{"title":"Magnesium-based bioresorbable flow diverter for intracranial aneurysms: a pilot study of biocompatibility and bioresorption in a rabbit vascular model.","authors":"Ryo Akiyama, Akira Ishii, Natsuhi Sasaki, So Matsukawa, Shinichi Yagi, Hideo Chihara, Hidehisa Nishi, Kiyotaka Iwasaki, Shinichi Sakurai, Yoshihito Kawamura, Yoshiki Arakawa","doi":"10.1136/jnis-2024-022527","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Bioresorbable flow diverters (BRFDs) have the potential to solve several problems associated with conventional permanent flow diverters. We have constructed bare and poly-L-lactic acid (PLLA)-coated magnesium BRFDs (MgBRFDs) using a high-strength corrosion-resistant magnesium alloy. This study aimed to compare bioresorption and biocompatibility between the two types in a rabbit vascular model to determine which is more clinically feasible in humans.</p><p><strong>Methods: </strong>Bare and PLLA-coated MgBRFDs were fabricated by braiding 48 thin magnesium alloy wires. Mechanical testing was conducted. Bare (n=13) and PLLA-coated (n=13) MgBRFDs were implanted into rabbit aortas and harvested 14, 30, and 90 days after implantation. The physical structure of the resolution process was examined using optical coherence tomography (OCT), micro-computed tomography, and scanning electron microscopy (SEM). The biological response of the vascular tissue was examined using SEM and histopathological analysis.</p><p><strong>Results: </strong>The porosity and pore density of the bare MgBRFD were 64% and 16 pores/mm<sup>2</sup>, respectively; corresponding values for the PLLA-coated MgBRFD were 63% and 12 pores/mm<sup>2</sup>, respectively. The OCT attenuation score was significantly higher for the PLLA-coated MgBRFD at all time points (14 days, P=0.01; 30 days, P=0.02; 90 days, P=0.004). OCT, micro-computed tomography, and SEM demonstrated better stent structure preservation with the PLLA-coated MgBRFD. Neointimal thickness did not significantly change over time in either type of MgBRFD (bare, P=0.93; PLLA-coated, P=0.34); however, the number of inflammatory and proliferative cells peaked at 14 days and then decreased.</p><p><strong>Conclusions: </strong>Both bare and PLLA-coated MgBRFDs had excellent biocompatibility. The PLLA-coated MgBRFD has greater clinical feasibility because of its delayed bioresorption.</p>","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":" ","pages":""},"PeriodicalIF":4.5000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2024-022527","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Bioresorbable flow diverters (BRFDs) have the potential to solve several problems associated with conventional permanent flow diverters. We have constructed bare and poly-L-lactic acid (PLLA)-coated magnesium BRFDs (MgBRFDs) using a high-strength corrosion-resistant magnesium alloy. This study aimed to compare bioresorption and biocompatibility between the two types in a rabbit vascular model to determine which is more clinically feasible in humans.

Methods: Bare and PLLA-coated MgBRFDs were fabricated by braiding 48 thin magnesium alloy wires. Mechanical testing was conducted. Bare (n=13) and PLLA-coated (n=13) MgBRFDs were implanted into rabbit aortas and harvested 14, 30, and 90 days after implantation. The physical structure of the resolution process was examined using optical coherence tomography (OCT), micro-computed tomography, and scanning electron microscopy (SEM). The biological response of the vascular tissue was examined using SEM and histopathological analysis.

Results: The porosity and pore density of the bare MgBRFD were 64% and 16 pores/mm2, respectively; corresponding values for the PLLA-coated MgBRFD were 63% and 12 pores/mm2, respectively. The OCT attenuation score was significantly higher for the PLLA-coated MgBRFD at all time points (14 days, P=0.01; 30 days, P=0.02; 90 days, P=0.004). OCT, micro-computed tomography, and SEM demonstrated better stent structure preservation with the PLLA-coated MgBRFD. Neointimal thickness did not significantly change over time in either type of MgBRFD (bare, P=0.93; PLLA-coated, P=0.34); however, the number of inflammatory and proliferative cells peaked at 14 days and then decreased.

Conclusions: Both bare and PLLA-coated MgBRFDs had excellent biocompatibility. The PLLA-coated MgBRFD has greater clinical feasibility because of its delayed bioresorption.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于颅内动脉瘤的镁基生物可吸收血流分流器:在兔子血管模型中进行的生物相容性和生物吸收试验研究。
背景:生物可吸收血流分流器(BRFD)有望解决与传统永久性血流分流器相关的若干问题。我们使用高强度耐腐蚀镁合金建造了裸体和聚左乳酸(PLLA)涂层的镁生物吸收分流器(MgBRFDs)。本研究的目的是在兔子血管模型中比较两种类型的生物吸附性和生物相容性,以确定哪种类型在人类临床上更可行:方法:通过编织 48 根纤细的镁合金丝,制成了裸镁BRFD 和聚乳酸涂层镁BRFD。进行了机械测试。将裸MgBRFD(n=13)和PLLA涂层MgBRFD(n=13)植入兔子主动脉,并在植入后14天、30天和90天进行采样。使用光学相干断层扫描(OCT)、微型计算机断层扫描和扫描电子显微镜(SEM)检查了解析过程的物理结构。利用扫描电子显微镜和组织病理学分析检查了血管组织的生物反应:裸 MgBRFD 的孔隙率和孔密度分别为 64% 和 16 个孔/平方毫米;PLLA 涂层 MgBRFD 的相应值分别为 63% 和 12 个孔/平方毫米。在所有时间点,PLLA 涂层 MgBRFD 的 OCT 衰减评分都明显更高(14 天,P=0.01;30 天,P=0.02;90 天,P=0.004)。OCT、微型计算机断层扫描和扫描电子显微镜显示,PLLA 涂层 MgBRFD 能更好地保留支架结构。两种 MgBRFD 的新内膜厚度均未随时间发生明显变化(裸支架,P=0.93;PLLA 涂层,P=0.34);然而,炎症细胞和增殖细胞的数量在 14 天时达到峰值,随后下降:裸露和PLLA涂层的MgBRFD都具有良好的生物相容性。结论:裸MgBRFD和PLLA涂层MgBRFD都具有良好的生物相容性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.50
自引率
14.60%
发文量
291
审稿时长
4-8 weeks
期刊介绍: The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.
期刊最新文献
Burden of incidental cerebral aneurysms on lifestyle and quality of life: a survey of patients in expectant management (the SPICE Study). Comprehensive evaluation of management strategies and rupture status in partially thrombosed aneurysms: a systematic review and meta-analysis. Correspondence on: 'Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis' by Orscelik et al. Evaluating the effects of recreational drug use on ruptured cerebral arteriovenous malformation presentation and in-hospital outcomes: a national inpatient sample analysis. Introduction of neurointerventional services, including mechanical thrombectomy, to a resource limited setting in Tanzania.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1