{"title":"Preclinical validation of a metasurface-inspired conformal elliptical-cylinder resonator for wrist MRI at 1.5 T.","authors":"Yakui Wang, Zhonghai Chi, Yi Yi, Yingyi Qi, Xinxin Li, Qian Zhao, Zhuozhao Zheng","doi":"10.1016/j.mri.2024.110291","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To design a metasurface-inspired conformal elliptical-cylinder resonator (MICER) for wrist magnetic resonance imaging at 1.5 T and evaluate its potential for clinical applications.</p><p><strong>Methods: </strong>An electromagnetic simulation was used to characterize the effect of MICER on radio frequency fields. A phantom and 14 wrists from 7 healthy volunteers were examined using a 1.5 T MRI system. The examination included T1-weighted spin echo, fat-saturation proton density-weighted fast spin echo, and three-dimensional T1-weighted gradient echo sequences. All scans were repeated using two methods: MICER combined with the spinal coil, which is a surface coil built-in examination table, and the 12-channel wrist array coil, to receive signals. Image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and the differences between the two methods were compared using a paired Student's t-test.</p><p><strong>Results: </strong>In the phantom study, the image obtained with MICER had a higher SNR compared to the image obtained with the 12-channel wrist coil. Almost all wrist tissues showed a higher SNR on the images obtained with MICER than on the images obtained with the 12-channel wrist coil (P < 0.05). And the CNR between wrist tissues on images obtained with MICER was higher than that obtained with the 12-channel wrist coil (P < 0.05).</p><p><strong>Conclusions: </strong>The quality of the MRI using MICER is superior to that of the commercially available 12-channel wrist coil, indicating its potential value for clinical practice.</p>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":" ","pages":"110291"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.mri.2024.110291","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To design a metasurface-inspired conformal elliptical-cylinder resonator (MICER) for wrist magnetic resonance imaging at 1.5 T and evaluate its potential for clinical applications.
Methods: An electromagnetic simulation was used to characterize the effect of MICER on radio frequency fields. A phantom and 14 wrists from 7 healthy volunteers were examined using a 1.5 T MRI system. The examination included T1-weighted spin echo, fat-saturation proton density-weighted fast spin echo, and three-dimensional T1-weighted gradient echo sequences. All scans were repeated using two methods: MICER combined with the spinal coil, which is a surface coil built-in examination table, and the 12-channel wrist array coil, to receive signals. Image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and the differences between the two methods were compared using a paired Student's t-test.
Results: In the phantom study, the image obtained with MICER had a higher SNR compared to the image obtained with the 12-channel wrist coil. Almost all wrist tissues showed a higher SNR on the images obtained with MICER than on the images obtained with the 12-channel wrist coil (P < 0.05). And the CNR between wrist tissues on images obtained with MICER was higher than that obtained with the 12-channel wrist coil (P < 0.05).
Conclusions: The quality of the MRI using MICER is superior to that of the commercially available 12-channel wrist coil, indicating its potential value for clinical practice.
期刊介绍:
Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.