A new IGDT-based robust model for day-ahead scheduling of smart power system integrated with compressed air energy storage and dynamic rating of transformers and lines

IF 8.9 2区 工程技术 Q1 ENERGY & FUELS Journal of energy storage Pub Date : 2024-11-28 DOI:10.1016/j.est.2024.114695
Elyar Asadzadeh Aghdam , Sahar Moslemi , Mohammad Sadegh Nakisaee , Mahan Fakhrooeian , Ali Jawad Kadhim Al-Hassanawy , Milad Hadizadeh Masali , Abbas Zare Ghaleh Seyyedi
{"title":"A new IGDT-based robust model for day-ahead scheduling of smart power system integrated with compressed air energy storage and dynamic rating of transformers and lines","authors":"Elyar Asadzadeh Aghdam ,&nbsp;Sahar Moslemi ,&nbsp;Mohammad Sadegh Nakisaee ,&nbsp;Mahan Fakhrooeian ,&nbsp;Ali Jawad Kadhim Al-Hassanawy ,&nbsp;Milad Hadizadeh Masali ,&nbsp;Abbas Zare Ghaleh Seyyedi","doi":"10.1016/j.est.2024.114695","DOIUrl":null,"url":null,"abstract":"<div><div>Growing concerns about climate change have driven power system operators worldwide to utilize wind energy as clean and affordable energy. High penetration of wind energy along with high power consumption of consumers can cause congestion in the transmission network which in turn cause wind spillage, load shedding and high operation cost. Motivated by this challenge, compressed air energy storage (CAES), dynamic transformer rating (DTR) and dynamic line rating (DLR) are three smart technologies that are considered as ways to increase the flexibility of the electrical network and decrease wind spillage and load shedding. With DTR and DLR technologies, the real capacity of transformers and lines is determined which is dependent on weather parameters. Hence, this study proposes a day-ahead scheduling based on the AC power flow model for smart power system taking CAES, DLR and DTR into account. The aim of this model is to minimize load shedding, wind spillage, total cost and emissions. Uncertainties of wind energy (which has a great impact on day-ahead scheduling and capacity of lines with DLR) and electrical load, are handled through an improved form of the information gap decision theory (IGDT), hereafter called weighted IGDT (WIGDT)-based robust model. The effectiveness of the introduced method is evaluated by testing on IEEE 24-bus system. According to obtained results, simultaneous used of CAES, DTR and DLR can reduce wind spillage, load shedding, emission and operation cost and also improve the voltage profile.</div></div>","PeriodicalId":15942,"journal":{"name":"Journal of energy storage","volume":"105 ","pages":"Article 114695"},"PeriodicalIF":8.9000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of energy storage","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352152X24042816","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Growing concerns about climate change have driven power system operators worldwide to utilize wind energy as clean and affordable energy. High penetration of wind energy along with high power consumption of consumers can cause congestion in the transmission network which in turn cause wind spillage, load shedding and high operation cost. Motivated by this challenge, compressed air energy storage (CAES), dynamic transformer rating (DTR) and dynamic line rating (DLR) are three smart technologies that are considered as ways to increase the flexibility of the electrical network and decrease wind spillage and load shedding. With DTR and DLR technologies, the real capacity of transformers and lines is determined which is dependent on weather parameters. Hence, this study proposes a day-ahead scheduling based on the AC power flow model for smart power system taking CAES, DLR and DTR into account. The aim of this model is to minimize load shedding, wind spillage, total cost and emissions. Uncertainties of wind energy (which has a great impact on day-ahead scheduling and capacity of lines with DLR) and electrical load, are handled through an improved form of the information gap decision theory (IGDT), hereafter called weighted IGDT (WIGDT)-based robust model. The effectiveness of the introduced method is evaluated by testing on IEEE 24-bus system. According to obtained results, simultaneous used of CAES, DTR and DLR can reduce wind spillage, load shedding, emission and operation cost and also improve the voltage profile.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于 IGDT 的新鲁棒性模型,用于集成压缩空气储能和变压器与线路动态额定值的智能电力系统的日前调度
人们对气候变化的担忧与日俱增,促使全球电力系统运营商将风能作为清洁、经济的能源加以利用。风能的高渗透率和用户的高耗电量会造成输电网络的拥堵,进而导致风能溢出、甩负荷和高运行成本。在这一挑战的推动下,压缩空气储能(CAES)、动态变压器额定值(DTR)和动态线路额定值(DLR)这三种智能技术被认为是提高电网灵活性、减少风电溢出和甩负荷的方法。利用 DTR 和 DLR 技术,变压器和线路的实际容量取决于天气参数。因此,本研究提出了一种基于交流电流模型的智能电力系统日前调度方法,其中考虑了 CAES、DLR 和 DTR。该模型的目的是最大限度地减少甩负荷、风电溢出、总成本和排放。风能(对日前调度和带 DLR 线路的容量有很大影响)和电力负荷的不确定性通过信息差距决策理论 (IGDT) 的改进形式(以下称为基于加权 IGDT (WIGDT) 的鲁棒模型)来处理。通过对 IEEE 24 总线系统进行测试,评估了所引入方法的有效性。结果表明,同时使用 CAES、DTR 和 DLR 可以减少风溢出、甩负荷、排放和运行成本,还能改善电压曲线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of energy storage
Journal of energy storage Energy-Renewable Energy, Sustainability and the Environment
CiteScore
11.80
自引率
24.50%
发文量
2262
审稿时长
69 days
期刊介绍: Journal of energy storage focusses on all aspects of energy storage, in particular systems integration, electric grid integration, modelling and analysis, novel energy storage technologies, sizing and management strategies, business models for operation of storage systems and energy storage developments worldwide.
期刊最新文献
Editorial Board Synthesis and fabrication of tetragonal copper chromite nanospheres for usage as the cathode material in asymmetric supercapacitors Restricted growth of polyaniline nanofiber arrays between holey graphene sheets on carbon cloth towards improved charge storage capacity Modified poly(vinylidene fluoride) polymer binder enables ultrathin sulfide solid electrolyte membrane for all-solid-state batteries In-situ micro-battery etching induced 3D Zn with amorphous interfacial coating for high-stable Zn metal batteries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1