Evaluating performance and quality of a fast multi-contrast scan in routine brain MRI

IF 2.3 4区 医学 Q3 CLINICAL NEUROLOGY Journal of Neuroimaging Pub Date : 2024-11-30 DOI:10.1111/jon.13248
Eugene Milshteyn, Harry Griffin, Yi Shuen Chang, Ibraheem Shaikh, Tim Sprenger, Stefan Skare, Christopher J. Maclellan, Salil Soman
{"title":"Evaluating performance and quality of a fast multi-contrast scan in routine brain MRI","authors":"Eugene Milshteyn,&nbsp;Harry Griffin,&nbsp;Yi Shuen Chang,&nbsp;Ibraheem Shaikh,&nbsp;Tim Sprenger,&nbsp;Stefan Skare,&nbsp;Christopher J. Maclellan,&nbsp;Salil Soman","doi":"10.1111/jon.13248","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background and Purpose</h3>\n \n <p>Neuromix is a fast, motion robust multi-contrast sequence capable of providing all diagnostic contrasts in ∼3.5 minutes. However, more evaluation is needed across the various contrasts compared to gold standard, optimized sequences routinely used in the clinic. The goal of this study was to prospectively determine how NeuroMix performs in the clinical setting compared to routine clinical MRI.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>NeuroMix and routine clinical MRI sequences were acquired on a 3 Tesla clinical scanner for 39 patients clinically indicated for brain MRI. Three radiologists were asked to assess the diagnostic confidence of NeuroMix compared to the routine MRI using a series of questions. Signal-to-noise and contrast-to-noise ratios (SNR and CNR) were assessed for NeuroMix. Fleiss’ free-marginal multirater kappa was calculated for the qualitative assessment performed by the radiologists.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Radiologists were comfortable substituting or reading some of the NeuroMix sequences in place of the corresponding conventional sequence for some contrasts, including diffusion-weighted imaging, single-shot T<sub>2</sub>, and susceptibility-weighted imaging. The image quality, SNR, and CNR allowed the radiologists to visualize anatomy and pathology on NeuroMix images. There was no significant difference between coefficient of variation for the apparent diffusion coefficient maps (<i>p</i> = .084).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Analysis revealed both positives and some pitfalls of NeuroMix. However, these results indicate Neuromix as having the capability to be a backup sequence in case artifacts are present in routine sequences, or potentially a replacement for some contrasts altogether.</p>\n </section>\n </div>","PeriodicalId":16399,"journal":{"name":"Journal of Neuroimaging","volume":"35 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuroimaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jon.13248","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Purpose

Neuromix is a fast, motion robust multi-contrast sequence capable of providing all diagnostic contrasts in ∼3.5 minutes. However, more evaluation is needed across the various contrasts compared to gold standard, optimized sequences routinely used in the clinic. The goal of this study was to prospectively determine how NeuroMix performs in the clinical setting compared to routine clinical MRI.

Methods

NeuroMix and routine clinical MRI sequences were acquired on a 3 Tesla clinical scanner for 39 patients clinically indicated for brain MRI. Three radiologists were asked to assess the diagnostic confidence of NeuroMix compared to the routine MRI using a series of questions. Signal-to-noise and contrast-to-noise ratios (SNR and CNR) were assessed for NeuroMix. Fleiss’ free-marginal multirater kappa was calculated for the qualitative assessment performed by the radiologists.

Results

Radiologists were comfortable substituting or reading some of the NeuroMix sequences in place of the corresponding conventional sequence for some contrasts, including diffusion-weighted imaging, single-shot T2, and susceptibility-weighted imaging. The image quality, SNR, and CNR allowed the radiologists to visualize anatomy and pathology on NeuroMix images. There was no significant difference between coefficient of variation for the apparent diffusion coefficient maps (p = .084).

Conclusions

Analysis revealed both positives and some pitfalls of NeuroMix. However, these results indicate Neuromix as having the capability to be a backup sequence in case artifacts are present in routine sequences, or potentially a replacement for some contrasts altogether.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估常规脑MRI快速多对比扫描的性能和质量。
背景和目的:Neuromix是一种快速、运动鲁棒的多对比序列,能够在约3.5分钟内提供所有诊断对比。然而,与临床常规使用的金标准优化序列相比,需要对各种对比进行更多的评估。本研究的目的是前瞻性地确定与常规临床MRI相比,NeuroMix在临床环境中的表现。方法:对39例临床表现为脑MRI的患者,在3特斯拉临床扫描仪上获取NeuroMix和常规临床MRI序列。三名放射科医生被要求通过一系列问题来评估NeuroMix与常规MRI相比的诊断可信度。评估NeuroMix的信噪比和噪声对比比(SNR和CNR)。计算Fleiss的自由边际多因子kappa,以供放射科医生进行定性评估。结果:放射科医生可以轻松地替换或读取一些NeuroMix序列来代替相应的常规序列进行一些对比,包括弥散加权成像、单次T2和敏感性加权成像。图像质量、信噪比和CNR使放射科医生能够在NeuroMix图像上可视化解剖和病理。表观扩散系数图的变异系数差异无统计学意义(p = 0.084)。结论:分析显示了NeuroMix的优点和一些缺陷。然而,这些结果表明,在常规序列中存在伪影的情况下,Neuromix有能力成为备用序列,或者可能完全替代某些对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Neuroimaging
Journal of Neuroimaging 医学-核医学
CiteScore
4.70
自引率
0.00%
发文量
117
审稿时长
6-12 weeks
期刊介绍: Start reading the Journal of Neuroimaging to learn the latest neurological imaging techniques. The peer-reviewed research is written in a practical clinical context, giving you the information you need on: MRI CT Carotid Ultrasound and TCD SPECT PET Endovascular Surgical Neuroradiology Functional MRI Xenon CT and other new and upcoming neuroscientific modalities.The Journal of Neuroimaging addresses the full spectrum of human nervous system disease, including stroke, neoplasia, degenerating and demyelinating disease, epilepsy, tumors, lesions, infectious disease, cerebral vascular arterial diseases, toxic-metabolic disease, psychoses, dementias, heredo-familial disease, and trauma.Offering original research, review articles, case reports, neuroimaging CPCs, and evaluations of instruments and technology relevant to the nervous system, the Journal of Neuroimaging focuses on useful clinical developments and applications, tested techniques and interpretations, patient care, diagnostics, and therapeutics. Start reading today!
期刊最新文献
Real-Time 2D Phase-Contrast MRI to Assess Cardiac- and Respiratory-Driven CSF Movement in Normal Pressure Hydrocephalus. Functional Connectivity to the Amygdala in the Neonate Is Impacted by the Maternal Anxiety Level During Pregnancy. Middle Cerebral Artery M2 Occlusions: Impact of Segment Dominance and Benefit of Direct Aspiration for the First-Pass Effect. Brain MRI Detection of an Abnormal Peak Width of Skeletonized Mean Diffusivity in REM Sleep Behavior Disorder. Impact of Pediatric Posterior Fossa Tumor Treatments on Working Memory Tracts Using Resting-State fMRI and Tractography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1