl":null,"url":null,"abstract":"Pathogenic bacteria are commonly found in food, water, and soil, posing significant public health challenges globally. Therefore, early, rapid, and highly sensitive strategies for monitoring the bacterial proliferation are crucial for ensuring public health, medical diagnosis, and food safety. Compared to traditional techniques, microfluidic platforms provide powerful detective tools characterized by high integration, high throughput, ease of operation, low reagent consumption, and high sensitivity. Driven by substantial commercial demand, research and development in microfluidic-based rapid detection methods and technologies has progressed significantly derived by the interdisciplinary integration of multiple disciplines. In this review, progress in clinical detection of pathogenic bacteria with microfluidic biosensors, including microfluidic devices for point-of-care (POC) testing, is summarized. Strategies for pathogenic bacteria detection, containing their advantages and disadvantages are discussed in detail. Advanced platforms for capturing and detecting pathogenic bacteria, such as microchannels, microarrays, digital microfluidics (DMF) and paper-based platforms, are highlighted. The accomplishments and shortcomings of these microfluidic devices are also summarized. Additionally, case studies of biosensor‑based microfluidic devices used for detecting diseases caused by bacterial imbalances are listed. Finally, possible research perspectives for further development in highly effective biosensor‑based microfluidics for clinical detection of pathogenic bacteria are proposed.","PeriodicalId":112,"journal":{"name":"Advanced Functional Materials","volume":"60 1","pages":""},"PeriodicalIF":18.5000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Functional Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1002/adfm.202411484","RegionNum":1,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Pathogenic bacteria are commonly found in food, water, and soil, posing significant public health challenges globally. Therefore, early, rapid, and highly sensitive strategies for monitoring the bacterial proliferation are crucial for ensuring public health, medical diagnosis, and food safety. Compared to traditional techniques, microfluidic platforms provide powerful detective tools characterized by high integration, high throughput, ease of operation, low reagent consumption, and high sensitivity. Driven by substantial commercial demand, research and development in microfluidic-based rapid detection methods and technologies has progressed significantly derived by the interdisciplinary integration of multiple disciplines. In this review, progress in clinical detection of pathogenic bacteria with microfluidic biosensors, including microfluidic devices for point-of-care (POC) testing, is summarized. Strategies for pathogenic bacteria detection, containing their advantages and disadvantages are discussed in detail. Advanced platforms for capturing and detecting pathogenic bacteria, such as microchannels, microarrays, digital microfluidics (DMF) and paper-based platforms, are highlighted. The accomplishments and shortcomings of these microfluidic devices are also summarized. Additionally, case studies of biosensor‑based microfluidic devices used for detecting diseases caused by bacterial imbalances are listed. Finally, possible research perspectives for further development in highly effective biosensor‑based microfluidics for clinical detection of pathogenic bacteria are proposed.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于生物传感器的微流控平台用于病原菌的快速临床检测
致病细菌通常存在于食物、水和土壤中,对全球公共卫生构成重大挑战。因此,早期、快速和高灵敏度的细菌扩散监测策略对于确保公共卫生、医疗诊断和食品安全至关重要。与传统技术相比,微流控平台提供了强大的检测工具,具有高集成度、高通量、易操作、低试剂消耗和高灵敏度等特点。在大量商业需求的推动下,基于微流控的快速检测方法和技术的研究与开发在多学科的交叉融合下取得了显著进展。本综述总结了利用微流体生物传感器(包括用于床旁检测(POC)的微流体设备)对致病菌进行临床检测的进展。详细讨论了病原菌检测策略及其优缺点。重点介绍了捕获和检测病原菌的先进平台,如微通道、微阵列、数字微流控(DMF)和纸质平台。还总结了这些微流控设备的成就和不足。此外,还列举了用于检测细菌失衡引起的疾病的基于生物传感器的微流控装置的案例研究。最后,提出了进一步开发基于生物传感器的高效微流控技术用于临床病原菌检测的可能研究前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advanced Functional Materials
Advanced Functional Materials 工程技术-材料科学:综合
CiteScore
29.50
自引率
4.20%
发文量
2086
审稿时长
2.1 months
期刊介绍: Firmly established as a top-tier materials science journal, Advanced Functional Materials reports breakthrough research in all aspects of materials science, including nanotechnology, chemistry, physics, and biology every week. Advanced Functional Materials is known for its rapid and fair peer review, quality content, and high impact, making it the first choice of the international materials science community.
期刊最新文献
Enhanced Mechanical-Magnetic Coupling and Bioinspired Structural Design of Magnetorheological Elastomers Band Structure and Spin-State-Induced Electronic Configuration Regulation for Efficient Sulfur Redox Reaction The Out-of-Plane C─S Bonds Boosting Reversible Redox in Copper Sulfide Cathodes for Ultradurable Magnesium Battery 12.86% Efficient Cu2ZnSn(S,Se)4 Thin Film Solar Cells via Inkjet Printing with 2-Methoxyethanol-Based Air-Stable Precursor Ink Atomically Dispersed Scandium in Cuprous Oxide Weakens *CO Adsorption to Boost Carbon Dioxide Electroreduction Toward C2 Products
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1