Pin Zhong Chan, Eric Jin, Miia Jansson, Han Shi Jocelyn Chew
{"title":"AI-Based Noninvasive Blood Glucose Monitoring: Scoping Review.","authors":"Pin Zhong Chan, Eric Jin, Miia Jansson, Han Shi Jocelyn Chew","doi":"10.2196/58892","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Current blood glucose monitoring (BGM) methods are often invasive and require repetitive pricking of a finger to obtain blood samples, predisposing individuals to pain, discomfort, and infection. Noninvasive blood glucose monitoring (NIBGM) is ideal for minimizing discomfort, reducing the risk of infection, and increasing convenience.</p><p><strong>Objective: </strong>This review aimed to map the use cases of artificial intelligence (AI) in NIBGM.</p><p><strong>Methods: </strong>A systematic scoping review was conducted according to the Arksey O'Malley five-step framework. Eight electronic databases (CINAHL, Embase, PubMed, Web of Science, Scopus, The Cochrane-Central Library, ACM Digital Library, and IEEE Xplore) were searched from inception until February 8, 2023. Study selection was conducted by 2 independent reviewers, descriptive analysis was conducted, and findings were presented narratively. Study characteristics (author, country, type of publication, study design, population characteristics, mean age, types of noninvasive techniques used, and application, as well as characteristics of the BGM systems) were extracted independently and cross-checked by 2 investigators. Methodological quality appraisal was conducted using the Checklist for assessment of medical AI.</p><p><strong>Results: </strong>A total of 33 papers were included, representing studies from Asia, the United States, Europe, the Middle East, and Africa published between 2005 and 2023. Most studies used optical techniques (n=19, 58%) to estimate blood glucose levels (n=27, 82%). Others used electrochemical sensors (n=4), imaging (n=2), mixed techniques (n=2), and tissue impedance (n=1). Accuracy ranged from 35.56% to 94.23% and Clarke error grid (A+B) ranged from 86.91% to 100%. The most popular machine learning algorithm used was random forest (n=10) and the most popular deep learning model was the artificial neural network (n=6). The mean overall checklist for assessment of medical AI score on the included papers was 33.5 (SD 3.09), suggesting an average of medium quality. The studies reviewed demonstrate that some AI techniques can accurately predict glucose levels from noninvasive sources while enhancing comfort and ease of use for patients. However, the overall range of accuracy was wide due to the heterogeneity of models and input data.</p><p><strong>Conclusions: </strong>Efforts are needed to standardize and regulate the use of AI technologies in BGM, as well as develop consensus guidelines and protocols to ensure the quality and safety of AI-assisted monitoring systems. The use of AI for NIBGM is a promising area of research that has the potential to revolutionize diabetes management.</p>","PeriodicalId":16337,"journal":{"name":"Journal of Medical Internet Research","volume":"26 ","pages":"e58892"},"PeriodicalIF":5.8000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Internet Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2196/58892","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Current blood glucose monitoring (BGM) methods are often invasive and require repetitive pricking of a finger to obtain blood samples, predisposing individuals to pain, discomfort, and infection. Noninvasive blood glucose monitoring (NIBGM) is ideal for minimizing discomfort, reducing the risk of infection, and increasing convenience.
Objective: This review aimed to map the use cases of artificial intelligence (AI) in NIBGM.
Methods: A systematic scoping review was conducted according to the Arksey O'Malley five-step framework. Eight electronic databases (CINAHL, Embase, PubMed, Web of Science, Scopus, The Cochrane-Central Library, ACM Digital Library, and IEEE Xplore) were searched from inception until February 8, 2023. Study selection was conducted by 2 independent reviewers, descriptive analysis was conducted, and findings were presented narratively. Study characteristics (author, country, type of publication, study design, population characteristics, mean age, types of noninvasive techniques used, and application, as well as characteristics of the BGM systems) were extracted independently and cross-checked by 2 investigators. Methodological quality appraisal was conducted using the Checklist for assessment of medical AI.
Results: A total of 33 papers were included, representing studies from Asia, the United States, Europe, the Middle East, and Africa published between 2005 and 2023. Most studies used optical techniques (n=19, 58%) to estimate blood glucose levels (n=27, 82%). Others used electrochemical sensors (n=4), imaging (n=2), mixed techniques (n=2), and tissue impedance (n=1). Accuracy ranged from 35.56% to 94.23% and Clarke error grid (A+B) ranged from 86.91% to 100%. The most popular machine learning algorithm used was random forest (n=10) and the most popular deep learning model was the artificial neural network (n=6). The mean overall checklist for assessment of medical AI score on the included papers was 33.5 (SD 3.09), suggesting an average of medium quality. The studies reviewed demonstrate that some AI techniques can accurately predict glucose levels from noninvasive sources while enhancing comfort and ease of use for patients. However, the overall range of accuracy was wide due to the heterogeneity of models and input data.
Conclusions: Efforts are needed to standardize and regulate the use of AI technologies in BGM, as well as develop consensus guidelines and protocols to ensure the quality and safety of AI-assisted monitoring systems. The use of AI for NIBGM is a promising area of research that has the potential to revolutionize diabetes management.
期刊介绍:
The Journal of Medical Internet Research (JMIR) is a highly respected publication in the field of health informatics and health services. With a founding date in 1999, JMIR has been a pioneer in the field for over two decades.
As a leader in the industry, the journal focuses on digital health, data science, health informatics, and emerging technologies for health, medicine, and biomedical research. It is recognized as a top publication in these disciplines, ranking in the first quartile (Q1) by Impact Factor.
Notably, JMIR holds the prestigious position of being ranked #1 on Google Scholar within the "Medical Informatics" discipline.