Electrochemical sensor based on molecularly imprinted polypyrrole-MWCNTs-OH/covalent organic framework for the detection of ofloxacin in water

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2024-12-03 DOI:10.1007/s00604-024-06860-w
Lijuan Huang, Yuan Luo, Xulin Li, Juan Wu, Qian Long, Li Zheng, Wenlong Liao, Huiming Li, Lingpu Jia, Kunping Liu
{"title":"Electrochemical sensor based on molecularly imprinted polypyrrole-MWCNTs-OH/covalent organic framework for the detection of ofloxacin in water","authors":"Lijuan Huang,&nbsp;Yuan Luo,&nbsp;Xulin Li,&nbsp;Juan Wu,&nbsp;Qian Long,&nbsp;Li Zheng,&nbsp;Wenlong Liao,&nbsp;Huiming Li,&nbsp;Lingpu Jia,&nbsp;Kunping Liu","doi":"10.1007/s00604-024-06860-w","DOIUrl":null,"url":null,"abstract":"<div><p>A platform was developed to accurately detect the content of ofloxacin (OFX) based on molecularly imprinted polypyrrole-MWCNTs-OH/1,3,5-Tris(4-aminophenyl) benzene (TAPB)-2,5-dimethoxybenzene-1,4-dicarboxaldehyde (DMTP)-covalent organic framework (MIP-MWCNTs-OH/COF)–modified glassy carbon electrode (GCE) sensor (MIP-MWCNTs-OH/COF/GCE). The complex of MWCNTs-OH and COF synergistically enhanced the active area and electrochemical signal, based on which a molecularly imprinted membrane was polymerized on its surface to further improve the selectivity. Under optimized conditions, the prepared MIP-MWCNTs-OH/COF/GCE sensor exhibited strong detection performance to OFX in a linear range 1.969 × 10<sup>−11</sup>–9.619 × 10<sup>−9</sup> M with the limit of detection (LOD, 3S/N) of 4.989 × 10<sup>−12</sup> M, excellent selectivity, stability, and reproducibility. Furthermore, the MIP-MWCNTs-OH/COF/GCE sensor can be successfully applied to the detection of OFX in lake water and eye drops with a relative standard deviation (RSD) of less than 4.95%, indicating its high potential in practical applications.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 1","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06860-w","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A platform was developed to accurately detect the content of ofloxacin (OFX) based on molecularly imprinted polypyrrole-MWCNTs-OH/1,3,5-Tris(4-aminophenyl) benzene (TAPB)-2,5-dimethoxybenzene-1,4-dicarboxaldehyde (DMTP)-covalent organic framework (MIP-MWCNTs-OH/COF)–modified glassy carbon electrode (GCE) sensor (MIP-MWCNTs-OH/COF/GCE). The complex of MWCNTs-OH and COF synergistically enhanced the active area and electrochemical signal, based on which a molecularly imprinted membrane was polymerized on its surface to further improve the selectivity. Under optimized conditions, the prepared MIP-MWCNTs-OH/COF/GCE sensor exhibited strong detection performance to OFX in a linear range 1.969 × 10−11–9.619 × 10−9 M with the limit of detection (LOD, 3S/N) of 4.989 × 10−12 M, excellent selectivity, stability, and reproducibility. Furthermore, the MIP-MWCNTs-OH/COF/GCE sensor can be successfully applied to the detection of OFX in lake water and eye drops with a relative standard deviation (RSD) of less than 4.95%, indicating its high potential in practical applications.

Graphical Abstract

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于分子印迹聚吡咯- mwcnts - oh /共价有机骨架的电化学传感器检测水中氧氟沙星
基于分子印迹聚吡咯- mwcnts - oh /1,3,5-三(4-氨基苯基)苯(TAPB)-2,5-二甲氧基苯-1,4-二甲醛(DMTP)-共价有机框架(MIP-MWCNTs-OH/COF) -修饰玻璃碳电极(GCE)传感器(MIP-MWCNTs-OH/COF/GCE),建立了氧氟沙星(OFX)含量准确检测平台。MWCNTs-OH和COF配合物协同增强了活性区域和电化学信号,在此基础上在其表面聚合分子印迹膜,进一步提高了选择性。在优化条件下,制备的MIP-MWCNTs-OH/COF/GCE传感器在1.969 × 10−11-9.619 × 10−9 M线性范围内对OFX具有较强的检测性能,检出限(LOD, 3S/N)为4.989 × 10−12 M,具有良好的选择性、稳定性和重复性。此外,MIP-MWCNTs-OH/COF/GCE传感器可成功用于湖水和眼药水中OFX的检测,相对标准偏差(RSD)小于4.95%,具有较高的实际应用潜力。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
Potential biomarkers and their recent applications ofr point-of-care biosensors for the diagnosis of malaria. High-sensitivity SERS nanosensor for precise in situ tracking of caspase-1 during pyroptosis in macrophages. A novel surface plasmon resonance sensor development for broflanilide determination using molecularly imprinted polymers and sulphur doped reduced graphene oxide@nickel sulfide nanoparticles. Built-in thiol mesoporous carbon immunosensor to detect carcinoembryonic antigen in human serum. Aptamer-modified metal-organic framework fiber network as a selective and recyclable affinity pretreatment column for aflatoxin B1 enrichment in feed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1