{"title":"Efficacy of arterial compression hemostasis devices in liver cancer treatment: a systematic review and meta-analysis.","authors":"Handan Liu, Li Yang, Qin Qin, Lijun Cui","doi":"10.1186/s12957-024-03599-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To systematically evaluate the efficacy of arterial compression hemostasis devices after femoral artery puncture interventions for hepatocellular carcinoma (HCC).</p><p><strong>Methods: </strong>We systematically searched 10 electronic databases (PubMed, Scopus, EMBASE, The Cochrane Library, CINAHL, Web of Science, CNKI, Wanfang, VIP, and CBM) up to October 20, 2024, to identify randomized controlled trials (RCTs) of arterial compression hemostasis devices used after HCC interventions through femoral artery puncture. We used the Cochrane risk of bias assessment tool to evaluate the trial quality, and we analyzed the data with Review Manager 5.4 software.</p><p><strong>Results: </strong>17 RCTs involving 2,338 participants met the inclusion criteria. The meta-analysis demonstrated that, compared with conventional manual compression combined with sandbags, the use of arterial compression hemostasis devices significantly shortened the compression hemostasis time [MD = -13.9 min, 95% CI, -14.19 to -12.19; P < 0.00001] and limb immobilization time [MD = -8.79 min, 95% CI, -12.65 to -4.94; P < 0.00001]. Additionally, it significantly reduced the incidence of local bleeding [RR = 0.28, 95% CI, 0.20 to 0.40; P < 0.00001], hematoma formation [RR = 0.29, 95% CI, 0.18 to 0.46; P < 0.00001], skin ecchymosis [RR = 0.25, 95% CI, 0.18 to 0.35; P < 0.00001], dysuria [RR = 0.22, 95% CI, 0.14 to 0.34; P = 0.0002], skin damage [RR = 0.16, 95% CI, 0.05 to 0.54; P = 0.003], backache [RR = 0.28, 95% CI, 0.13 to 0.64; P = 0.002], and pseudoaneurysm [RR = 0.22, 95% CI, 0.10 to 0.51; P = 0.0004].</p><p><strong>Conclusions: </strong>The analysis revealed that arterial compression hemostasis devices significantly reduce hemostasis and immobilization time, as well as vascular complications in liver cancer patients undergoing interventional therapy.</p>","PeriodicalId":23856,"journal":{"name":"World Journal of Surgical Oncology","volume":"22 1","pages":"312"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11590351/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Surgical Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12957-024-03599-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To systematically evaluate the efficacy of arterial compression hemostasis devices after femoral artery puncture interventions for hepatocellular carcinoma (HCC).
Methods: We systematically searched 10 electronic databases (PubMed, Scopus, EMBASE, The Cochrane Library, CINAHL, Web of Science, CNKI, Wanfang, VIP, and CBM) up to October 20, 2024, to identify randomized controlled trials (RCTs) of arterial compression hemostasis devices used after HCC interventions through femoral artery puncture. We used the Cochrane risk of bias assessment tool to evaluate the trial quality, and we analyzed the data with Review Manager 5.4 software.
Results: 17 RCTs involving 2,338 participants met the inclusion criteria. The meta-analysis demonstrated that, compared with conventional manual compression combined with sandbags, the use of arterial compression hemostasis devices significantly shortened the compression hemostasis time [MD = -13.9 min, 95% CI, -14.19 to -12.19; P < 0.00001] and limb immobilization time [MD = -8.79 min, 95% CI, -12.65 to -4.94; P < 0.00001]. Additionally, it significantly reduced the incidence of local bleeding [RR = 0.28, 95% CI, 0.20 to 0.40; P < 0.00001], hematoma formation [RR = 0.29, 95% CI, 0.18 to 0.46; P < 0.00001], skin ecchymosis [RR = 0.25, 95% CI, 0.18 to 0.35; P < 0.00001], dysuria [RR = 0.22, 95% CI, 0.14 to 0.34; P = 0.0002], skin damage [RR = 0.16, 95% CI, 0.05 to 0.54; P = 0.003], backache [RR = 0.28, 95% CI, 0.13 to 0.64; P = 0.002], and pseudoaneurysm [RR = 0.22, 95% CI, 0.10 to 0.51; P = 0.0004].
Conclusions: The analysis revealed that arterial compression hemostasis devices significantly reduce hemostasis and immobilization time, as well as vascular complications in liver cancer patients undergoing interventional therapy.
期刊介绍:
World Journal of Surgical Oncology publishes articles related to surgical oncology and its allied subjects, such as epidemiology, cancer research, biomarkers, prevention, pathology, radiology, cancer treatment, clinical trials, multimodality treatment and molecular biology. Emphasis is placed on original research articles. The journal also publishes significant clinical case reports, as well as balanced and timely reviews on selected topics.
Oncology is a multidisciplinary super-speciality of which surgical oncology forms an integral component, especially with solid tumors. Surgical oncologists around the world are involved in research extending from detecting the mechanisms underlying the causation of cancer, to its treatment and prevention. The role of a surgical oncologist extends across the whole continuum of care. With continued developments in diagnosis and treatment, the role of a surgical oncologist is ever-changing. Hence, World Journal of Surgical Oncology aims to keep readers abreast with latest developments that will ultimately influence the work of surgical oncologists.