Distribution of the dose response in a silicone-based radio-fluorogenic dosimeter and FWT-60 irradiated with monochromatic low-energy X-rays

IF 1.6 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY Radiation Measurements Pub Date : 2024-11-28 DOI:10.1016/j.radmeas.2024.107347
Seiko Nakagawa , Takuya Maeyama , Akinari Yokoya , Maki Ohara , Noriko Usami
{"title":"Distribution of the dose response in a silicone-based radio-fluorogenic dosimeter and FWT-60 irradiated with monochromatic low-energy X-rays","authors":"Seiko Nakagawa ,&nbsp;Takuya Maeyama ,&nbsp;Akinari Yokoya ,&nbsp;Maki Ohara ,&nbsp;Noriko Usami","doi":"10.1016/j.radmeas.2024.107347","DOIUrl":null,"url":null,"abstract":"<div><div>In a previous work, we studied the electron spin resonance imaging of the alanine dosimeter irradiated with 0.36–1.8 kGy of 4- and 7-keV monochromatic X-rays and visualized the distribution of alanine radicals as a function of the penetration depth of the X-rays. Herein, the dose-response profile, as a function of the penetration depth, of a silicone-based gel dosimeter and FWT-60 film dosimeter was studied for comparison with the alanine dosimeter. A silicone-based gel dosimeter using dihydrorhodamine 6G (DHR6G) as a fluorescence probe was irradiated with 0–45 Gy of 10-keV monochromatic X-rays. The dose-response profile of the fluorescence was then investigated in detail to demonstrate the properties of low-energy X-ray irradiation. The fluorescence intensity at the surface was less than that inside when irradiated with a higher dose. The total fluorescence intensity per unit dose decreased with the increasing dose. These results were almost the same as those for the alanine dosimeter. At the surface, many of the radicals produced in the silicone elastomer would be lost due to radical-radical recombination before reacting with DHR6G owing to the high linear energy transfer nature of the low-energy X-ray irradiation. The FWT-60 film dosimeter was irradiated with 0.8–10 kGy of 2- and 4-keV monochromatic X-rays. For the FWT-60 film, the dose-response linearly increased with the dose, although its efficiency was far lower than that of the gel dosimeter. Additionally, the slope of the dose-response decreased with the decreasing photon energy. Some of the precursor molecules for the pigment will be directly ionized, transforming into the coloring agent in the FWT-60 film. Finally, the reaction mechanism to produce the pigment in each dosimeter would affect the dose-response properties of irradiation via low-energy X-rays.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"181 ","pages":"Article 107347"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448724002956","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In a previous work, we studied the electron spin resonance imaging of the alanine dosimeter irradiated with 0.36–1.8 kGy of 4- and 7-keV monochromatic X-rays and visualized the distribution of alanine radicals as a function of the penetration depth of the X-rays. Herein, the dose-response profile, as a function of the penetration depth, of a silicone-based gel dosimeter and FWT-60 film dosimeter was studied for comparison with the alanine dosimeter. A silicone-based gel dosimeter using dihydrorhodamine 6G (DHR6G) as a fluorescence probe was irradiated with 0–45 Gy of 10-keV monochromatic X-rays. The dose-response profile of the fluorescence was then investigated in detail to demonstrate the properties of low-energy X-ray irradiation. The fluorescence intensity at the surface was less than that inside when irradiated with a higher dose. The total fluorescence intensity per unit dose decreased with the increasing dose. These results were almost the same as those for the alanine dosimeter. At the surface, many of the radicals produced in the silicone elastomer would be lost due to radical-radical recombination before reacting with DHR6G owing to the high linear energy transfer nature of the low-energy X-ray irradiation. The FWT-60 film dosimeter was irradiated with 0.8–10 kGy of 2- and 4-keV monochromatic X-rays. For the FWT-60 film, the dose-response linearly increased with the dose, although its efficiency was far lower than that of the gel dosimeter. Additionally, the slope of the dose-response decreased with the decreasing photon energy. Some of the precursor molecules for the pigment will be directly ionized, transforming into the coloring agent in the FWT-60 film. Finally, the reaction mechanism to produce the pigment in each dosimeter would affect the dose-response properties of irradiation via low-energy X-rays.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
期刊最新文献
Optimization of subcellular boron distribution measurement using UV-C imprint and neutron autoradiography in boron neutron capture therapy Distribution of the dose response in a silicone-based radio-fluorogenic dosimeter and FWT-60 irradiated with monochromatic low-energy X-rays Performances of the RadPro myOSL 4.0 whole body dosimeter Photon energy estimation in diagnostic radiology using OSL dosimeters: Experimental validation and Monte Carlo simulations Review of real time 2D dosimetry in external radiotherapy: Advancements and techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1