Prevent hypoglycaemia when using automated insulin delivery systems in type 1 diabetes requires near normal glycaemic variability

IF 4.6 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes & metabolism Pub Date : 2024-11-22 DOI:10.1016/j.diabet.2024.101589
Louis Monnier , Claude Colette , Eric Renard , Pierre-Yves Benhamou , Safa Aouinti , Nicolas Molinari , David Owens
{"title":"Prevent hypoglycaemia when using automated insulin delivery systems in type 1 diabetes requires near normal glycaemic variability","authors":"Louis Monnier ,&nbsp;Claude Colette ,&nbsp;Eric Renard ,&nbsp;Pierre-Yves Benhamou ,&nbsp;Safa Aouinti ,&nbsp;Nicolas Molinari ,&nbsp;David Owens","doi":"10.1016/j.diabet.2024.101589","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><div>Although newer technologies of insulin delivery in type 1 diabetes have facilitated an improvement in glycaemic control the risk of hypoglycaemia remains a threat. Therefore, it is important to define the thresholds of glycaemic variability below which the risk of hypoglycaemia can be eliminated or at least minimized.</div></div><div><h3>Methods</h3><div>Randomized controlled trials conducted from 2017 to 2023 comparing Sensor-Augmented-Pumps and Augmented Insulin Delivery Systems (<em>n</em> = 16 and 22 studies, respectively) were selected. A weighted linear model of regression was used to compute the relationship between glycaemic variability and times spent below glucose range. The intercepts of regression lines with the abscissa axis (time below range = 0 %) defined the glycaemic variability thresholds.</div></div><div><h3>Results</h3><div>Positive relationships were observed between the 2 metrics. The scatter plots indicated that the times spent below range never reached the value of 0 % and that the glycaemic variability never fell below 28 %. By extrapolating the regression lines, the glycaemic variability at intercepts with time below range &lt; 70 mg/dL of 0 % was 30.1 % with sensor augmented pumps and 18.9 % with automated insulin delivery. For a time below range &lt; 54 mg/dL of 0 % the respective glycaemic variability values were 32.7 % and 19.9 % (with sensor augmented pumps and automated insulin delivery, respectively).</div></div><div><h3>Conclusions</h3><div>Importantly, glycaemic variability targets and ambient hyperglycaemia are interdependent. Users of automated insulin delivery need to reach a glycaemic variability of 18 % to 20 % to minimize or eradicate the risk of hypoglycaemia. Such values are those observed in healthy non-diabetic people.</div></div>","PeriodicalId":11334,"journal":{"name":"Diabetes & metabolism","volume":"51 1","pages":"Article 101589"},"PeriodicalIF":4.6000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes & metabolism","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1262363624000818","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Aim

Although newer technologies of insulin delivery in type 1 diabetes have facilitated an improvement in glycaemic control the risk of hypoglycaemia remains a threat. Therefore, it is important to define the thresholds of glycaemic variability below which the risk of hypoglycaemia can be eliminated or at least minimized.

Methods

Randomized controlled trials conducted from 2017 to 2023 comparing Sensor-Augmented-Pumps and Augmented Insulin Delivery Systems (n = 16 and 22 studies, respectively) were selected. A weighted linear model of regression was used to compute the relationship between glycaemic variability and times spent below glucose range. The intercepts of regression lines with the abscissa axis (time below range = 0 %) defined the glycaemic variability thresholds.

Results

Positive relationships were observed between the 2 metrics. The scatter plots indicated that the times spent below range never reached the value of 0 % and that the glycaemic variability never fell below 28 %. By extrapolating the regression lines, the glycaemic variability at intercepts with time below range < 70 mg/dL of 0 % was 30.1 % with sensor augmented pumps and 18.9 % with automated insulin delivery. For a time below range < 54 mg/dL of 0 % the respective glycaemic variability values were 32.7 % and 19.9 % (with sensor augmented pumps and automated insulin delivery, respectively).

Conclusions

Importantly, glycaemic variability targets and ambient hyperglycaemia are interdependent. Users of automated insulin delivery need to reach a glycaemic variability of 18 % to 20 % to minimize or eradicate the risk of hypoglycaemia. Such values are those observed in healthy non-diabetic people.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
1 型糖尿病患者在使用胰岛素自动给药系统时,需要接近正常的血糖变异性才能预防低血糖。
目的:尽管 1 型糖尿病患者使用胰岛素给药的新技术改善了血糖控制,但低血糖风险仍然是一个威胁。因此,必须确定血糖变异性的阈值,低于该阈值时,低血糖风险可以消除或至少降至最低:选取了 2017 年至 2023 年期间进行的随机对照试验,比较了传感器增强泵和增强胰岛素给药系统(分别为 16 项和 22 项研究)。采用加权线性回归模型计算血糖变异性与低于血糖范围时间之间的关系。回归线与横轴的截距(低于血糖范围的时间 = 0%)定义了血糖变异性阈值:结果:观察到这两个指标之间存在正相关关系。散点图显示,低于量程的时间从未达到 0%,血糖变异性从未低于 28%。根据回归线推断,低于量程 70 毫克/分升的时间截距为 0% 时,传感器增强泵的血糖变异率为 30.1%,自动胰岛素输送的血糖变异率为 18.9%。对于低于范围 < 54 mg/dL 0% 的时间,血糖变异值分别为 32.7% 和 19.9%(使用传感器增强泵和自动胰岛素输送):重要的是,血糖变异性目标和环境高血糖是相互依存的。胰岛素自动给药用户需要达到 18% 至 20% 的血糖变化率,才能最大限度地降低或消除低血糖风险。这些数值是在健康的非糖尿病患者身上观察到的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diabetes & metabolism
Diabetes & metabolism 医学-内分泌学与代谢
CiteScore
12.00
自引率
4.20%
发文量
86
审稿时长
13 days
期刊介绍: A high quality scientific journal with an international readership Official publication of the SFD, Diabetes & Metabolism, publishes high-quality papers by leading teams, forming a close link between hospital and research units. Diabetes & Metabolism is published in English language and is indexed in all major databases with its impact factor constantly progressing. Diabetes & Metabolism contains original articles, short reports and comprehensive reviews.
期刊最新文献
Prevent hypoglycaemia when using automated insulin delivery systems in type 1 diabetes requires near normal glycaemic variability Medial arterial calcification of the lower limbs in diabetes: Time for awareness? A short narrative review Association of SGLT2 inhibitors with incident cancer Non-dioxin-like polychlorinated biphenyls (NDL-PCBs) dietary exposure is associated with an increased risk of type 2 diabetes in the European prospective investigation into cancer and nutrition (EPIC) cohort Periodontitis adversely affects lipoprotein subfractions – results from the cohort study SHIP-TREND
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1