Polycatechol coated cigarette filter as a sorbent for microextraction by packed sorbent of acidic non-steroidal anti-inflammatory drugs (NSAIDs) from wastewater samples

IF 4.9 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchemical Journal Pub Date : 2024-11-29 DOI:10.1016/j.microc.2024.112298
Farah Al-Hammashi, Fariborz Momenbeik
{"title":"Polycatechol coated cigarette filter as a sorbent for microextraction by packed sorbent of acidic non-steroidal anti-inflammatory drugs (NSAIDs) from wastewater samples","authors":"Farah Al-Hammashi,&nbsp;Fariborz Momenbeik","doi":"10.1016/j.microc.2024.112298","DOIUrl":null,"url":null,"abstract":"<div><div>In this study, we employed microextraction by packed sorbent (MEPS) using polycatechol-coated cigarette filters (PCCFs) as a sorbent to extract acidic non-steroidal anti-inflammatory drugs (NSAIDs) from water samples, followed by high-performance liquid chromatographic analysis. The formation of coating on cigarette filter was confirmed by Fourier transform infrared (FT-IR) spectroscopy, UV–vis diffuse reflectance spectroscopy (DRS) and scanning electron microscopy (SEM). The effect of coating parameters on extraction efficiency of acidic NASIDs were investigated and 106.0 mg of Na<sub>2</sub>CO<sub>3</sub>, 30.0 mg of catechol and 3 h coating time were selected as optimum conditions. Additionally, other factors affecting the analyte extraction efficiency were optimized including a sample solution pH of 2.0, 700.0 µL of methanol as the elution solvent, 3 sorption cycles, 2 desorption cycles, and a 1.5 ml sample volume. Under the optimum conditions the calibration curves for all three analytes were draw and the analytical performance parameters including linear dynamic range (50.0–1000.0 µg.L<sup>−1</sup> for naproxen and diclofenac and 100.0–500.0 µg.L<sup>−1</sup> for ibuprofen) with R<sup>2</sup> &gt; 0.9982, limit of detection (LOD &lt; 45.3 µg.L<sup>−1</sup>), precision (RSD% &lt; 6.5), accuracy (recovery% &gt; 90.1) and enrichment factor (EF &gt; 2.7) were evaluated. Finally, this method was successfully used to extract and determine the amount of selected acidic NSAIDs in wastewater samples. The sorbent was cheap, easily prepared, efficient, and even reusable.</div></div>","PeriodicalId":391,"journal":{"name":"Microchemical Journal","volume":"208 ","pages":"Article 112298"},"PeriodicalIF":4.9000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchemical Journal","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0026265X2402410X","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we employed microextraction by packed sorbent (MEPS) using polycatechol-coated cigarette filters (PCCFs) as a sorbent to extract acidic non-steroidal anti-inflammatory drugs (NSAIDs) from water samples, followed by high-performance liquid chromatographic analysis. The formation of coating on cigarette filter was confirmed by Fourier transform infrared (FT-IR) spectroscopy, UV–vis diffuse reflectance spectroscopy (DRS) and scanning electron microscopy (SEM). The effect of coating parameters on extraction efficiency of acidic NASIDs were investigated and 106.0 mg of Na2CO3, 30.0 mg of catechol and 3 h coating time were selected as optimum conditions. Additionally, other factors affecting the analyte extraction efficiency were optimized including a sample solution pH of 2.0, 700.0 µL of methanol as the elution solvent, 3 sorption cycles, 2 desorption cycles, and a 1.5 ml sample volume. Under the optimum conditions the calibration curves for all three analytes were draw and the analytical performance parameters including linear dynamic range (50.0–1000.0 µg.L−1 for naproxen and diclofenac and 100.0–500.0 µg.L−1 for ibuprofen) with R2 > 0.9982, limit of detection (LOD < 45.3 µg.L−1), precision (RSD% < 6.5), accuracy (recovery% > 90.1) and enrichment factor (EF > 2.7) were evaluated. Finally, this method was successfully used to extract and determine the amount of selected acidic NSAIDs in wastewater samples. The sorbent was cheap, easily prepared, efficient, and even reusable.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchemical Journal
Microchemical Journal 化学-分析化学
CiteScore
8.70
自引率
8.30%
发文量
1131
审稿时长
1.9 months
期刊介绍: The Microchemical Journal is a peer reviewed journal devoted to all aspects and phases of analytical chemistry and chemical analysis. The Microchemical Journal publishes articles which are at the forefront of modern analytical chemistry and cover innovations in the techniques to the finest possible limits. This includes fundamental aspects, instrumentation, new developments, innovative and novel methods and applications including environmental and clinical field. Traditional classical analytical methods such as spectrophotometry and titrimetry as well as established instrumentation methods such as flame and graphite furnace atomic absorption spectrometry, gas chromatography, and modified glassy or carbon electrode electrochemical methods will be considered, provided they show significant improvements and novelty compared to the established methods.
期刊最新文献
Competitive adsorption of two phenolic pollutants compounds using a novel biosorbent: Analytics (HPLC), Statistical (experimental design), and theoretical studies (DFT) Strategy of mass defect filter combined with characteristic fragment analysis for the chemical profiling of Dictamnus dasycarpus Turcz. From multiple regions A comprehensive review on niclosamide detection in foodstuffs and pharmaceutical preparations: Diverse analytical approaches and emerging techniques Polycatechol coated cigarette filter as a sorbent for microextraction by packed sorbent of acidic non-steroidal anti-inflammatory drugs (NSAIDs) from wastewater samples Detection of parvovirus B19 genomic fragments using an electrochemical biosensor based on argonaute-assisted silver metallization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1