A graphene quantum dots based dual-modal fluorometric and visualized detection of copper ions.

Yuping Guo, Qihan Huang, Fengzhou Xu, Zhishan Luo, Yaojin Wei, Zhijun Chen, Zhichao Zeng, Huihui Zhang, Hui Shi
{"title":"A graphene quantum dots based dual-modal fluorometric and visualized detection of copper ions.","authors":"Yuping Guo, Qihan Huang, Fengzhou Xu, Zhishan Luo, Yaojin Wei, Zhijun Chen, Zhichao Zeng, Huihui Zhang, Hui Shi","doi":"10.1016/j.saa.2024.125442","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we present a dual-modal fluorometric and visualized detection method for Cu<sup>2+</sup> ion, leveraging the synergistic properties of graphene quantum dots (GQDs) and Cu<sup>2+</sup> ion catalyzed Fenton-like reaction. The Fenton-like reaction of Cu<sup>2+</sup> ions and ascorbate generates highly reactive hydroxyl radical (·OH), which effectively disrupt the structure of GQDs, leading to fluorescence quenching. Under optimized conditions, the fluorescence quenching degree exhibited a linear correlation with Cu<sup>2+</sup> concentration within the range of 40 to 2000 nM, enabling the detection of Cu<sup>2+</sup> ions as low as 40 nM. Furthermore, we demonstrated the feasibility of semi-quantitative visual detection of Cu<sup>2+</sup> ion concentrations in water using a portable ultraviolet instrument. The method achieved a minimum detectable concentration of Cu<sup>2+</sup> ion as low as 10 μM, surpassing the maximum contaminant level goals of 20.47 μM set by the EPA and the guideline value of 31.47 μM recommended by the WHO. As such, this approach holds promise as a point-of-care testing (POCT) method for Cu<sup>2+</sup> ion detection during copper pollution emergency events in water. Additionally, this method can be adapted for the detection of ascorbic acid. Our findings showcase the potential of this dual-modal detection approach, offering a sensitive, rapid, and efficient means for detecting Cu<sup>2+</sup> ion, thereby contributing to environmental monitoring and public health applications.</p>","PeriodicalId":94213,"journal":{"name":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","volume":"328 ","pages":"125442"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.saa.2024.125442","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we present a dual-modal fluorometric and visualized detection method for Cu2+ ion, leveraging the synergistic properties of graphene quantum dots (GQDs) and Cu2+ ion catalyzed Fenton-like reaction. The Fenton-like reaction of Cu2+ ions and ascorbate generates highly reactive hydroxyl radical (·OH), which effectively disrupt the structure of GQDs, leading to fluorescence quenching. Under optimized conditions, the fluorescence quenching degree exhibited a linear correlation with Cu2+ concentration within the range of 40 to 2000 nM, enabling the detection of Cu2+ ions as low as 40 nM. Furthermore, we demonstrated the feasibility of semi-quantitative visual detection of Cu2+ ion concentrations in water using a portable ultraviolet instrument. The method achieved a minimum detectable concentration of Cu2+ ion as low as 10 μM, surpassing the maximum contaminant level goals of 20.47 μM set by the EPA and the guideline value of 31.47 μM recommended by the WHO. As such, this approach holds promise as a point-of-care testing (POCT) method for Cu2+ ion detection during copper pollution emergency events in water. Additionally, this method can be adapted for the detection of ascorbic acid. Our findings showcase the potential of this dual-modal detection approach, offering a sensitive, rapid, and efficient means for detecting Cu2+ ion, thereby contributing to environmental monitoring and public health applications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于石墨烯量子点的铜离子荧光和可视化双模式检测。
在本研究中,我们利用石墨烯量子点(GQDs)和 Cu2+ 离子催化的 Fenton 类反应的协同特性,提出了一种 Cu2+ 离子的荧光和可视化双模式检测方法。Cu2+ 离子和抗坏血酸的 Fenton 类反应会产生高活性羟基自由基(-OH),从而有效破坏 GQDs 的结构,导致荧光淬灭。在优化条件下,荧光淬灭度在 40 到 2000 nM 范围内与 Cu2+ 浓度呈线性相关,从而实现了对低至 40 nM 的 Cu2+ 离子的检测。此外,我们还证明了利用便携式紫外仪器对水中 Cu2+ 离子浓度进行半定量视觉检测的可行性。该方法实现了低至 10 μM 的 Cu2+ 离子最低可检测浓度,超过了美国环保局设定的 20.47 μM 的最大污染物水平目标和世界卫生组织推荐的 31.47 μM 的指导值。因此,这种方法有望成为在铜污染紧急事件期间检测水中 Cu2+ 离子的护理点检测 (POCT) 方法。此外,这种方法还可用于检测抗坏血酸。我们的研究结果展示了这种双模式检测方法的潜力,它提供了一种灵敏、快速、高效的 Cu2+ 离子检测方法,从而有助于环境监测和公共卫生应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Age estimation of Phormia regina pupae based on ATR-FTIR and chemometrics. Exploring the charge transfer enhancement mechanism in selective SERS detection with Mo1-xWxS2@Ag2S nanosheets. Improving monitoring of dissolved organic matter from the wastewater treatment plant to the receiving environment: A new high-frequency in situ fluorescence sensor capable of analyzing 29 pairs of Ex/Em wavelengths. Theoretical study of excited state dynamics of a ratiometric fluorescent probe for detection of SO2 derivatives. A Dicyanoisophorone-based Fluorescent Turn-on Probe for Rapid Detecting Thiophenol in Aqueous Medium and Living Cell Imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1