{"title":"Improved fractional order control with virtual inertia provision methodology for electric vehicle batteries in modern multi-microgrid energy systems","authors":"Wessam A. Hafez ,&nbsp;Mokhtar Aly ,&nbsp;Emad A. Mohamed ,&nbsp;Nadia A. Nagem","doi":"10.1016/j.est.2024.114582","DOIUrl":null,"url":null,"abstract":"<div><div>Providing inertia in modern electrical power grids has become a highly demanding task to mitigate reduced power system inertia of renewable energy sources (RES) based power grids. To mitigate the reduced inertia-related problems and consequences, this paper presents improved FOCs for achieving load frequency control (LFC) and the virtual inertia control (VIC) provision of electric vehicles (EVs) lithium-ion batteries. The proposed method includes a twofold contribution using a new hybrid FOC method and an optimum control parameter design method. An innovative hybrid controller is proposed by merging the characteristics of FOPID and TID methods with a fractional filtering stage, leading to hybrid tilt plus FOC integrator-derivative terms. From the VIC side, the TID is proposed to provide a fast response to lithium-ion batteries of the already available EVs. Furthermore, a metaheuristic-based design method is proposed to simultaneously determine the best control parameters set and to facilitate the design procedures using the recently presented powerful growth optimization algorithm (GO). The two interconnected areas case study with high-RES penetration is suggested for testing and investigating the new proposed controller. The results include performance evaluations and comparisons at various expected model uncertainties, renewable energy intermittency, and parametric variations. For instance, the proposed VIC method has a minimized ISE after 28 iterations of 0.001 compared to 0.003 with conventional VIC, and 0.004 without VIC. Thence,the proposed controller achieves more accurate frequency tracking with reduced deviations and fluctuations and exhibits greater robustness compared to previous controllers used in all case studies.</div></div>","PeriodicalId":15942,"journal":{"name":"Journal of energy storage","volume":"106 ","pages":"Article 114582"},"PeriodicalIF":8.9000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of energy storage","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352152X24041689","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Providing inertia in modern electrical power grids has become a highly demanding task to mitigate reduced power system inertia of renewable energy sources (RES) based power grids. To mitigate the reduced inertia-related problems and consequences, this paper presents improved FOCs for achieving load frequency control (LFC) and the virtual inertia control (VIC) provision of electric vehicles (EVs) lithium-ion batteries. The proposed method includes a twofold contribution using a new hybrid FOC method and an optimum control parameter design method. An innovative hybrid controller is proposed by merging the characteristics of FOPID and TID methods with a fractional filtering stage, leading to hybrid tilt plus FOC integrator-derivative terms. From the VIC side, the TID is proposed to provide a fast response to lithium-ion batteries of the already available EVs. Furthermore, a metaheuristic-based design method is proposed to simultaneously determine the best control parameters set and to facilitate the design procedures using the recently presented powerful growth optimization algorithm (GO). The two interconnected areas case study with high-RES penetration is suggested for testing and investigating the new proposed controller. The results include performance evaluations and comparisons at various expected model uncertainties, renewable energy intermittency, and parametric variations. For instance, the proposed VIC method has a minimized ISE after 28 iterations of 0.001 compared to 0.003 with conventional VIC, and 0.004 without VIC. Thence,the proposed controller achieves more accurate frequency tracking with reduced deviations and fluctuations and exhibits greater robustness compared to previous controllers used in all case studies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
现代多微网能源系统中电动汽车电池的改进分数阶虚拟惯性控制方法
在现代电网中提供惯性已成为一项要求很高的任务,以减轻基于可再生能源(RES)的电网的电力系统惯性。为了减少惯性相关的问题和后果,本文提出了改进的FOCs,用于实现电动汽车锂离子电池的负载频率控制(LFC)和虚拟惯性控制(VIC)。该方法包括一种新的混合FOC方法和一种最优控制参数设计方法的双重贡献。将FOPID和TID方法的特点与分数阶滤波相结合,提出了一种新颖的混合控制器,实现了倾斜和FOC积分导数项的混合控制。从VIC方面来看,TID被提议为现有电动汽车的锂离子电池提供快速响应。此外,提出了一种基于元启发式的设计方法,可以同时确定最佳控制参数集,并使用最近提出的强大的生长优化算法(GO)简化设计过程。提出了两个互连区域的高分辨率穿透案例研究,以测试和研究新提出的控制器。结果包括在各种预期模型不确定性、可再生能源间歇性和参数变化下的性能评估和比较。例如,与传统VIC方法的0.003和没有VIC方法的0.004相比,所提出的VIC方法在28次迭代后的ISE最小值为0.001。因此,与所有案例研究中使用的以前的控制器相比,所提议的控制器实现了更准确的频率跟踪,偏差和波动减少,并表现出更强的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of energy storage
Journal of energy storage Energy-Renewable Energy, Sustainability and the Environment
CiteScore
11.80
自引率
24.50%
发文量
2262
审稿时长
69 days
期刊介绍: Journal of energy storage focusses on all aspects of energy storage, in particular systems integration, electric grid integration, modelling and analysis, novel energy storage technologies, sizing and management strategies, business models for operation of storage systems and energy storage developments worldwide.
期刊最新文献
Tailoring hydrogen-bond networks in NaCH₃COO·3H₂O phase change materials: Lotus root starch and carbon nanofiber synergy toward efficient thermal storage Graphene-enhanced thermally flexible polyethylene glycol-based phase change materials for thermal energy storage and management Enhanced harmonic reduction and energy optimization in grid-connected photovoltaic-battery systems for improved power quality Iron–nitrogen-doped eggshell carbon microsphere-encapsulated hollow nanoparticle catalysts for enhanced oxygen reduction reaction in zinc–air batteries Hydrofluoric acid free synthesis of Ti3C2Tx-Fe3O4 composite anode coupled with high voltage NaxMn3O7 cathode for 2.2 V supercapacitors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1