Length-band fluorescence-based paper analytical device for detecting dipicolinic acid via ofloxacin complexation with Cu²⁺

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analyst Pub Date : 2024-11-26 DOI:10.1039/d4an01393j
Nguyen Ngoc Nghia, Bui The Huy, Nguyen Huu Hieu, Nguyen Thi Kim Phuong, Yong-Ill Lee
{"title":"Length-band fluorescence-based paper analytical device for detecting dipicolinic acid via ofloxacin complexation with Cu²⁺","authors":"Nguyen Ngoc Nghia, Bui The Huy, Nguyen Huu Hieu, Nguyen Thi Kim Phuong, Yong-Ill Lee","doi":"10.1039/d4an01393j","DOIUrl":null,"url":null,"abstract":"Dipicolinic acid (DPA) is a key biomarker of bacterial spores. In this study, we present a novel distance-based paper analytical device (d-PAD) for the fluorescence sensing of DPA. The detection mechanism relies on the complexation of ofloxacin (OFL) with Cu²⁺ ions, where Cu²⁺ quenches the fluorescence of OFL via static quenching. Upon the introduction of DPA, it interacts with the OFL-Cu²⁺ complex, resulting in an enhanced fluorescence signal from OFL. The assay demonstrated a limit of detection (LOD) of 0.08 µM over a range of 0.6–120 µM, as measured by a spectrofluorometer. The d-PAD was designed for efficient reagent transport through capillary action on paper substrates, allowing for rapid on-site DPA analysis without requiring advanced laboratory equipment. The length of the fluorescent bands on the d-PADs was proportional to the concentration of DPA, providing a simple and effective readout method. With a sensitivity of 0.6 µM, the device shows a strong response to varying DPA concentrations. This distance-based platform offers a straightforward and quantitative approach to result interpretation, making it a promising tool for detecting bacterial spores in real samples. The development and optimization of this paper-based microfluidic assay represent a significant step forward in portable diagnostic technologies.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"65 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4an01393j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Dipicolinic acid (DPA) is a key biomarker of bacterial spores. In this study, we present a novel distance-based paper analytical device (d-PAD) for the fluorescence sensing of DPA. The detection mechanism relies on the complexation of ofloxacin (OFL) with Cu²⁺ ions, where Cu²⁺ quenches the fluorescence of OFL via static quenching. Upon the introduction of DPA, it interacts with the OFL-Cu²⁺ complex, resulting in an enhanced fluorescence signal from OFL. The assay demonstrated a limit of detection (LOD) of 0.08 µM over a range of 0.6–120 µM, as measured by a spectrofluorometer. The d-PAD was designed for efficient reagent transport through capillary action on paper substrates, allowing for rapid on-site DPA analysis without requiring advanced laboratory equipment. The length of the fluorescent bands on the d-PADs was proportional to the concentration of DPA, providing a simple and effective readout method. With a sensitivity of 0.6 µM, the device shows a strong response to varying DPA concentrations. This distance-based platform offers a straightforward and quantitative approach to result interpretation, making it a promising tool for detecting bacterial spores in real samples. The development and optimization of this paper-based microfluidic assay represent a significant step forward in portable diagnostic technologies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过氧氟沙星与 Cu²⁺ 的络合检测双氯喹啉酸的基于长度带荧光的纸质分析装置
二砒啶酸(DPA)是细菌孢子的一种关键生物标志物。在这项研究中,我们提出了一种新型的基于距离的纸分析装置(d-PAD),用于荧光传感 DPA。其检测机制依赖于氧氟沙星(OFL)与 Cu²⁺ 离子的络合,其中 Cu²⁺ 通过静态淬灭作用淬灭氧氟沙星的荧光。引入 DPA 后,DPA 与 OFL-Cu²⁺ 复合物相互作用,从而增强了 OFL 的荧光信号。经分光荧光测定仪测定,在 0.6-120 µM 的范围内,检测限 (LOD) 为 0.08 µM。d-PAD 的设计旨在通过毛细作用在纸质基底上实现高效的试剂传输,从而无需先进的实验室设备即可进行快速的现场 DPA 分析。d-PAD 上荧光带的长度与 DPA 浓度成正比,提供了一种简单有效的读数方法。该装置的灵敏度为 0.6 µM,对不同浓度的 DPA 有强烈的反应。这种基于距离的平台提供了一种直接、定量的结果解读方法,使其成为检测实际样品中细菌孢子的一种很有前途的工具。这种基于纸张的微流控检测方法的开发和优化标志着便携式诊断技术向前迈出了重要一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: The home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences
期刊最新文献
Nanocarbon eco-hydrogel kit: on-site visual metal ion sensing and dye cleanup, advancing the circular economy in environmental remediation Length-band fluorescence-based paper analytical device for detecting dipicolinic acid via ofloxacin complexation with Cu²⁺ β-Cyclodextrin Modified Imidazole Probe Specific Recognition of Organic Acids Based on Nuclear Magnetic Resonance Development and validation of a one-step SMN assay for genetic testing in spinal muscular atrophy via MALDI-TOF MS Stationary Phase Effects in Hydrophilic Interaction Liquid Chromatographic Separation of Oligonucleotides
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1