Evaluation of the fabrication trueness and internal fit of additively manufactured two-piece zirconia abutments with different build orientations compared to subtractively manufactured abutments
Münir Demirel , Almira Ada Diken Türksayar , Mustafa Borga Donmez , Martin Schimmel , Burak Yilmaz
{"title":"Evaluation of the fabrication trueness and internal fit of additively manufactured two-piece zirconia abutments with different build orientations compared to subtractively manufactured abutments","authors":"Münir Demirel , Almira Ada Diken Türksayar , Mustafa Borga Donmez , Martin Schimmel , Burak Yilmaz","doi":"10.1016/j.jdent.2024.105470","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate the effect of build orientation on the fabrication trueness and fit of additively manufactured 2-piece zirconia abutments when compared with those manufactured subtractively in 3 mol% and 4 mol% yttria-stabilized zirconia (3Y-TZP and 4Y-TZP).</div></div><div><h3>Methods</h3><div>A titanium-base (Ti-base) abutment was digitized with a scan body and an industrial scanner to design a 2-piece zirconia abutment with a 50 µm cement gap. This design was used to manufacture zirconia abutments additively in different orientations (0-degree, AM-0; 15-degree, AM-15; 30-degree, AM-30; 45-degree, AM-45; 180-degree, AM-180) and subtractively from 3Y-TZP and 4Y-TZP (SM-3 and SM-4) (n=5). An intraoral scanner was used to digitize all abutments, when they were seated on the Ti-base, and only the Ti-base. Abutments’ trueness (overall, external, intaglio, and marginal) was analyzed with the root mean square (RMS) method, and their fit was assessed with the triple-scan protocol. Data were analyzed with 1-way analysis of variance and Tamhane's T2 tests (α = 0.05).</div></div><div><h3>Results</h3><div>SM-3 abutments had the lowest overall and external RMS (<em>P</em> ≤ 0.023). SM-3 and SM-4 abutments mostly had lower intaglio and AM-0 abutments mostly had lower gingival RMS (<em>P ≤</em> 0<em>.</em>013). Except for AM-0 and SM-3 (<em>P ≥</em> 0.930), SM-4 abutments had the lowest average gaps (<em>P ≤</em> 0.041).</div></div><div><h3>Conclusions</h3><div>SM-3 abutments mostly had higher fabrication trueness, while AM-0 abutments had trueness similar to or higher than the other additively manufactured abutments. AM-0, SM-3, and SM-4 abutments had similar fit with average gaps lower than 50 µm.</div></div>","PeriodicalId":15585,"journal":{"name":"Journal of dentistry","volume":"153 ","pages":"Article 105470"},"PeriodicalIF":4.8000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300571224006407","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To evaluate the effect of build orientation on the fabrication trueness and fit of additively manufactured 2-piece zirconia abutments when compared with those manufactured subtractively in 3 mol% and 4 mol% yttria-stabilized zirconia (3Y-TZP and 4Y-TZP).
Methods
A titanium-base (Ti-base) abutment was digitized with a scan body and an industrial scanner to design a 2-piece zirconia abutment with a 50 µm cement gap. This design was used to manufacture zirconia abutments additively in different orientations (0-degree, AM-0; 15-degree, AM-15; 30-degree, AM-30; 45-degree, AM-45; 180-degree, AM-180) and subtractively from 3Y-TZP and 4Y-TZP (SM-3 and SM-4) (n=5). An intraoral scanner was used to digitize all abutments, when they were seated on the Ti-base, and only the Ti-base. Abutments’ trueness (overall, external, intaglio, and marginal) was analyzed with the root mean square (RMS) method, and their fit was assessed with the triple-scan protocol. Data were analyzed with 1-way analysis of variance and Tamhane's T2 tests (α = 0.05).
Results
SM-3 abutments had the lowest overall and external RMS (P ≤ 0.023). SM-3 and SM-4 abutments mostly had lower intaglio and AM-0 abutments mostly had lower gingival RMS (P ≤ 0.013). Except for AM-0 and SM-3 (P ≥ 0.930), SM-4 abutments had the lowest average gaps (P ≤ 0.041).
Conclusions
SM-3 abutments mostly had higher fabrication trueness, while AM-0 abutments had trueness similar to or higher than the other additively manufactured abutments. AM-0, SM-3, and SM-4 abutments had similar fit with average gaps lower than 50 µm.
期刊介绍:
The Journal of Dentistry has an open access mirror journal The Journal of Dentistry: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review.
The Journal of Dentistry is the leading international dental journal within the field of Restorative Dentistry. Placing an emphasis on publishing novel and high-quality research papers, the Journal aims to influence the practice of dentistry at clinician, research, industry and policy-maker level on an international basis.
Topics covered include the management of dental disease, periodontology, endodontology, operative dentistry, fixed and removable prosthodontics, dental biomaterials science, long-term clinical trials including epidemiology and oral health, technology transfer of new scientific instrumentation or procedures, as well as clinically relevant oral biology and translational research.
The Journal of Dentistry will publish original scientific research papers including short communications. It is also interested in publishing review articles and leaders in themed areas which will be linked to new scientific research. Conference proceedings are also welcome and expressions of interest should be communicated to the Editor.